background image

 

15 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Problem 

Probable cause(s) 

Remedy 

 
One or more 
fixtures are 
completely dead. 

No power to the fixture 

• Check that power is switched on 

and cables are plugged in. 

Primary fuse blown. 

• Replace fuse. 
 

Fixtures reset 
correctly, but all 
respond 
erratically or not 
at all to the 
controller. 

The controller is not connected. 

• Connect controller.  

3-pin XLR Out of the controller 
does not match XLR Out of the first 
fixture on the link (i.e. signal is 
reversed). 

• Install a phase reversing cable 

between the controller and the first 
fixture on the link. 

 
 
 
 
 
 
 
 
 
 
Fixtures reset 
correctly, but 
some respond 
erratically or not 
at all to the 
controller. 

 
 
 
Poor data quality 

• Check data quality. If much lower 

than 100 percent, the problem may 
be a bad data link connection, poor 
quality or broken cables, missing 
termination plug, or a defective 
fixture disturbing the link. 

 
Bad data link connection 

• Inspect connections and cables. 

Correct poor connections. Repair or 
replace damaged cables.  

Data link not terminated with 120 
Ohm termination plug. 

• Insert termination plug in output jack 

of the last fixture on the link. 

Incorrect addressing of the fixtures.  • Check address setting.  
 

 

One of the fixtures is defective and 
disturbs data transmission on the 
link. 

• Bypass one fixture at a time until 

normal operation is regained: unplug 
both connectors and connect them 
directly together. 

• Have the defective fixture serviced 

by a qualified technician.  

 
3-pin XLR Out on the fixtures does 
not match (pins 2 and 3 reversed). 

• Install a phase-reversing cable 

between the fixtures or swap pin 2 
and 3 in the fixture, that behaves 
erratically.  

Shutter closes 
suddenly 

The color wheel has lost its index 
position and the fixture is resetting 
the effect. 

• Contact a technician for servicing 

the problem persists. 

 

 

 
No light 

Fixture is too hot. 

• Allow fixture to cool. 
• Clean fan. 
• Make sure air vents at control panel 

and front lens are not blocked. 

•  Turn up the air conditioning . 

 

LEDs damaged 

• Disconnect fixture and return to your 

dealer. 

The power supply settings do not 
match local AC voltage and 
frequency. 

• Disconnect fixture. Check settings 

and correct if necessary. 

 

Summary of Contents for led par 56 short pro rgb

Page 1: ...LED PAR 56 Short Pro RGB ORDERCODE 42426 Highlite International B V Vestastraat 2 6468 EX Kerkrade The Netherlands Phone 31 45 5667700...

Page 2: ...ly on Showtec for more excellent lighting products We design and manufacture professional light equipment for the entertainment industry New products are being launched regularly We work hard to keep...

Page 3: ...One LED Par 56 Short Pro Auto Run Mode 7 One LED Par 56 Short Pro Sound control 7 Multiple LED Pars Master Slave control 8 Multiple LED Pars DMX Control 8 Fixture Linking 9 Data Cabling 9 Control Pan...

Page 4: ...ble lifespan of 40 000 to 50 000 hours will be achieved under normal operational conditions If improving on this lifespan expectancy is of a higher priority place care in providing for lower operation...

Page 5: ...t higher than stated on the rear panel Make sure that the power cord is never crimped or damaged Check the device and the power cord from time to time Make sure that no side forces can impact on the t...

Page 6: ...t the installation yourself Always let the installation be carried out by an authorized dealer Procedure If the LED Par 56 Short Pro is lowered from the ceiling or high joists professional trussing sy...

Page 7: ...od to use Note If you are given an RMA number please include the following information on a piece of paper inside the box 1 Your name 2 Your address 3 Your phone number 4 A brief description of the sy...

Page 8: ...ue Beam angle 20 degrees Control DMX Auto Music Master Slave DMX 512 Addressing Digital addressing DMX Mode 3 and 6 channel mode DMX Connector 3 pole XLR DMX IN and DMX OUT Filterframe Included Fuse T...

Page 9: ...and you have pressed enter then the fixture is manually controlled Please see page 12 for more information about the Color Jump Mode One LED Par 56 Short Pro Color Dream Mode 1 Fasten the effect light...

Page 10: ...e second unit s in socket Repeat this process to link the second third and fourth units You can use the same functions on the master device as described on page 12 This means on the master device you...

Page 11: ...portant Fixtures on a serial data link must be daisy chained in one single line To comply with the EIA 485 standard no more than 30 devices should be connected on one data link Connecting more than 30...

Page 12: ...rt Pro should be 1 6 7 007 the DMX address of the third LED Par 56 Short Pro should be 7 6 13 013 etc Please be sure that you don t have any overlapping channels in order to control each LED Par 56 Sh...

Page 13: ...able and the DMX controller must be turned on The LED Par 56 Short Pro system can operate as a 3 or 6 channel DMX fixture 1 DMX Mode 1 Press the MODE button on the device until the display shows 2 You...

Page 14: ...enus you can set the Color Dream Mode of the LED Par 56 Short Pro Use the Up Down buttons to adjust the Color Jump Speed from 5 Auto Run Program 1 Press the MODE button on the device until the display...

Page 15: ...t sensitive to most sensitive Channel 6 Built in Programs 0 31 No Function 32 63 Slow Fade In to Full beam then Out 64 95 Full beam to slow Fade Out 96 127 Slow Fade In to Full Beam to Slow Fade Out 1...

Page 16: ...t a flat head screwdriver into a slot in the fuse cover Turn the screwdriver to the left at the same time gently push a bit Turn and Push The fuse will come out 3 Remove the used fuse If brown or uncl...

Page 17: ...es Data link not terminated with 120 Ohm termination plug Insert termination plug in output jack of the last fixture on the link Incorrect addressing of the fixtures Check address setting One of the f...

Page 18: ...Control DMX Auto Music Master Slave DMX 512 Addressing Digital addressing DMX Mode 3 and 6 channel mode DMX Connector 3 pole XLR DMX IN and DMX OUT Filterframe Included Fuse T 0 5A 250V Dimensions 260...

Page 19: ......