Illumilift RGBW Turbo             V1 

Highlite International B.V. – Vestastraat 2 – 6468 EX – Kerkrade – the Netherlands 

Order code: 41166 

MANUAL 

ENGLISH 

Summary of Contents for Illumilift RGBW Turbo

Page 1: ...Illumilift RGBW Turbo V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Order code 41166 MANUAL ENGLISH...

Page 2: ...tup and Operation 9 Control Modes 10 One Illumilift Manual 10 Multiple Illumilifts DMX Control 10 Fixture Linking 11 Data Cabling 11 Control Panel 12 Control Mode 12 DMX Addressing 12 Menu Overview 13...

Page 3: ...ts to ensure that all parts are present and have been received in good condition Notify the dealer immediately and retain packing material for inspection if any parts appear damaged from shipping or t...

Page 4: ...EDs Never look directly into the light source Never leave any cables lying around Never use the device during thunderstorms unplug the device immediately Never leave various parts of the packaging pla...

Page 5: ...ly in the original packing material and return it to your Showtec dealer for service For adult use only The device must be installed beyond the reach of children Never leave the unit running unattende...

Page 6: ...inging freely in the room The installation must always be secured with a safety attachment e g an appropriate safety net or a safety cable that can hold a minimum point load of 10 times the device s l...

Page 7: ...roper UPS packing or double boxing is always a safe method to use Note If you are given an RMA number please include the following information on a piece of paper inside the box 01 Your name 02 Your a...

Page 8: ...nnel Refresh rate 19 6 kHz Dimmer 0 100 Strobe 0 20 Hz DMX control via standard DMX controller DMX channels 6 10 channels Control Manual DMX 512 Housing Metal flame retardant plastic Cooling Cooling f...

Page 9: ...DMX signal connector OUT 05 3 pin DMX signal connector IN 06 Power switch ON OFF 07 100 240 V pro power connector IN Blue 08 100 240 V pro power connector OUT Gray 09 Ground earth connection 10 Fuse...

Page 10: ...rtical position and or the LED sphere is not installed it may result in twisting of the cable that may cause damage to the built in winch system and the warranty will become void Before powering the I...

Page 11: ...ht to a firm trussing Leave at least 0 5 meter on all sides for air circulation 02 Always use a safety cable ordercode 70140 70141 03 Use a 3 pin XLR cable to connect the Illumilifts and other devices...

Page 12: ...a dealer distributor or construct your own cable If you choose to create your own cable please use data grade cables that can carry a high quality signal and are less prone to electromagnetic interfe...

Page 13: ...is not interrupted in any way Control Panel A LED display B MENU button C UP button D DOWN button E ENTER button Fig 05 Control Mode The fixtures are individually addressed on a data link and connect...

Page 14: ...the controller is not connected with the input of the Illumilift RGBW Turbo The controller is switched off or defective the cable or connector is detective or the signal wires are swapped in the inpu...

Page 15: ...n manually set the desired colors 01 In main menu press the MENU button until the display shows 02 Press the ENTER button to toggle through the following options Red LED brightness from dark to bright...

Page 16: ...05 111 Color 15 R255 G000 B100 W000 112 118 Color 16 R255 G000 B025 W000 119 125 Color 17 R000 G000 B000 W255 126 132 Color 18 R255 G255 B255 W255 133 139 Color switch 1 140 146 Color switch 2 147 153...

Page 17: ...must be open 0 255 Gradual adjustment White from dark to brightest Channel 6 Strobe CH1 must be open CH2 5 must be open 0 10 Not functional 11 255 Strobe flash frequency from OFF to highest frequency...

Page 18: ...inking equipment or supplying electric power Replacing the Fuse Power surges short circuit or inappropriate electrical power supply may cause a fuse to burn out If the fuse burns out the product will...

Page 19: ...ond erratically or not at all to the controller Poor data quality Check data quality If much lower than 100 percent the problem may be a bad data link connection poor quality or broken cables missing...

Page 20: ...oad 2 kg Lifting height 6 m Lifting speed 0 2 5 m s Lifting cable 5 x 0 5 mm2 Power on cable 4 channels max 18 V DC max 0 3A per channel Refresh rate 19 6 kHz Housing Metal flame retardant plastic DMX...

Page 21: ...20 Order code 41166 Illumilift RGBW Turbo Dimensions...

Page 22: ...21 Order code 41166 Illumilift RGBW Turbo Notes...