background image

 

  

 

 

   

 

Ordercode: 42599 

Compact Par 7/15 Q4  

Before the initial start-up, please make sure that there is no damage caused by transportation.  
Should there be any, consult your dealer and do not use the device. 
 
To maintain perfect condition and to ensure a safe operation, it is absolutely necessary for the user to 
follow the safety instructions and warning notes contained in this manual. 
 
Please consider that damages caused by manual modifications to the device are not subject to 
warranty. 
 
This device contains no user-serviceable parts. Refer servicing to qualified technicians only. 
 

IMPORTANT: 

The manufacturer will not accept liability for any resulting damages caused by the non-observance of 
this manual or any unauthorized modification to the device. 
 

 

Never let the power cord come into contact with other cables! Handle the power cord and all 
connections with the mains with particular caution! 

 

Never remove warning or informative labels from the unit. 

 

Never use anything to cover the ground contact. 

 

Never lift the fixture holding it by the projector-head, as the mechanics may be damaged. Always 
hold the fixture by the transport handles. 

 

Never place any material over the lens. 

 

Never look directly into the light source. 

 

Never leave any cables lying around. 

 

Never loosen the screws of the rotating gobo otherwise you risk opening of the ball bearing. 

 

Do not insert objects into air vents. 

 

Do not connect this device to a dimmerpack. 

 

Do not switch the device on and off in short intervals, as this will reduce the device’s life. 

 

Do not touch the device’s housing bare-handed during its operation (housing becomes very hot). 
Allow the fixture to cool for at least 5 minutes before handling. 

 

Do not shake the device. Avoid brute force when installing or operating the device. 

 

Only use the device indoors, avoid contact with water or other liquids. 

 

Only operate the fixture after having checked if the housing is firmly closed and all screws are tightly 
fastened. 

 

Only operate the device after having familiarized with its functions. 

 

Avoid flames and do not put close to flammable liquids or gases. 

 

Always keep the case closed while operating. 

 

Always allow a free air space of at least 50 cm around the unit for ventilation. 

 

Always disconnect power from the mains, when device is not used or before cleaning! Only handle 
the power cord holding it by the plug. Never pull out the plug by tugging the power cord. 

 

Make sure that the device is not exposed to extreme heat, moisture or dust. 

 

Make sure that the available voltage is not higher than stated on the rear panel. 

 

Make sure that the power cord is never crimped or damaged. Check the device and the power 
cord from time to time. 

 

If the lens is obviously damaged, it has to be replaced. 

 

If device was dropped or struck, disconnect mains power supply immediately. Have a qualified 
engineer inspect for safety before operating. 

 

If the device has been exposed to drastic temperature fluctuation (e.g. after transportation), do not 
switch it on immediately. The arising condensation water might damage your device. Leave the 
device switched off until it has reached room temperature. 

 

If your Showtec device fails to work properly, discontinue the use immediately. Pack the unit securely 
(preferably in the original packing material), and return it to your Showtec dealer for service. 

 

For adult use only. The fixture must be installed beyond the reach of children. Never leave the unit 
running unattended. 

 

Never attempt to bypass the thermostatic switch or fuses. 

 

For replacement use fuses of same type and rating only. 

 

 

Summary of Contents for Compact Par 7/15 Q4

Page 1: ...Compact Par 7 15 Q4 V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 42599 MANUAL ENGLISH...

Page 2: ...ltiple Compact Pars Master Slave control 9 Multiple Compact Pars DMX Control 10 Fixture Linking 11 Data Cabling 11 Control Panel 12 Control Mode 12 DMX Addressing 12 Menu Overview 13 Main Menu Options...

Page 3: ...mpact Par 7 15 Q4 ProPower cable 1 4 m Accessory holder incl screws Filter frame User manual LED Expected Lifespan LEDs gradually decline in brightness over time HEAT is the dominant factor that leads...

Page 4: ...efore handling Do not shake the device Avoid brute force when installing or operating the device Only use the device indoors avoid contact with water or other liquids Only operate the fixture after ha...

Page 5: ...never be exceeded The relative humidity must not exceed 50 with an ambient temperature of 40 C If this device is operated in any other way than the one described in this manual the product may suffer...

Page 6: ...with the mains Connect the device to the mains with the power plug Always check if the right color cable is connected to the right place International EU Cable UK Cable US Cable Pin L BROWN RED YELLO...

Page 7: ...number 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this c...

Page 8: ...or easy setup Light source 7 x 15W RGBW LEDs Output 2m 8950lux Control modes Auto Sound controlled Static color Master Slave DMX Control protocol DMX 512 Dimmer 0 100 Strobe 0 5 10Hz Beam Angle 15 Pro...

Page 9: ...foam and plastic padding is removed Connect all cables Do not supply power before the whole system is set up and connected properly Always disconnect from electric mains power supply before cleaning...

Page 10: ...electric mains power cord into a proper electric power supply socket 04 Turn on the music If the device is set to sound control then the Compact Par will react to the beat of the music Please see pag...

Page 11: ...nnect the first unit s DMX out socket with the second unit s in socket using a DMX signal cable Repeat this process to link the second third and fourth units 05 Supply electric power Plug electric mai...

Page 12: ...obtain data cables You can purchase DAP Audio certified DMX cables directly from a dealer distributor or construct your own cable If you choose to create your own cable please use data grade cables th...

Page 13: ...uld be 11 10 21 021 etc Please be sure that you do not have any overlapping channels in order to control each Compact Par correctly If two or more Compact Pars are addressed similarly they will work s...

Page 14: ...13 Ordercode 42599 Compact Par 7 15 Q4 Menu Overview The Compact Par will show the following screens at start up First screen Second screen last operation mode...

Page 15: ...wn buttons to choose between 5 types of built in programs 04 Choose the desired built in program 05 Press the Enter button again to adjust the speed of the built in program 06 Press the Up and Down bu...

Page 16: ...u the display shows 03 Press the Enter button again to enter the submenu 04 Press the Up and Down buttons to adjust the sensitivity 05 The adjustment range is between 06 Turn on the music and the Comp...

Page 17: ...r button to open the menu 03 Press the Up and Down buttons to set the desired DMX address 04 The adjustment range is between 8 DMX configuration With this menu you can set the desired DMX configuratio...

Page 18: ...Dimmer intensity 0 255 Gradual adjustment Blue from 0 100 Channel 4 White Dimmer intensity 0 255 Gradual adjustment White from 0 100 6 channels Channel 1 Red Dimmer intensity CH5 must be set between 1...

Page 19: ...intensity CH1 must be set between 1 255 0 255 Gradual adjustment White from 0 100 Channel 6 RGBW Fade CH1 must be set between 1 255 0 255 Gradual adjustment from Red to RGBW Channel 7 Strobe CH1 and...

Page 20: ...llow the directions below 01 Unplug the unit from electric power source 02 Insert a flat headed screwdriver into a slot in the fuse cover Turn the screwdriver to the left at the same time gently push...

Page 21: ...ctions and cables Correct poor connections Repair or replace damaged cables Data link not terminated with 120 Ohm termination plug Insert termination plug in output jack of the last fixture on the lin...

Page 22: ...t 3 pin 5 pin DMX OUT Electro mechanical effects LED Quantity 7 x 15W RGBW LED Output 2m 8950lux Color mixing RGBW Beam angle 15 Dimmer 0 100 Strobe 0 5 10Hz Housing Die cast black aluminum DMX contro...

Page 23: ...22 Ordercode 42599 Compact Par 7 15 Q4 Dimensions...

Page 24: ...2017 Showtec...