Range of allowable voltage is ±5%. Rated motor current is effective when the inlet gas temperature 

and ambient temperature is 40°C. Motor current will rise by 6% when inlet gas temperature and 
ambient temperature is 20°C.  Set the motor protection circuit breaker at the rated current value. 

Be sure to connect ground wires properly to prevent electrical shock. 

Current value 

Use the product within the following current values corresponding to the model. 

―2― 

 

Discharge side 

Intake side 

Frequency 

50Hz 

60Hz 

50Hz 

60Hz 

Voltage 

200V 

200/220V 

200V 

200/220V 

U2S-40T 

1.8

  

2.5/2.3

  

1.8

  

2.5/2.3

  

U2S-70T 

3.0

  

4.0/3.8

  

3.0

  

4.0/3.8

  

U2S-150 

7.0

  

8.8/8.5

  

7.0

  

8.8/8.5

  

U2S-220 

10.5

  

14.0/13.0

  

9.0

  

14.0/13.0

  

U2S-370 

18.0

  

18.0/18.0

  

18.0

  

18.0/18.0

  

U2S-750 

26.0

  

33.0/30.0

  

22.0

  

27.0/26.5

  

 