background image

 

      Return Procedure 

Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued. 
Package must be clearly labeled with a Return Authorization Number (RMA number). Products returned 
without an RMA number will be refused. Highlite will not accept the returned goods or any responsibility. 
Call Highlite 0031-455667723 or mail 

[email protected]

 and request an RMA prior to shipping the fixture. 

Be prepared to provide the model number, serial number and a brief description of the cause for the 
return. Be sure to properly pack fixture, any shipping damage resulting from inadequate packaging is the 
customer’s responsibility. Highlite reserves the right to use its own discretion to repair or replace 
product(s). As a suggestion, proper UPS packing or double-boxing is always a safe method to use. 
 

Note: If you are given an RMA number, please include the following information on a piece of paper 
inside the box: 

1) Your name 
2) Your address 
3) Your phone number 
4) A brief description of the symptoms 
 
 

Claims 

The client has the obligation to check the delivered goods immediately upon delivery for any short-
comings and/or visible defects, or perform this check after our announcement that the goods are at their 
disposal. Damage incurred in shipping is the responsibility of the shipper; therefore the damage must be 
reported to the carrier upon receipt of merchandise. 
 It is the customer's responsibility to notify and submit claims with the shipper in the event that a fixture is 
damaged due to shipping. Transportation damage has to be reported to us within one day after receipt 
of the delivery.  
Any return shipment has to be made post-paid at all times. Return shipments must be accompanied with 
a letter defining the reason for return shipment. Non-prepaid return shipments will be refused, unless 
otherwise agreed in writing. 
Complaints against us must be made known in writing or by fax within 10 working days after receipt of the 
invoice. After this period complaints will not be handled anymore. 
Complaints will only then be considered if the client has so far complied with all parts of the agreement, 
regardless of the agreement of which the obligation is resulting. 
 

 
 
 
 
 
 

Summary of Contents for quadro flower v2

Page 1: ...Quadro Flower V2 ORDERCODE 43028...

Page 2: ...n and manufacture professional light equipment for the entertainment industry New products are being launched regularly We work hard to keep you our customer satisfied For more information iwant showt...

Page 3: ...res and Overview Backside Installation Set Up and Operation Control Modes One Quadro Flower Custom Mode One Quadro Flower Sound Control Multiple Quadro Flowers Master Slave control Multiple Quadro Flo...

Page 4: ...ng on this lifespan expectancy is of a higher priority place care in providing for lower operational temperatures This may include climatic environmental and the reduction of overall projection intens...

Page 5: ...the power cord is never crimped or damaged Check the device and the power cord from time to time If the external cable is damaged it has to be replaced by a qualified technician If the lens is obviou...

Page 6: ...ation yourself Always let the installation be carried out by an authorized dealer Procedure If the Quadro Flower is lowered from the ceiling or high joists professional trussing systems have to be use...

Page 7: ...description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this check after our ann...

Page 8: ...mpact strong metal housing Power consumption 40 Watt Beam angle 15 Light source 256 LEDs 96 Red 96 Green 64 Blue Music controlled via built in microphone Operating Modes built in programs Auto run DMX...

Page 9: ...t Up and Operation Before plugging the unit in always make sure that the power supply matches the product specification voltage Do not attempt to operate a 120V specification product on 230V power or...

Page 10: ...nctions as a stand alone device Dipswitch 10 must always be set to OFF for custom control You can set dipswitch 1 2 3 4 5 7 8 or 9 to your desired operating mode Single LED move from left to right and...

Page 11: ...ve control 1 Fasten the effect light onto firm trussing Leave at least 0 5 meter on all sides for air circulation 2 Use a 3 p XLR cable to connect the Quadro Flower The pins 1 Earth 2 Signal 3 Signal...

Page 12: ...proper electric power supply sockets starting with the first unit Do not supply power before the whole system is set up and connected properly Multiple Quadro Flowers DMX Max 30 Quadro Flowers Fig 4 N...

Page 13: ...41 Explanation Since each unit has 10 channels each address advances 10 values See Address Value above Once address values are determined add DMX dip switch values to obtain the appropriate address DM...

Page 14: ...12...

Page 15: ...er may result in deterioration of the digital DMX signal Maximum recommended DMX data link distance 100 meters Maximum recommended number of Quadro Flowers on a DMX data link 30 fixtures Data Cabling...

Page 16: ...vement 2 Only works when CH1 is set between 50 99 0 255 Left to right from slow to fast Channel 6 LED movement 3 Only works when CH1 is set between 50 99 0 255 Inside to outside from slow to fast Chan...

Page 17: ...d fuse If brown or unclear it is burned out 4 Insert the replacement fuse into the holder where the old fuse was Reinsert the fuse cover Be sure to use a fuse of the same type and specification See th...

Page 18: ...uilt in programs Auto run Static Color DMX Sound active Master Slave Recall last operation when power is on again Auto running loops selectable Music controlled via built in microphone Fuse 2A 250V Di...

Page 19: ......