background image

SL BEAM 300 FX

2

About Quickstart Guide

Included Items

Each SL BEAM 300 FX includes the following items:

Figure 1

:  

Included Items

Warnings and Notices

When using electrical equipment

basic safety

 

precautions should

 

always

 

be

 

followed including

 

the

 

following

:

 READ AND FOLLOW ALL SAFETY INSTRUCTIONS

.

D o    n  o  t use outdoors

.

D o    n  o  t mount near gas or electric heaters.

E q  u  i p  ment should be mounted in locations and at heights where it will not readily be subjected to tampering by unauthorized personnel.

T h  e    u  se of accessory equipment not recommended by the manufacturer may cause an unsafe condition.

D o    n  o  t use this equipment for other than intended use.

R e  f e  r   service to qualified personnel.

SAVE THIS DOCUMENT FOR FUTURE REFERENCE! READ COMPLETELY BEFORE INSTALLING AND USING PRODUCT!

WARNING

:

 

You

 

must

 

have

 

access

 

to

 

a

 

main

 

circuit

 

brea ker or other

 

power

 

disconnect device before installing

 

any

 

wiring

Be

 

sure that

power is disconnected by removing fuses or turning the main circuit breaker off before installation. Installing the device with power on may
expose you to dangerous voltages and damage the device. A qualified electrician must perform this installation.

WARNING:

  

 

Refer to National Electrical Code

® 

and local codes for cable specifications

Failure

 

to

 

use proper cable can result in damage

 

to 

equipment or danger to personnel

.

WARNING:

  

 

This equipment is intended for

 

installation

 

in

 

accordance with

 

the

 

National

 

Electric Code

® 

and

 

local regulations

It

 

is

 

also 

intended

 

for

 

installation in indoor applications

 

only

Before any

 

electrical work is performed

,

 

disconnect power

 

at

 

the

 

circuit

 

breaker or 

remove the fuse to avoid shock or damage to the control. It is recommended that a qualified electrician perform this installation.

Service and Maintenance

For all service and maintenance issues, please contact your local Showline office or an Authorized Service Center. 

Power Requirements

The SL BEAM 300 FX operates on AC input voltages from 100 to 240 VAC.

SL BEAM 300 FX 

QuickStart Guide

AC Input Cable 1.5M

Omega Mounts

(

this

 

document

)

This Quickstart Guide is intended for a knowledgeable user to unpack, install, and use SL BEAM 300 FX in a short time period. For the complete 

manual in PDF format, please visit our web site at :

 and click the user manual download link on the product page. The 

www.philips.com/showline

complete manual provides you all information related to accessories, menu structures, DMX channel mapping/modes,and care for your new luminaire. 

SL BEAM 300 FX

 

Q

UICK

S

TART 

G

UIDE

QuickStart Guide

WARNING:  This unit does not contain an ON/OFF switch. Always disconnect power input cable to completely remove power from unit when not in use.

Summary of Contents for SL BEAM 300 FX

Page 1: ...SL BEAM 300 FX ...

Page 2: ...7 7880 Fax 1 214 647 8030 Auckland 19 21 Kawana Street Northcote Auckland 0627 New Zealand Tel 64 9 481 0100 Fax 64 9 481 0101 Asia Unit C 14 F Roxy Industrial Centre No 41 49 Kwai Cheong Road Kwai Chung N T Hong Kong Tel 852 2796 9786 Fax 852 2798 6545 Europe Rondweg zuid 85 Winterswijk 7102 JD The Netherlands Tel 31 0 543 542516 www philips com showline SL BEAM 300 FX QUICKSTART GUIDE SL BEAM 30...

Page 3: ...able specifications Failure to use proper cable can result in damage to equipment or danger to personnel WARNING This equipment is intended for installation in accordance with the National Electric Code and local regulations It is also intended for installation in indoor applications only Before any electrical work is performed disconnect power at the circuit breaker or remove the fuse to avoid sh...

Page 4: ...NG Only connect other SL BEAM 300 FXs to the AC Output Thru connector of a SL BEAM 300 FX Table 2 AC Input Connections describes how to connect power to your SL BEAM 300 FX Field wiring of the SL BEAM 300 FX is straight forward A total of 3 wires conductors is supplied to this unit 100 180 3 50 1 95 4 7 4 8 5 9 6 9 6 9 6 10 7 5 8 110 190 3 18 1 84 160 240 2 19 1 46 150 230 2 34 1 52 140 220 2 50 1...

Page 5: ...ng Application The SL BEAM 300 FX will be equipped with a 1m power cord with bare end for power input and a white 3pin terminal for power output For DMX input and output 2 DMX plugs are installed 4 SL BEAM 300 FX QUICKSTART GUIDE SL BEAM 300 FX QuickStart Guide SAFETY CABLE Is sold separately and recommended for all hanging installation and may be required by national and local codes Use enclosure...

Page 6: ...t type name If DMX is enabled the programmed address will appear after power up SL BEAM 300 FX Home menu settings Edit a Preset Edit a Chase DMX512 Addressing Return to Main Screen LEFT Arrow Button UP Arrow Button OK Check Mark Button DOWN Arrow Button RIGHT Arrow Button LCD Display NOTE Menu rotates with orientation of Luminaire and menu buttons are always in the same position with rotation of m...

Page 7: ...ill be shown Step 2 Press OK Check Mark button to highlight a digit in the DMX address Step 3 Use LEFT and RIGHT arrow buttons to scroll through all digits Step 4 Once at desired dight use UP and DOWN arrows to change highlighted digit Once digit is set use LEFT and RIGHT arrow buttons to set other digits in DMX address Step 5 Once all digits are set in DMX address press OK Check Mark button Step ...

Page 8: ...dustrial Centre No 41 49 Kwai Cheong Road Kwai Chung N T Hong Kong Tel 852 2796 9786 Fax 852 2798 6545 Auckland 19 21 Kawana Street Northcote Auckland 0627 New Zealand Tel 64 9 481 0100 Fax 64 9 481 0101 Europe Rondweg zuid 85 Winterswijk 7012 JD The Netherlands Tel 31 0 543 542516 2015 Philips Group C ...

Reviews: