background image

       Fascinator

            

ORDERCODE 30918

Summary of Contents for Fascinator 30918

Page 1: ...Fascinator ORDERCODE 30918 ...

Page 2: ...n Showtec for more excellent lighting products We design and manufacture professional light equipment for the entertainment industry New products are being launched regularly We work hard to keep you our customer satisfied For more information iwant showtec info You can get some of the best quality best priced products on the market from Showtec So next time turn to Showtec for more great lighting...

Page 3: ...nd Overview Backside Installation Installing the Lamp Set Up and Operation One Fascinator Multiple Fascinators DMX Protocol Control Panel Control Mode DMX addressing Stand alone mode Functions control panel Master Slave mode Channel settings DMX Channels Maintenance Changing the Lamp Replacing the Fuse Troubleshooting No Light No Movement All Products No Response to DMX Product Specifications ...

Page 4: ...ctions with the mains with particular caution Never remove warning or informative labels from the unit Never use anything to cover the ground contact Never run the device without lamp Never look directly into the light source Never leave any cables lying around Do not insert objects into air vents Do not connect this device to a dimmerpack Do not switch the device on and off in short intervals as ...

Page 5: ...acking material and return it to your Showtec dealer for service For adult use only Lighteffect must be installed out of the reach of children Never leave the unit running unattended For replacement use lamps and fuses of same type and rating only Allow time to cool down before replacing lamp This device falls under protection class I Therefore it is essential to connect the yellow green conductor...

Page 6: ...winging freely in the room The installation must always be secured with a safety attachment e g an appropriate safety net or safety cable When rigging derigging or servicing the projector always make sure that the area below the installation place is blocked and staying in the area is forbidden Improper installation can cause serious damage to people and property Connection with the mains Connect ...

Page 7: ...r is a light effect with high output and great effects DMX control via standard DMX controller 1 DMX control channel required Sound controlled via built in microphone 2x Lamp G6 35 120V 300W Fuse T5A 250V Overview 1 2 Fig 1 1 Mounting bracket 2 Fixation screw ...

Page 8: ...6 Backside 3 4 5 6 7 8 9 Fig 2 3 Eye for safety cable 4 DMX signal connector OUT 5 DMX signal connector IN 6 Microphone 7 Audio Sensitivity 8 Ground 9 IEC power connector Fuse 5A 250V ...

Page 9: ...Do not touch the lamp bulb glass Oil on hands shortens the lamp life If you touch the bulb glass wipe off the glass with a clean lint free towel and rubbing alcohol 3 Insert the lamp pins into the small holes in the lamp socket and attach the small lamp clamp over the lamp Do the same for the second lamp 4 Close the cover back and fasten the screw snugly 1 2 3 Fig 3 Set Up and Operation Follow the...

Page 10: ...it s IEC socket then plug the other end of the mains power cord into proper electric power supply sockets starting with the first unit Do not supply power before the whole system is set up and connected properly 5 Press until the display shows F6 n or F6 y with actually stored address 6 Select the display shows Select the display shows Then select F4 y audio controlled on the master device Only on...

Page 11: ...irst Fascinator should be 1 A001 the DMX address of the second Fascinator should be 1 1 2 A002 the DMX address of the third Fascinator should be 2 1 3 A003 etc Please be sure that you don t have any overlapping channels in order to control each Fascinator correctly If two or more Fascinators are addressed similarly they will work similarly For address settings please refer to the instructions unde...

Page 12: ...e master is switched on and connected to the master slave chain Note Disconnect the fixtures from the DMX controller before master slave operating otherwise data collisions can occur and the fixtures will not work properly It s necessary to insert the XLR termination plug with 120 Ohm into the input of the master fixture and into the output of the last slave fixture in the data link in order to en...

Page 13: ... shows or with actually stored address 2 If the display shows message with actually stores address Select the display shows Select the display shows with actually stored address If you want to address no master or slave don t select 3 Only one fixture can be the master When operating the Fascinator you can identify the master fixture from the slave fixture easily The master device has no cable to ...

Page 14: ...play shows Press to music trigger The display shows with actually stored address If you want address no music trigger don t select Playing program This function allows you to run a built in program Press until the display shows or If the display shows with actually stored address Press the display shows Press to play the program the display shows with actually stored address If you want address no...

Page 15: ... fluid tends to build up residues reducing the light output very quickly The cooling fan should be cleaned monthly with a soft brush Dust will cause the fan to stop and the device will become damaged due to overheating Then the warranty will become void Please clean internal components once a year with a light brush and vacuum cleaner Keep connections clean Disconnect electric power and then wipe ...

Page 16: ...an appropriate power supply 2 The lamps Replace the old lamp with a new one with the same specifications See page 7 for replacing lamps 3 The fuse Replace the fuse See page 13 for replacing the fuse No Response to DMX Response Suspect the DMX cable or connectors a controller malfunction a light effect DMX card malfunction 1 Check the DMX cable Unplug the unit change the DMX cable then reconnect to...

Page 17: ... pin XLR female DMX control via standard DMX controller Sound controlled via built in microphone Lamp Allowed lamp models Showtec G6 35 120V 300W 50 hr ordercode 82310 Osram G6 35 120V 300W 75 hr 7700Lumen ordercode 80508 Minimum distance Minimum distance from flammable surfaces 0 5m Minimum distance to lighted object 0 8m Versions for other lamps may be produced Please check the specification lab...

Page 18: ...2005 Showtec ...

Reviews: