Basic Cleaning Instructions
The external lens of the device must be cleaned periodically in order to optimize the light output. The
cleaning schedule depends on the conditions at the site where the device is installed. When smoke or
fog machines are used at the site, the device will need more frequent cleaning. On the other hand, if the
device is installed in well-ventilated area, it will need less frequent cleaning. To establish a cleaning
schedule, examine the device at regular intervals during the first 100 hours of operation.
To clean the device, follow the steps below:
Disconnect the device from the electrical power supply.
Allow the device to cool down for at least 15 minutes.
Remove the dust collected on the external surface with dry compressed air and a soft brush.
Clean the lens with a damp cloth. Use a mild detergent solution.
Dry the lens carefully with a lint-free cloth.
Clean the DMX and other connections with a damp cloth.
Attention
●
Do not immerse the device in liquid.
●
Do not use alcohol or solvents.
●
Make sure that the connections are fully dry before connecting the device to the power supply and
to other devices.
Corrective Maintenance
The device does not contain user-serviceable parts. Do not open the device and do not modify the
device.
Refer repairs and servicing to instructed or skilled persons. Contact your Highlite International dealer for
more information.
Replacing the Fuse
DANGER
Electric shock caused by short-circuit
●
Do not bypass the thermostatic switch or fuses.
●
For replacement use fuses of the same type and rating only.
Power surges, short-circuit or incorrect electrical power supply may cause a fuse to burn out. If the fuse
burns out, the device will not function anymore. If this happens, follow the steps below.
01)
Disconnect the device from the electrical power supply.
02)
Allow the device to cool down for at least 15 minutes.
03)
Loosen the fuse cover with a screwdriver and remove the fuse holder.
04)
If the fuse is brown or unclear, it is burned out. Remove the old fuse.
05)
Insert a new fuse in the fuse holder. Make sure that the type and the rating of the replacement fuse
are the same as the ones specified on the information label of the product.
06)
Replace the fuse holder in the opening and tighten the fuse cover.
Summary of Contents for Performer 1500 Fresnel Daylight
Page 24: ...23 Performer 1500 Fresnel Daylight Product code 33132 Menu Overview...
Page 25: ...24 Performer 1500 Fresnel Daylight Product code 33132...
Page 38: ...37 Performer 1500 Fresnel Daylight Product code 33132...
Page 39: ...38 Performer 1500 Fresnel Daylight Product code 33132...
Page 40: ...2020 Showtec...