background image

 

  

 

 

   

 

Ordercode: 43165 

Energetic 

 

Avoid flames and do not put close to flammable liquids or gases. 

 

Always keep the case closed while operating. 

 

Always allow a free air space of at least 50 cm around the unit for ventilation. 

 

Always disconnect power from the mains, when device is not used or before cleaning! Only handle 
the power cord holding it by the plug. Never pull out the plug by tugging the power cord. 

 

Make sure that the device is not exposed to extreme heat, moisture or dust. 

 

Make sure that the available voltage is not higher than stated on the rear panel. 

 

Make sure that the power cord is never crimped or damaged. Check the device and the power 
cord from time to time. 

 

Make sure that the core diameter of extension cords and power cords is sufficient for the required 
power consumption of the device. 

 

If the external cable is damaged, it has to be replaced by a qualified technician. 

 

If the lens or LEDs are obviously damaged, it has to be replaced to prevent its functions from being 
impaired, due to cracks or deep scratches. 

 

If device was dropped or struck, disconnect mains power supply immediately. Have a qualified 
engineer inspect for safety before operating. 

 

If the device has been exposed to drastic temperature fluctuation (e.g. after transportation), do not 
switch it on immediately. The arising condensation water might damage your device. Leave the 
device switched off until it has reached room temperature. 

 

If your Showtec device fails to work properly, discontinue the use immediately. Pack the unit securely 
(preferably in the original packing material), and return it to your Showtec dealer for service. 

 

For adult use only. The device must be installed beyond the reach of children. Never leave the unit 
running unattended. 

 

Never attempt to bypass the thermostatic switch or fuses. 

 

For replacement use fuses of same type and rating only. 

 

The operation of a class 3R laser show laser is only allowed if the show is controlled by a skilled and 
well-trained operator familiar with the data included in this manual. 

 

The user is responsible for correct positioning and operating of the device. The manufacturer will not 
accept liability for damages caused by the misuse or incorrect installation of this device. 

 

This device falls under protection class I. Therefore it is essential to connect the yellow/green 
conductor to earth. 

 

The laser will only work between 10-35ºC. 

 

After 3 hours working, you must shut off the laser and let the laser diode cool off for 30 minutes, 
otherwise the laser could be damaged and the warranty becomes void. 

 

Repairs, servicing and electric connection must be carried out by a qualified technician. 

 

WARRANTY: Till one year after date of purchase. 

 
 

 

 

 

 

           

 

Summary of Contents for Energetic V1

Page 1: ...Energetic V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 43165 MANUAL ENGLISH...

Page 2: ...Sound controlled 12 Multiple Energetics Master Slave control 13 Multiple Energetics DMX Control 14 Fixture Linking 15 Data Cabling 15 Control Panel 16 Control Mode 16 DMX Addressing 16 Menu Overview 1...

Page 3: ...power cable 1 5 m 2 keys for the interlock Remote control plug IR remote control User manual LED Expected Lifespan LEDs gradually decline in brightness over time HEAT is the dominant factor that lead...

Page 4: ...point a laser at aircraft this is a federal offense Never point unterminated laser beams into the sky Never open the laser housing The high laser power levels inside of the protective housing can sta...

Page 5: ...after transportation do not switch it on immediately The arising condensation water might damage your device Leave the device switched off until it has reached room temperature If your Showtec device...

Page 6: ...r your audience Even very small amounts of laser light are potentially hazardous even at long distances Laser eye injuries can happen quicker than you can blink It is incorrect to think that because t...

Page 7: ...agencies military and others require all lasers to be used under the guidelines of ANSI Z136 1 Laser Display guidance can be obtained via the International Laser Display Association www ilda com inde...

Page 8: ...net or safety cable When rigging derigging or servicing the Energetic always make sure that the area below the installation site is secured and that there are not any unauthorized people around The E...

Page 9: ...number 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this c...

