background image

 

Ordercode: 43630 

Spectral M950 SW 

The Spectral M950 SW can be operated with a controller in control mode or without the controller in  

stand-alone mode. 

 

Control Panel 

 

 

A)  OLED display 

B)  MODE button 

C)  UP button 

D)  DOWN button 

 

 

 

Fig. 05 

 

 

 

Control Mode 

The fixtures are individually addressed on a data-link and connected to the controller.  

The fixtures respond to the DMX signal from the controller. (When you select the DMX address and save it, 

the controller will display the saved DMX address, next time.) 

 

DMX Addressing 

The control panel on the front side of the base allows you to assign DMX fixture addresses, which is the first 

channel with which the Spectral will respond to the controller. 

Please note, when you use the controller, the unit has 13 channels. 

When using multiple Spectrals, make sure you set the DMX addresses right. 

Therefore, the DMX address of the first Spectral should be 1(001); the DMX address of the second 

Spectral should be 1+13=14 (014); the DMX address of the third Spectral should be 14+13=27 (027), etc. 

Please, be sure that you do not have any overlapping channels in order to control each Spectral 

correctly. If two or more Spectrals are addressed similarly, they will work similarly. 

 

Controlling: 

After having addressed all Spectral fixtures, you may now start operating these via your lighting 

controller. 

Note: After switching on, the Spectral will automatically detect whether DMX 512 data is received or not.  

If there is no data received at the DMX-input, the “LED “ on the control panel will not flash. 

If not, the problem may be: 

 

The XLR cable from the controller is not connected with the input of the Spectral M950 SW. 

 

The controller is switched off or defective, the cable or connector is detective, or the signal wires are 

swapped in the input connector. 

 

Note: It is necessary to insert an XLR termination plug (with 120 Ohm) in the last fixture in order to ensure 

proper transmission on the DMX data link.  

 

 

Display Off after 10 seconds

 

 

When no button is pressed for 10 seconds, the display will turn off. 

To light up the display, you have to press the MODE, UP or DOWN button and hold it down for 3 seconds. 

Once you have pressed the button, the display will light up. 

 

  

 

 

12 

   

 

Summary of Contents for 43630

Page 1: ...Spectral M950 SW V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 43630 MANUAL ENGLISH...

Page 2: ...Control Panel 12 Control Mode 12 DMX Addressing 12 Menu Overview 13 Main Menu Options 14 1 Power Saving Mode Full Power Mode 14 2 Display lock 15 3 DMX 3 channel mode 15 4 DMX 7 channel mode 15 5 DMX...

Page 3: ...udes Showtec Spectral M950 SW Blue White power cable 1 5 m User manual LED Expected Lifespan LEDs gradually decline in brightness over time HEAT is the dominant factor that leads to the acceleration o...

Page 4: ...force when installing or operating the device Only use the device indoors avoid contact with water or other liquids Only operate the fixture after having checked if the housing is firmly closed and a...

Page 5: ...be exceeded The relative humidity must not exceed 50 with an ambient temperature of 40 C If this device is operated in any other way than the one described in this manual the product may suffer damag...

Page 6: ...mains Connect the device to the mains with the power plug Always check if the right color cable is connected to the right place International EU Cable UK Cable US Cable Pin L BROWN RED YELLOW COPPER...

Page 7: ...er 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this check...

Page 8: ...x 8W 3 in 1 CW WW Amber LEDs Light output 35070 lumen 1 m Refresh rate 400Hz Control modes Built in programs Manual Master Slave DMX 512 Control protocol DMX 512 Dimmer 0 100 Strobe 0 20Hz Beam Angle...

Page 9: ...plastic padding is removed Connect all cables Do not supply power before the whole system is set up and connected properly Always disconnect from electric mains power supply before cleaning or servic...

Page 10: ...Manual Mode Multiple Spectrals Master Slave control 01 Fasten the effect light onto firm trussing Leave at least 0 5 meter on all sides for air circulation 02 Use a 3 pin XLR cable to connect the Spe...

Page 11: ...ct the first unit s DMX out socket with the second unit s in socket using a DMX signal cable Repeat this process to link the second third and fourth units 05 Supply electric power Plug electric mains...

Page 12: ...you must obtain data cables You can purchase DAP Audio certified DMX cables directly from a dealer distributor or construct your own cable If you choose to create your own cable please use data grade...

Page 13: ...should be 14 13 27 027 etc Please be sure that you do not have any overlapping channels in order to control each Spectral correctly If two or more Spectrals are addressed similarly they will work sim...

Page 14: ...Ordercode 43630 Spectral M950 SW Menu Overview 13...

Page 15: ...menu you can set the desired energy mode 01 Press the MODE button until the display shows or 02 When the display shows the device is operating in Power Saving Mode Its output is limited in response to...

Page 16: ...e MODE button until the display shows 02 Press the UP DOWN buttons to set the desired DMX address The adjustment range is between 1 512 6 Color temperature With this menu you can set the desired color...

Page 17: ...he MODE button until the display shows 02 Press the UP DOWN buttons to increase decrease the Amber LED brightness The adjustment range is between 0 255 from dark to brightest 03 You can combine Cool W...

Page 18: ...htest 0 100 Channel 2 Cool White Dimmer must be open 0 255 Gradual adjustment Cool White from 0 100 Channel 3 Warm White Dimmer must be open 0 255 Gradual adjustment Warm White from 0 100 Channel 4 Am...

Page 19: ...m 0 100 Channel 7 Amber Dimmer must be open and CH12 must be set between 0 35 0 255 Gradual adjustment Amber from 0 100 Channel 8 Fine Amber Dimmer must be open and CH12 must be set between 0 35 0 255...

Page 20: ...clean with glass cleaner and a soft cloth Do not use alcohol or solvents The front lens will require weekly cleaning as smoke fluid tends to build up residues reducing the light output very quickly P...

Page 21: ...y or not at all to the controller Poor data quality Check data quality If much lower than 100 percent the problem may be a bad data link connection poor quality or broken cables missing termination pl...

Page 22: ...tput 35070 lumen 1 m Color mixing CW WW A Beam angle 25 Dimmer 0 100 Strobe 0 20Hz Refresh rate 400Hz Housing Metal Flame retardant plastic DMX control via standard DMX controller On Board OLED displa...

Page 23: ...Ordercode 43630 Spectral M950 SW Dimensions 22...

Page 24: ...2015 Showtec...

Reviews: