background image

 

  

 

 

21 

   

 

42674 

Cameleon Flood 15WW 

DMX Channels 

 
1 DMX Channel 
 
Channel 1 – Dimmer intensity 
0-255 

Gradual adjustment, from dark to brightest 0-100% 

 
2 DMX Channels 
 
Channel 1 – Master Dimmer intensity 
0-255 

Gradual adjustment, from dark to brightest 0-100% 

 

Channel 2 – Linear strobe (CH1 must be set between 1-255 

0-10 

Closed 

11-255 

Strobe flash frequency, from slow to fast (0-15 Hz) 

 
 

Maintenance 

The operator has to make sure that safety-related and machine-technical installations are to be 
inspected by an expert after every year in the course of an acceptance test. 
The operator has to make sure that safety-related and machine-technical installations are to be 
inspected by a skilled person once a year. 
 
The following points have to be considered during the inspection: 
01)

 

All screws used for installing the device or parts of the device have to be tightly connected and 
must not be corroded. 

02)

 

There may not be any deformations on housings, fixations and installation spots. 

03)

 

Mechanically moving parts like axles, eyes and others may not show any traces of wearing. 

04)

 

The electric power supply cables must not show any damages or material fatigue. 

 
The Cameleon Flood 15WW requires almost no maintenance. However, you should keep the unit clean.  
Otherwise, the fixture’s light-output will be significantly reduced. Disconnect the mains power supply, and 
then wipe the cover with a damp cloth. Do not immerse in liquid. Wipe lens clean with glass cleaner and 
a soft cloth. Do not use alcohol or solvents. 
The front lens will require weekly cleaning, as smoke-fluid tends to build up residues, reducing the light-
output very quickly. 
Keep connections clean. Make sure connections are thoroughly dry before linking equipment or 
supplying electric power. 
 

 

Summary of Contents for Cameleon Flood 15WW

Page 1: ...Cameleon Flood 15WW V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 42674 MANUAL ENGLISH ...

Page 2: ...ple Cameleon Floods DMX Control 11 Fixture Linking 12 Data Cabling 12 Control Panel 13 Control Mode 13 DMX Addressing 13 Menu Overview 14 Main Menu Options 15 1 Auto program 15 2 DMX Address DMX Configuration 15 3 Master slave 16 4 Manual mode 16 5 Settings 16 5 1 Curves Select 17 5 2 Dimmer Speed 17 5 3 Dmx Fail 18 5 4 Dmx Sync 18 5 5 Lock 18 5 6 Factory 19 6 Information 19 Optional remote contro...

Page 3: ...tec Cameleon Flood 15WW 1x Schuko to 3 pins IP 65 Power cable 1 5m User manual LED Expected Lifespan LEDs gradually decline in brightness over time HEAT is the dominant factor that leads to the acceleration of this decline Packaged in clusters LEDs exhibit higher operating temperatures than in ideal or singular optimum conditions For this reason when all color LEDs are used at their fullest intens...

Page 4: ... open the device and do not modify the device Do not connect this device to a dimmer pack Do not switch the device on and off in short intervals as this will reduce the device s life Do not touch the device s housing bare handed during its operation housing becomes hot Allow the device to cool for at least 5 minutes before handling Do not shake the device Avoid brute force when installing or opera...

Page 5: ...chase Operating Determinations This device is not designed for permanent operation Consistent operation breaks will ensure that the device will serve you for a long time without defects The minimum distance between light output and the illuminated surface must be bigger than 1 meter In order to eliminate wear and improve the device s lifespan during periods of non use completely disconnect from po...

Page 6: ...w the installation site is secured and that there are not any unauthorized people around The Cameleon Flood 15WW can be placed on a flat stage floor or mounted to any kind of truss with a clamp Improper installation can cause serious injuries and or damage of property Connection with the mains Connect the device to the mains with the power plug Always check if the right color cable is connected to...

Page 7: ...er 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this check after our announcement that the goods are at their disposal Damage incurred in shipping is the responsibility of the shipper therefore the damage must be reported to the carrier upon receipt of merch...

Page 8: ...ion rate IP 65 Lens Plate Tempered Glass Control DMX Auto program Master slave Manual Dimmer 0 100 Strobe 0 15Hz Housing Die Cast Black Aluminum Cooling Convection no fans Connections Dedicated Power cable IP 65 IN OUT Data IP 65 IN OUT Dimensions 330 x 100 x 210 mm LxWxH incl bracket Weight 5 2 kg Optional accessories 42698 Power end cap set Male female for Cameleon series 42699 Data end cap set ...

Page 9: ... white 02 IR sensor 03 Mounting bracket Backside Fig 02 04 Special mini 3 pin DMX cable IN IP 65 05 Safety eye 06 Special mini 3 pin DMX cable OUT IP 65 07 Special mini 3 pin power cable IN IP 65 08 OLED Display control buttons 09 Special mini 3 pin power cable OUT IP 65 ...

Page 10: ...m Manual mode Master slave DMX 512 1CH 2CH One Cameleon Flood Auto program 01 Fasten the effect light onto firm trussing Leave at least 0 5 meter on all sides for air circulation 02 Always use a safety cable ordercode 70140 70141 03 Plug the end of the electric mains power cord into a proper electric power supply socket 04 When the Cameleon Flood is not connected with a DMX cable it functions as a...

Page 11: ...al 04 Link the units as shown in Fig 03 Connect the first unit s DMX out socket with the second unit s in socket using the 42707 427076 DMX Extension cable Link the second third and fourth units using the 42707 427076 DMX Extension cable You can use the same functions on the master device as described on pages 15 and 16 Auto program Manual mode This means that you can set your desired operation mo...

Page 12: ...in socket using the 42707 427076 DMX Extension cable Link the second and third units using the 42707 427076 DMX Extension cable 05 Supply electric power Plug electric mains power cords into each unit s special IP65 power IN socket then plug the other end of the mains power cord into proper electric power supply sockets starting with the first unit Do not supply power before the whole system is set...

Page 13: ...e less prone to electromagnetic interference DAP Audio DMX Data Cables DAP Audio Basic microphone cable for allround use bal XLR M 3 pin XLR F 3 pin Ordercode FL01150 1 5 m FL013 3 m FL016 6 m FL0110 10 m FL0115 15 m FL0120 20 m DAP Audio X type data cable XLR M 3 pin XLR F 3 pin Ordercode FLX0175 0 75 m FLX01150 1 5 m FLX013 3 m FLX016 6 m FLX0110 10 m DAP Audio cable for the demanding user with ...

Page 14: ...eleon Flood should be 3 2 5 005 etc Please be sure that you do not have any overlapping channels in order to control each Cameleon Flood correctly If two or more Cameleon Floods are addressed similarly they will work similarly Controlling After having addressed all Cameleon Flood fixtures you may now start operating these via your lighting controller Note After switching on the Cameleon Flood will...

Page 15: ...14 42674 Cameleon Flood 15WW Menu Overview The Cameleon Flood 15WW will show the current software version and actual temperature at start up ...

Page 16: ...eed The adjustment range is between from slow to fast 06 If you choose Strobe press the SET button to open the submenu 07 Press the UP DOWN buttons to increase decrease the strobe frequency The adjustment range is between from OFF to high strobe frequency 2 DMX Address DMX Configuration In this menu you can set the device s DMX starting address and choose a DMX configuration 01 While in the main m...

Page 17: ...y classified as a master device 07 Press the SET button to confirm your choice 4 Manual mode In this menu you can set the light intensity of the device 01 While in main menu press the UP DOWN buttons until the display shows Manual 02 Press the SET button to open the menu 03 Press the UP DOWN buttons to set the intensity The adjustment range is between 04 Press the SET button to confirm your choice...

Page 18: ...the UP DOWN buttons to choose the desired dimming curve out of the 4 available options 04 Press the SET button to confirm your choice 5 2 Dimmer Speed In this menu you can adjust the dimming speed of the device 01 Press the UP DOWN buttons to choose Dimmer Speed 02 Press the SET button to open the menu the display will show 03 Press the UP DOWN buttons to choose between Fast or Smooth 04 Press the...

Page 19: ...e menu the display will show 03 Press the UP DOWN buttons to select On or Off 04 The Sync option is a tool which helps to keep multiple fixtures synchronized when using them in master slave mode 05 If you choose On the synchronization function is activated this is recommended 06 If you choose Off the synchronization function is not activated 07 Press the SET button to confirm your choice 5 5 Lock ...

Page 20: ...o select Yes or No 04 If you choose Yes and confirm it with the SET button the device will be reset to its factory default settings 05 If you choose No the device will keep current settings 6 Information In this menu you can view several info from the device 01 While in main menu press the UP DOWN buttons to choose Information 02 Press the SET button to open the menu 03 You can now view the curren...

Page 21: ... control the device with the remote control Built in program 01 Press the button to activate the Built in program mode 02 Press the button to set the program speed 03 Press the and buttons to increase decrease the program speed The adjustment range is between 01 100 04 Press the button to set the strobe frequency 05 Press the and buttons to increase decrease the strobe frequency The adjustment ran...

Page 22: ... screws used for installing the device or parts of the device have to be tightly connected and must not be corroded 02 There may not be any deformations on housings fixations and installation spots 03 Mechanically moving parts like axles eyes and others may not show any traces of wearing 04 The electric power supply cables must not show any damages or material fatigue The Cameleon Flood 15WW requi...

Page 23: ...o your Showtec dealer 04 If all of the above appears to be O K plug the unit in again 05 If you are unable to determine the cause of the problem do not open the Cameleon Flood as this may damage the unit and the warranty will become void 06 Return the device to your Showtec dealer No Response to DMX Suspect the DMX cable or connectors a controller malfunction a light effect DMX card malfunction 01...

Page 24: ...n Inspect connections and cables Correct poor connections Repair or replace damaged cables Data link not terminated with 120 Ohm termination plug Insert termination plug in output jack of the last fixture on the link Incorrect addressing of the fixtures Check address setting One of the fixtures is defective and disturbs data transmission on the link Bypass one fixture at a time until normal operat...

Page 25: ...chanical effects Light source 15 x 8W Power LED Warm white Output 4367 Lumen Beam angle 39 Max distance 10m Colour temperature 3000K CRI 80 Lens Plate Tempered Glass Connections Dedicated Power cable IP 65 IN OUT Data IP 65 IN OUT Dimmer 0 100 Strobe 0 15Hz Control DMX Auto program Master slave Manual Cooling Convection no fans Housing Die cast Black Aluminum Max ambient temperature ta 40 C Max ho...

Page 26: ...25 42674 Cameleon Flood 15WW Dimensions ...

Page 27: ...26 42674 Cameleon Flood 15WW ...

Page 28: ... 2018 Showtec ...