SHOWTEC 43031 Manual Download Page 1

 
 

 

LED Tunnel Flower 

 

 

 

 

 

            

ORDERCODE 43031 

 

 
 

Summary of Contents for 43031

Page 1: ...LED Tunnel Flower ORDERCODE 43031...

Page 2: ...on Showtec for more excellent lighting products We design and manufacture professional light equipment for the entertainment industry New products are being launched regularly We work hard to keep yo...

Page 3: ...eturn Procedure Claims Description Features and Overview Backside Installation Set Up and Operation Control Modes Built in Programs 1 7 All LEDs ON Automatic Sound Control Mode Master Slave Mode DMX M...

Page 4: ...000 hours will be achieved under normal operational conditions If improving on this lifespan expectancy is of a higher priority place care in providing for lower operational temperatures This may inc...

Page 5: ...le voltage is not higher than stated on the rear panel Make sure that the power cord is never crimped or damaged Check the device and the power cord from time to time Make sure that no side forces can...

Page 6: ...yourself Always let the installation be carried out by an authorized dealer Procedure If the LED Tunnel Flower is lowered from the ceiling or high joists professional trussing systems have to be used...

Page 7: ...description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this check after our ann...

Page 8: ...lue 126 Beam angle 15 9 DMX channels Addressing by dipswitches Operation mode DMX512 Master Slave Sound controlled Built in Programs music controlled via built in microphone Fuse F2A 250V Overview 1 F...

Page 9: ...sconnect from electric mains power supply before cleaning or servicing Damages caused by non observance are not subject to warranty Control Modes There are 4 Modes 1 Built in Programs 1 7 All LEDs ON...

Page 10: ...ter on all sides for air circulation 2 Use a 3 p XLR cable to connect the LED Tunnel Flower The pins 1 Earth 2 Signal 3 Signal 3 Link the units as shown in Fig 3 Connect a DMX signal cable from the fi...

Page 11: ...cess to link the second third and fourth units 4 Set DMX dip switches as follows See Dip Switch setting page 10 LED Tunnel Flower Address Value DMX Dip Switches ON Unit 1 1 Unit 2 10 Unit 3 19 Unit 4...

Page 12: ...Switches ON Unit 5 37 1 3 6 Switch Value 1 1 3 4 6 32 Total sum 37 Explanation Since each unit has 9 channels each address advances 9 values See Address Value above Once address values are determined...

Page 13: ...11...

Page 14: ...Function 132 255 Static Display Channel 4 Cluster 3 0 31 No Function 32 63 Mode 1 64 95 Mode 2 96 127 Mode 3 128 131 No Function 132 255 Static Display Channel 5 Cluster 4 0 31 No Function 32 63 Mode...

Page 15: ...n the course of an acceptance test The operator has to make sure that safety relating and machine technical installations are to be inspected by a skilled person once a year The following points have...

Page 16: ...orrectly but all respond erratically or not at all to the controller The controller is not connected Connect controller 3 pin XLR Out of the controller does not match XLR Out of the first fixture on t...

Page 17: ...peration mode DMX512 master slave Sound controlled auto trigger music controlled via built in microphone Fuse F26A 250V Dimensions 315 x 275 x 365 mm Weight 6 5 kg Minimum distance Minimum distance fr...

Page 18: ......