Page 10: ...IP20 Housing Die cast black aluminum Cooling Cooling fan Connections IEC connectors IN OUT 3 pin XLR IN OUT Fuse T1L 250V Dimensions 260 x 190 x 188 mm LxWxH Weight 1 8 kg LED effect Light source 1 x...

Page 11: ...stment screw Backside Fig 03 07 Sound sensitivity control 08 Safety eye 09 Ground earth connection 10 IEC power connector OUT 11 IEC power connector IN Fuse T1L 250V 12 3 pin DMX signal connector OUT...

Page 12: ...roduct specification voltage Do not attempt to operate a 120V specification product on 230V power or vice versa Connect the device to the main power supply The device can be sound controlled as it is...

Page 13: ...air circulation 02 Always use a safety cable ordercode 70140 70141 03 Plug the end of the electric mains power cord into a proper electric power supply socket 04 When the Energetic is not connected w...

Page 14: ...he units as shown in Fig 06 connect a DMX signal cable from the first unit s DMX out socket to the second unit s in socket Repeat this process to link the second and third units You can use the same f...

Page 15: ...nnect the first unit s DMX out socket with the second unit s in socket using a DMX signal cable Repeat this process to link the second and third units 05 Supply electric power Plug electric mains powe...

Page 16: ...obtain data cables You can purchase DAP Audio certified DMX cables directly from a dealer distributor or construct your own cable If you choose to create your own cable please use data grade cables th...

Page 17: ...getic should be 1 001 the DMX address of the second Energetic should be 1 9 10 010 the DMX address of the third Energetic should be 10 9 19 019 etc Please be sure that you do not have any overlapping...

Page 18: ...etic Menu Overview The Energetic will only show its version number at start up Main Menu Options 2 channel mode 9 channel mode Static colors Built in programs Program speed Sound controlled Manual IR...

Page 19: ...ce 4 Built in Programs With this menu you can set the built in programs 01 Press the MODE button until the display shows 02 Press the ENTER button to open the menu 03 Press the UP DOWN buttons to choo...

Page 20: ...adual adjustment blue intensity 0 255 Gradual adjustment white intensity 0 255 Strobe speed from slow to fast 04 Press the UP DOWN buttons to change the values 05 Press the ENTER button to save change...

Page 21: ...he device receives a sound signal the Music LED indicator at the backside will blink Green LED LED auto mode Press the button to activate deactivate the LED program Strobe auto mode Repeatedly press t...

Page 22: ...4 LEDs laser strobe 45 79 LEDs strobe 80 114 LEDs laser 115 149 Laser strobe 150 184 LEDs 185 219 Strobe 220 255 Laser Channel 2 Built in Program Speed Programs CH1 must be set between 10 255 0 250 Gr...

Page 23: ...1 from slow to fast 120 129 Pattern 12 from slow to fast 130 139 Pattern 13 from slow to fast 140 149 Pattern 14 from slow to fast 150 159 Pattern 15 from slow to fast 160 169 Pattern 16 from slow to...

Page 24: ...echnical installations are to be inspected by a skilled person once a year The following points have to be considered during the inspection 01 All screws used for installing the device or parts of the...

Page 25: ...the DMX cable then reconnect to electrical power Try your DMX control again 03 Determine whether the controller or light effect is at fault Does the controller operate properly with other DMX product...

Page 26: ...ot terminated with 120 Ohm termination plug Insert termination plug in output jack of the last fixture on the link Incorrect addressing of the fixtures Check address setting One of the fixtures is def...

Page 27: ...er 130mW 100mW 650nm Red 30mW 532nm Green Laser Class 3R Safety Features Key switch Interlock Safety eye Laser Safety EN IEC 60825 1 Ed 2 2007 03 Strobe effect 16 x 0 5W White 5730 LEDs Housing Die ca...

Page 28: ...27 Ordercode 43165 Energetic Dimensions...

Page 29: ...28 Ordercode 43165 Energetic Notes...

Page 30: ...29 Ordercode 43165 Energetic...

Page 31: ...30 Ordercode 43165 Energetic...

Page 32: ...2018 Showtec...

Reviews: