WARNING 

 
 
 
 
 

Unpacking Instructions 

Immediately upon receiving this product, carefully unpack the carton and check the contents to ensure 
that all parts are present, and have been received in good condition. Notify the dealer immediately and 
retain packing material for inspection if any parts appear damaged from shipping or the carton itself 
shows signs of mishandling. Save the carton and all packing materials. In the event that a fixture must be 
returned to the factory, it is important that the fixture be returned in the original factory box and packing. 

 

Your shipment includes: 

• LED Tunnel Flower with cable 1,5m and hanging-bracket. 
•User manual

 

 
 

LED Expected Lifespan 

LEDs gradually decline in brightness over time. HEAT is the dominant factor that leads to the acceleration 
of this decline. Packaged in clusters, LEDs exhibit higher operating temperatures than in ideal or singular 
optimum conditions. For this reason when all color LEDs are used at their fullest intensity, life of the LEDs is 
significantly reduced. It is estimated that a viable lifespan of 40,000 to 50,000 hours will be achieved 
under normal operational conditions. If improving on this lifespan expectancy is of a higher priority, place 
care in providing for lower operational temperatures. This may include climatic-environmental and the 
reduction of overall projection intensity. 

 

 
 
 
 

  
 

 

SAFETY INSTRUCTIONS 

Every person involved with the installation, operation and maintenance of this device has to: 

-

 

be qualified 

-

 

follow the instructions of this manual 

 
 
 
 
 
 

Before your initial start-up, please make sure that there is no damage caused by transportation. Should 
there be any, consult your dealer and do not use the device. 
 
To maintain perfect condition and to ensure a safe operation, it is absolutely necessary for the user to 
follow the safety instructions and warning notes written in this manual. 
 
Please consider that damages caused by manual modifications to the device are not subject to 
warranty. 
 
This device contains no user-serviceable parts. Refer servicing to qualified technicians only. 
 
 

CAUTION! Be careful with your operations. 

With a dangerous voltage you can suffer 

a dangerous electric shock when touching the wires!

 

 

CAUTION! 

Keep this device away from rain and moisture! 

indoor use only! 

 

FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY  

BEFORE YOUR INITIAL START-UP!

 

 

Summary of Contents for 43031

Page 1: ...LED Tunnel Flower ORDERCODE 43031...

Page 2: ...on Showtec for more excellent lighting products We design and manufacture professional light equipment for the entertainment industry New products are being launched regularly We work hard to keep yo...

Page 3: ...eturn Procedure Claims Description Features and Overview Backside Installation Set Up and Operation Control Modes Built in Programs 1 7 All LEDs ON Automatic Sound Control Mode Master Slave Mode DMX M...

Page 4: ...000 hours will be achieved under normal operational conditions If improving on this lifespan expectancy is of a higher priority place care in providing for lower operational temperatures This may inc...

Page 5: ...le voltage is not higher than stated on the rear panel Make sure that the power cord is never crimped or damaged Check the device and the power cord from time to time Make sure that no side forces can...

Page 6: ...yourself Always let the installation be carried out by an authorized dealer Procedure If the LED Tunnel Flower is lowered from the ceiling or high joists professional trussing systems have to be used...

Page 7: ...description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this check after our ann...

Page 8: ...lue 126 Beam angle 15 9 DMX channels Addressing by dipswitches Operation mode DMX512 Master Slave Sound controlled Built in Programs music controlled via built in microphone Fuse F2A 250V Overview 1 F...

Page 9: ...sconnect from electric mains power supply before cleaning or servicing Damages caused by non observance are not subject to warranty Control Modes There are 4 Modes 1 Built in Programs 1 7 All LEDs ON...

Page 10: ...ter on all sides for air circulation 2 Use a 3 p XLR cable to connect the LED Tunnel Flower The pins 1 Earth 2 Signal 3 Signal 3 Link the units as shown in Fig 3 Connect a DMX signal cable from the fi...

Page 11: ...cess to link the second third and fourth units 4 Set DMX dip switches as follows See Dip Switch setting page 10 LED Tunnel Flower Address Value DMX Dip Switches ON Unit 1 1 Unit 2 10 Unit 3 19 Unit 4...

Page 12: ...Switches ON Unit 5 37 1 3 6 Switch Value 1 1 3 4 6 32 Total sum 37 Explanation Since each unit has 9 channels each address advances 9 values See Address Value above Once address values are determined...

Page 13: ...11...

Page 14: ...Function 132 255 Static Display Channel 4 Cluster 3 0 31 No Function 32 63 Mode 1 64 95 Mode 2 96 127 Mode 3 128 131 No Function 132 255 Static Display Channel 5 Cluster 4 0 31 No Function 32 63 Mode...

Page 15: ...n the course of an acceptance test The operator has to make sure that safety relating and machine technical installations are to be inspected by a skilled person once a year The following points have...

Page 16: ...orrectly but all respond erratically or not at all to the controller The controller is not connected Connect controller 3 pin XLR Out of the controller does not match XLR Out of the first fixture on t...

Page 17: ...peration mode DMX512 master slave Sound controlled auto trigger music controlled via built in microphone Fuse F26A 250V Dimensions 315 x 275 x 365 mm Weight 6 5 kg Minimum distance Minimum distance fr...

Page 18: ......

Reviews: