Manual: ShowNET - Network Interface
Manual: ShowNET - Network Interface
page 22 / 63
page 23 / 63
d) ILDA Streaming
The Laserworld ShowNET interface is capable to act as range extender for ILDA signals by
tranforming an incoming ILDA signal on the ILDA IN interface to a standard UDP network
signal and transferring this signal back to standard ILDA in a receiver unit (obviously an
external ShowNET interface is required as sender for this kind of application!) . Do NOT
send the signal over Wifi, this transmission method is not suitable in a professional envi-
ronment.
Sender-Receiver configuration for ILDA over LAN, range extender use
The sender uses an IP address range between 192.168.2.70 and 192.168.2.85 and trans-
mits the signal to a receiver that has addresses in the range between 192.168.2.50 and
192.168.2.65. The specific IP addresses need to be set with DIP switches. Make sure there
are no other devices in the same network that use the same IP addresses.
Dip switch setting
switch
1
2
3
4
5
6 7 8 9
10
On (1)
/ Off
(0)
0000 -> IP sender: 192.168.2.70 sends to 192.168.2.50
1000 -> IP sender: 192.168.2.71 sends to 192.168.2.51
0100 -> IP sender: 192.168.2.72 sends to 192.168.2.52
1100 -> IP sender: 192.168.2.73 sends to 192.168.2.53
0010 -> IP sender: 192.168.2.74 sends to 192.168.2.54
1010-> IP sender: 192.168.2.75 sends to 192.168.2.55
0110 -> IP sender: 192.168.2.76 sends to 192.168.2.56
1110 -> IP sender: 192.168.2.77 sends to 192.168.2.57
0001 -> IP sender: 192.168.2.78 sends to 192.168.2.58
1001 -> IP sender: 192.168.2.79 sends to 192.168.2.59
0101 -> IP sender: 192.168.2.80 sends to 192.168.2.60
1101 -> IP sender: 192.168.2.81 sends to 192.168.2.61
0011 -> IP sender: 192.168.2.82 sends to 192.168.2.62
1011 -> IP sender: 192.168.2.83 sends to 192.168.2.63
0111 -> IP sender: 192.168.2.84 sends to 192.168.2.64
1111 -> IP sender: 192.168.2.85 sends to 192.168.2.65
sender: 0
receiver: 1
0 1 1 0
0
Example:
Sender IP address setting:
switch
1
2
3
4
5
6
7
8
9
10
On (1) / Off (0) 0
0
0
1
0
0
1
1
0
0
This assigns IP address 192.168.2.78 to the Sender.
The corresponding receiver needs this IP address setting:
switch
1
2
3
4
5
6
7
8
9
10
On (1) / Off (0) 0
0
0
1
1
0
1
1
0
0
This assigns IP address 192.168.2.58 to the receiver.
The only difference between sender and receiver configuration is dip switch 5, which is 0 for the
sender and 1 for the receiver.
6. Power Supply
Always do respect the min / max supply voltages as per technical datasheet.
Both product and packaging are faultless when leaving the factory.
The user of the device must observe the local safety regulations and the warnings in the ope-
rating instructions. Damage caused by improper handling is beyond the control of the manu-
factuerer and the dealer. Therefore, no liability or warranty is assumed.
If changes are made to this operating manual, we cannot inform the customer of these. Please
contact your dealer for further informations.
For service questions please contact your dealer or [email protected].
We reserve the right to make changes. Due to the amount of data, no guarantee can be given
for the correctness of the information.
Registered office:
8574 Lengwil / Switzerland
Company number: CH-440.3.020.548-6
Commercial Registry Kanton Thurgau
CEO: Martin Werner
VAT no. (Switzerland): 683 180
UID (Switzerland): CHE-113.954.889
VAT no. (Germany): DE 258030001
WEEE-Reg.-No. (Germany): DE 90759352
representative according to EMVG:
Ray Technologies GmbH
Managing Director: Martin Werner
Mühlbachweg 2
83626 Valley / Germany