43
QubiQ S1500
Product code: 61061
Basic Cleaning Instructions
The device must be cleaned periodically from the built-up dust and fog fluid residues.
To clean the device, follow the steps below:
Disconnect the device from the electrical power supply.
Allow the device to cool down for at least 1 hour.
Remove the dust collected on the external surface with dry compressed air and a soft brush.
Clean the fog fluid residues from the fog output nozzle (06) with a damp cloth. Use only a clean, lint-
free soft cloth.
Clean the DMX and other connections with a damp cloth.
Attention
●
Do not immerse the device in liquid.
●
Do not use alcohol or solvents.
●
Make sure that the connections are fully dry before connecting the device to the power supply and
to other devices.
Cleaning the Fluid Pipes
The device must be cleaned periodically from the fog fluid residues. After every 40 hours of continuous
operation, it is recommended to run a cleaning solution composed of 80 % distilled water and 20 % white
vinegar through the system.
To clean the device, follow the steps below:
Disconnect the device from the electrical power supply.
Allow the device to cool down for at least 1 hour.
Clean out debris with vinegar and a pipe cleaner, making sure that the fog output nozzle (06) is free
of clogs.
Remove all fog liquid from the tank. See 6.4. Emptying the Tank after operation on page 25 for more
information.
Add a cleaning solution to tank.
Connect the power cable before supplying power to the device. See 4.5. Connecting to Power
Supply on page 17 for more information.
Make sure that you run the device until tank is empty.
Make sure that you use the device in spaces that have good airflow.
Repeat this 2-4 times.
Refill with fog liquid.