IMPORTANT:

 

The manufacturer will not accept liability for any resulting damages caused by the non-
observance of this manual or any unauthorized modification to the device. 

 

 

Never let the power-cord come into contact with other cables! Handle the power-cord and all 
connections with the mains with particular caution! 

 

Never remove warning or informative labels from the unit. 

 

Never use anything to cover the ground contact. 

 

Never look directly into the light source. 

 

Never leave any cables lying around. 

 

Never use the device during thunderstorms, unplug the device immediately. 

 

Never leave various parts of the packaging (plastic bags, polystyrene foam, nails, etc.) within 
children’s reach, as they are potential sources of danger. 

 

Never use the device during thunderstorms, unplug the device immediately. 

 

Do not insert objects into air vents. 

 

Do not open the device and do not modify the device. 

 

Do not connect this device to a dimmerpack. 

 

Do not shake the device. Avoid brute force when installing or operating the device. 

 

Do not switch the device on and off in short intervals, as this would reduce the system’s life. 

 

Only use device indoor, avoid contact with water or other liquids. 

 

Only operate the device after having familiarized with its functions. 

 

Only install the device with the hanging-bracket. 

 

Avoid flames and do not put close to flammable liquids or gases. 

 

Always allow free air space of at least 50 cm around the unit for ventilation. 

 

Always disconnect power from the mains, when device is not used or before cleaning! Only 
handle the power-cord by the plug. Never pull out the plug by tugging the power-cord. 

 

Make sure that the device is not exposed to extreme heat, moisture or dust. 

 

Make sure that the available voltage is not higher than stated on the rear panel. 

 

Make sure that the power-cord is never crimped or damaged. Check the device and the power-
cord from time to time. 

 

Make sure that no side forces can impact on the truss system. 

 

The cable insert or the female part in the device must never be strained. There must always be 
sufficient cable to the device. Otherwise, the cable may be damaged which may lead to deadly 
electrical shocks. 

 

If the external cable is damaged, it has to be replaced by a qualified technician. 

 

If the lens is obviously damaged, it has to be replaced. So that its functions are not impaired, due 
to cracks or deep scratches. 

 

If device is dropped or struck, disconnect mains power supply immediately. Have a qualified 
engineer inspect for safety before operating. 

 

If the device has been exposed to drastic temperature fluctuation (e.g. after transportation), do 
not switch it on immediately. The arising condensation water might damage your device. Leave 
the device switched off until it has reached room temperature. 

 

If your Showtec device fails to work properly, discontinue use immediately. Pack the unit securely 
(preferably in the original packing material), and return it to your Showtec dealer for service. 

 

For adult use only. The device must be installed out of the reach of children. Never leave the unit 
running unattended. 

 

For replacement use fuses of same type and rating only. 

 

The user is responsible for correct positioning and operating of the LED Tunnel Flower. The 
manufacturer will not accept liability for damages caused by the misuse or incorrect installation 
of this device. 

 

This device falls under protection class I. Therefore it is essential to connect the yellow/green 
conductor to earth. 

 

For replacement use fuses of same type and rating only. 

 

Repairs, servicing and electric connection must be carried out by a qualified technician. 

 

WARRANTY: Till one year after date of purchase. 

 
 
 
 

Summary of Contents for 43031

Page 1: ...LED Tunnel Flower ORDERCODE 43031...

Page 2: ...on Showtec for more excellent lighting products We design and manufacture professional light equipment for the entertainment industry New products are being launched regularly We work hard to keep yo...

Page 3: ...eturn Procedure Claims Description Features and Overview Backside Installation Set Up and Operation Control Modes Built in Programs 1 7 All LEDs ON Automatic Sound Control Mode Master Slave Mode DMX M...

Page 4: ...000 hours will be achieved under normal operational conditions If improving on this lifespan expectancy is of a higher priority place care in providing for lower operational temperatures This may inc...

Page 5: ...le voltage is not higher than stated on the rear panel Make sure that the power cord is never crimped or damaged Check the device and the power cord from time to time Make sure that no side forces can...

Page 6: ...yourself Always let the installation be carried out by an authorized dealer Procedure If the LED Tunnel Flower is lowered from the ceiling or high joists professional trussing systems have to be used...

Page 7: ...description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this check after our ann...

Page 8: ...lue 126 Beam angle 15 9 DMX channels Addressing by dipswitches Operation mode DMX512 Master Slave Sound controlled Built in Programs music controlled via built in microphone Fuse F2A 250V Overview 1 F...

Page 9: ...sconnect from electric mains power supply before cleaning or servicing Damages caused by non observance are not subject to warranty Control Modes There are 4 Modes 1 Built in Programs 1 7 All LEDs ON...

Page 10: ...ter on all sides for air circulation 2 Use a 3 p XLR cable to connect the LED Tunnel Flower The pins 1 Earth 2 Signal 3 Signal 3 Link the units as shown in Fig 3 Connect a DMX signal cable from the fi...

Page 11: ...cess to link the second third and fourth units 4 Set DMX dip switches as follows See Dip Switch setting page 10 LED Tunnel Flower Address Value DMX Dip Switches ON Unit 1 1 Unit 2 10 Unit 3 19 Unit 4...

Page 12: ...Switches ON Unit 5 37 1 3 6 Switch Value 1 1 3 4 6 32 Total sum 37 Explanation Since each unit has 9 channels each address advances 9 values See Address Value above Once address values are determined...

Page 13: ...11...

Page 14: ...Function 132 255 Static Display Channel 4 Cluster 3 0 31 No Function 32 63 Mode 1 64 95 Mode 2 96 127 Mode 3 128 131 No Function 132 255 Static Display Channel 5 Cluster 4 0 31 No Function 32 63 Mode...

Page 15: ...n the course of an acceptance test The operator has to make sure that safety relating and machine technical installations are to be inspected by a skilled person once a year The following points have...

Page 16: ...orrectly but all respond erratically or not at all to the controller The controller is not connected Connect controller 3 pin XLR Out of the controller does not match XLR Out of the first fixture on t...

Page 17: ...peration mode DMX512 master slave Sound controlled auto trigger music controlled via built in microphone Fuse F26A 250V Dimensions 315 x 275 x 365 mm Weight 6 5 kg Minimum distance Minimum distance fr...

Page 18: ......

Reviews: