Operating Determinations 

 

This device is not designed for permanent operation. Consistent operation breaks will ensure that the 
device will serve you for a long time without defects. 

 

The minimum distance between light-output and the illuminated surface must be more than 0,5 meter. 

 

The maximum ambient temperature 

t

a

 = 45°C must never be exceeded. 

 

The relative humidity must not exceed 50 % with an ambient temperature of 45° C. 

 

If this device is operated in any other way, than the one described in this manual, the product may 
suffer damages and the

 

warranty becomes void. 

 

Any other operation may lead to dangers like short-circuit, burns, electric shock, crash etc. 

 

 

You endanger your own safety and the safety of others! 

 

Improper installation can cause serious damage to people and property ! 

 

 

Rigging

 

Please follow the European and national guidelines concerning rigging, trussing and all other 
safety issues. 
Do not attempt the installation yourself ! 
Always let the installation be carried out by an authorized dealer !

 

 

Procedure: 

 

If the Aircone LED 1W is lowered from the ceiling or high joists, professional trussing systems have to 
be used. 

 

Use a clamp to mount the Aircone LED 1W, with the mounting-brackets, to the trussing system. 

 

The Aircone LED 1W must never be fixed swinging freely in the room.  

 

The installation must always be secured with a safety attachment, e.g. an appropriate safety net 
or safety-cable. 

 

When rigging, derigging or servicing the Aircone LED 1W, always make sure, that the area below 
the installation place is blocked and staying in the area is forbidden.  

 

The LED Aircone can be placed on a flat stage floor or mounted to any kind of truss by a clamp. 

 

Improper installation can cause serious damage to people and property ! 

 

Summary of Contents for Aircone 1W LED

Page 1: ...Aircone LED 1W ORDERCODE 40313 Highlite International B V Vestastraat 2 6468 EX Kerkrade The Netherlands Phone 31 45 5667700...

Page 2: ...on Showtec for more excellent lighting products We design and manufacture professional light equipment for the entertainment industry New products are being launched regularly We work hard to keep yo...

Page 3: ...1W Built in Programs Auto Run 8 One Aircone LED 1W Sound control 8 Multiple Aircone LED 1Ws DMX Control 8 Fixture Linking 10 Data Cabling 10 Control Panel 11 DMX Control Mode 11 DMX Addressing 11 Men...

Page 4: ...tional conditions If improving on this lifespan expectancy is of a higher priority place care in providing for lower operational temperatures This may include climatic environmental and the reduction...

Page 5: ...tated on the rear panel Make sure that the power cord is never crimped or damaged Check the device and the power cord from time to time Make sure that no side forces can impact on the truss system If...

Page 6: ...eople and property Rigging Please follow the European and national guidelines concerning rigging trussing and all other safety issues Do not attempt the installation yourself Always let the installati...

Page 7: ...od to use Note If you are given an RMA number please include the following information on a piece of paper inside the box 1 Your name 2 Your address 3 Your phone number 4 A brief description of the sy...

Page 8: ...gain 36 LEDs 12 Red 12 Green 12 Blue 7 DMX channels Straight cone and pyramid cone are included Cones are interchangeable with 40312 LED Aircone DMX cones Overview Fig 1 Fig 1 1 LED module 6 3 pin DMX...

Page 9: ...set to or then the fixture is manually controlled Please see page 14 for more information about manual control Mode One Aircone LED 1W Built in Programs Auto Run 1 Fasten the effect light onto firm t...

Page 10: ...into a proper electric power supply starting with the first unit Do not supply power before the whole system is set up and powered properly Multiple Aircone LED 1Ws Pro Set Up Max 30 Aircone LED 1Ws F...

Page 11: ...the digital DMX signal Maximum recommended DMX data link distance 100 meters Maximum recommended number of Aircone LED 1Ws on a DMX data link 30 fixtures Data Cabling To link fixtures together you mus...

Page 12: ...set the DMX addresses right So if you re in DMX mode 4 the DMX address of the first Aircone LED 1W should be 1 001 the DMX address of the second Aircone LED 1W should be 1 7 8 the DMX address of the...

Page 13: ...12 Menu Overview...

Page 14: ...LED 1W will automatically detect the presence of a DMX signal If a DMX signal is present the DMX LED will blink and the small red strip in the LCD display will light up In order to receive a DMX signa...

Page 15: ...set the Auto Mode of the Aircone LED 1W 3 There are 2 different built in programs Color flow effect from fast to slow Color switch effect from fast to slow Up F Down G buttons to change the speed of t...

Page 16: ...Macro 11 203 209 Macro 12 210 230 Macro 13 231 238 Macro 14 239 255 Macro 15 2 Channels Channel 1 0 13 Off 14 34 Macro 1 35 41 Macro 2 42 62 Macro 3 63 90 Macro 4 91 118 Macro 5 119 125 Macro 6 126 1...

Page 17: ...lows you to adjust the fade in time If channel 6 is set between 72 and 107 channel 2 allows you to adjust the fade out time If channel 6 is set between 108 and 143 channel 2 allows you to adjust the f...

Page 18: ...in Programs 0 15 Adjust colors 36 71 Slow fade in to full beam then out 72 107 Full beam to slow fade out 108 143 Slow fade in to full beam to slow fade out 144 179 Color mix 180 251 Color step 252 25...

Page 19: ...2 Insert a flat head screwdriver into a slot in the fuse cover Turn the screwdriver to the left at the same time gently push a bit Turn and Push The fuse will come out 3 Remove the used fuse If brown...

Page 20: ...n Inspect connections and cables Correct poor connections Repair or replace damaged cables Data link not terminated with 120 Ohm termination plug Insert termination plug in output jack of the last fix...

Page 21: ...40312 LED Aircone DMX cones Voltage 230V 50Hz CE Power 132W Weight 10 kg Minimum distance Minimum distance from flammable surfaces 0 5m Minimum distance to lighted object 1 3m Note You can only use th...

Page 22: ......

Reviews: