IMPORTANT: 

The manufacturer will not accept liability for any resulting damages caused by the non-observance of 

this manual or any unauthorized modification to the device. 

 

 

Never let the power cord come into contact with other cables! Handle the power cord and all 

connections with the mains with particular caution! 

 

Never remove warning or informative labels from the unit. 

 

Never use anything to cover the ground contact. 

 

Never place any material over the lens. 

 

Never look directly into the light source. 

 

Never leave any cables lying around. 

 

Do not insert objects into air vents. 

 

Do not connect this device to a dimmer pack. 

 

Do not switch the device on and off in short intervals, as this would reduce the device’s life. 

 

Do not touch the device’s housing bare-handed during its operation. Allow the fixture to cool for at 
least 5 minutes before handling. 

 

Do not shake the device. Avoid brute force when installing or operating the device. 

 

Only use device indoors, avoid contact with water or other liquids. 

 

Only operate the fixture after having checked that the housing is firmly closed and all screws are 

tightly fastened. 

 

Only operate the device after having familiarized with its functions. 

 

Avoid flames and do not put close to flammable liquids or gases. 

 

Always keep case closed while operating. 

 

Always allow free air space of at least 50 cm around the unit for ventilation. 

 

Always disconnect power from the mains, when device is not used or before cleaning! Only handle 

the power cord by the plug. Never pull out the plug by tugging the power cord. 

 

Make sure that the device is not exposed to extreme heat, moisture or dust. 

 

Make sure that the available voltage is not higher than stated on the rear panel. 

 

Make sure that the power cord is never crimped or damaged. Check the device and the power 

cord from time to time. 

 

If the lens is obviously damaged, it has to be replaced, so that its functions are not impaired, due to 

cracks or deep scratches. 

 

If device is dropped or struck, disconnect mains power supply immediately. Have a qualified 
engineer inspect for safety before operating. 

 

If the device has been exposed to drastic temperature fluctuation (e.g. after transportation), do not 

switch it on immediately. The arising condensation water might damage your device. Leave the 
device switched off until it has reached room temperature. 

 

If your Showtec device fails to work properly, discontinue use immediately. Pack the unit securely 
(preferably in the original packing material), and return it to your Showtec dealer for service. 

 

For adult use only. Device must be installed out of the reach of children. Never leave the unit running 

unattended. 

 

Never attempt to bypass the thermostatic switch or fuses. 

 

For replacement use fuses of same type and rating only. 

 

The user is responsible for correct positioning and operating of the Pixel Bar. The manufacturer will not 
accept liability for damages caused by the misuse or incorrect installation of this device. 

 

This device falls under protection class I. Therefore it is essential to connect the yellow/green 

conductor to earth. 

 

Repairs, servicing and electric connection must be carried out by a qualified technician. 

 

WARRANTY: Till one year after date of purchase. 

 

 

 

 

Summary of Contents for Pixel Ber 4 COB

Page 1: ...Pixel Bar 4 COB V2 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 41268 MANUAL ENGLISH ...

Page 2: ...uilt in Programs Auto run 9 One Pixel Bar Sound controlled 9 Multiple Pixel Bars Master Slave control 9 Multiple Pixel Bars DMX Control 10 Fixture Linking 11 Data Cabling 11 Control Panel 12 Control Mode 12 DMX Addressing 12 Menu Overview 13 Main Menu Options 14 1 DMX Addressing 14 2 Slave Mode 14 3 Manual Color 14 4 Built in Programs 15 5 Auto Run Mode 15 6 Sound control Mode 15 DMX Channels 16 2...

Page 3: ...atures than in ideal or singular optimum conditions For this reason when all color LEDs are used at their fullest intensity life of the LEDs is significantly reduced If improving your lifespan expectancy is of a higher priority place care in providing for lower operational temperatures This may include climatic environmental and the reduction of overall projection intensity Safety Instructions Eve...

Page 4: ... by the plug Never pull out the plug by tugging the power cord Make sure that the device is not exposed to extreme heat moisture or dust Make sure that the available voltage is not higher than stated on the rear panel Make sure that the power cord is never crimped or damaged Check the device and the power cord from time to time If the lens is obviously damaged it has to be replaced so that its fun...

Page 5: ...hers Rigging Please follow the European and national guidelines concerning rigging trussing and all other safety issues Do not attempt the installation yourself Always let the installation be carried out by an authorized dealer Procedure If the Pixel Bar is lowered from the ceiling or high joists professional trussing systems have to be used Use a clamp to mount the Pixel Bar with the mounting bra...

Page 6: ...kind of truss Connection with the mains Connect the device to the mains with the power plug Always pay attention that the right color cable is connected to the right place International EU Cable UK Cable US Cable Pin L BROWN RED YELLOW COPPER FASE N BLUE BLACK SILVER NULL YELLOW GREEN GREEN GREEN EARTH Make sure that the device is always connected properly to the earth ...

Page 7: ... number 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this check after our announcement that the goods are at their disposal Damage incurred in shipping is the responsibility of the shipper therefore the damage must be reported to the carrier upon receipt of ...

Page 8: ...tion Input voltage 100 240V AC 50 60Hz Drive current 500mA 240V Power consumption 60W max FO full output DMX control via standard DMX controller Onboard Display for easy setup Control DMX 512 Built in Programs Auto Manual Master Slave Sound controlled Beam angle 55 Dimmer 0 100 Strobe 0 20Hz Housing Die cast aluminum powder coat finish Cooling Convection Lens plate Tempered Glass Lux 2 meter Red 1...

Page 9: ...is removed Connect all cables Do not supply power before the whole system is set up and connected properly Always disconnect from electric mains power supply before cleaning or servicing Damages caused by non observance are not subject to warranty Set Up and Operation Follow the directions below as they pertain to your preferred operation mode Before plugging the unit in always make sure that the ...

Page 10: ...light onto firm trussing Leave at least 0 5 meter on all sides for air circulation 02 Always use a safety cable ordercode 70140 70141 03 Plug the end of the electric mains power cord into a proper electric power supply socket 04 When the Pixel Bar is not connected with a DMX cable it functions as a stand alone device 05 Turn on the music If the device is set to SU00 then the Pixel Bar will react t...

Page 11: ... devices 05 Link the units as shown in Fig 04 Connect a DMX signal cable from the first unit s DMX out socket to the second unit s in socket Repeat this process to link the second third and fourth units 06 Supply electric power Plug electric mains power cords into each unit s IEC socket then plug the other end of the mains power cord into proper electric power supply sockets starting with the firs...

Page 12: ...l Bars on a Powercon link 30 fixtures 240V Data Cabling To link fixtures together you must obtain data cables You can purchase DAP Audio certified DMX cables directly from a dealer distributor or construct your own cable If you choose to create your own cable please use data grade cables that can carry a high quality signal and are less prone to electromagnetic interference DAP Audio DMX Data Cabl...

Page 13: ...13 the DMX address of the third Pixel Bar should be 13 12 25 d025 etc Please be sure that you don t have any overlapping channels in order to control each Pixel Bar correctly If two or more Pixel Bars are addressed similarly they will work similarly Controlling After having addressed all Pixel Bar fixtures you may now start operating these via your lighting controller Note After switching on the P...

Page 14: ...13 Ordercode 41268 Pixel Bar 4 COB Menu Overview ...

Page 15: ... this menu you can set the device as a master or slave 01 Press the MODE button until the display shows 02 If the device has not been set to slave it is automatically classified as a master device All slave devices will follow the master s movement 03 If the device has been set to slave it will react the same as its master device 3 Manual Color With this menu you can manually set a desired color 0...

Page 16: ...he values 5 Auto Run Mode With this menu you can set Auto Run mode of the Pixel Bar 01 Press the MODE button until the display shows 02 Press the SETUP button to scroll through the 3 options 03 Press the UP DOWN buttons to change the values Set the speed 01 99 Full Set the flash frequency 0 99 Full Set the number of loops 01 100 6 Sound control Mode With this menu you can set Sound control mode of...

Page 17: ...135 Program 10 136 143 Program 11 144 151 Program 12 152 159 Program 13 160 167 Program 14 168 175 Program 15 176 183 Program 16 184 191 Program 17 192 199 Program 18 200 207 Program 19 208 215 Program 20 216 223 Program 21 224 231 Program 22 232 239 Program 23 240 247 Program 24 248 255 Sound controlled Mode Channel 2 No Function when CH1 is set between 0 55 Channel 2 Speed when CH1 is set betwee...

Page 18: ...er intensity 0 255 Blue from 0 100 Channel 4 Dimmer 0 255 From black to brightest Channel 5 Shutter Strobe CH1 CH2 CH3 or CH4 must be set between 1 255 0 Open 1 255 Strobe effect from slow to fast 0 20 flashes sec 6 Channels Channel 1 Red Dimmer intensity 0 255 Red from 0 100 Channel 2 Green Dimmer intensity 0 255 Green from 0 100 Channel 3 Blue Dimmer intensity 0 255 Blue from 0 100 Channel 4 Red...

Page 19: ...d from 0 100 Channel 5 Green Dimmer intensity 0 255 Green from 0 100 Channel 6 Blue Dimmer intensity 0 255 Blue from 0 100 Channel 7 Red Dimmer intensity 0 255 Red from 0 100 Channel 8 Green Dimmer intensity 0 255 Green from 0 100 Channel 9 Blue Dimmer intensity 0 255 Blue from 0 100 Channel 10 Red Dimmer intensity 0 255 Red from 0 100 Channel 11 Green Dimmer intensity 0 255 Green from 0 100 Chann...

Page 20: ...ion whatsoever If this happens follow the directions below 01 Unplug the unit from electric power source 02 Insert a screwdriver into the slot in the fuse cover Gently pry up the fuse cover The fuse will come out 03 Remove the used fuse If brown or unclear it is burned out 04 Insert the replacement fuse into the holder where the old fuse was Reinsert the fuse cover Be sure to use a fuse of the sam...

Page 21: ...tion Inspect connections and cables Correct poor connections Repair or replace damaged cables Data link not terminated with 120 Ohm termination plug Insert termination plug in output jack of the last fixture on the link Incorrect addressing of the fixtures Check address setting One of the fixtures is defective and disturbs data transmission on the link Bypass one fixture at a time until normal ope...

Page 22: ... kHz IP rating IP 20 Specially designed housing ensures an optimum heat dissipation during operation DMX control via standard DMX controller Onboard Display for easy setup Control DMX 512 Built in Programs Auto Manual color Master Slave Sound controlled Beam angle 55 Dimmer 0 100 Strobe 0 20Hz Housing Die cast aluminium powder coat finish Cooling Convection no fans Lens Plate Tempered Glass Lux 2 ...