background image

Voltage

 

operating values

 display on upper L1-L2-L3 and 

synchronous

 over voltage faults code display on the lower

L1-L2- L3

U> faults display(synchronous)

V

V

V

A

A

A

Voltage

 

operating values

 display on upper L1-L2-L3 and 

asynchronous

 over voltage faults code display on the lower

L1-L2- L3

U> faults display(asynchronous)

V

V

V

A

A

A

U< faults display(synchronous)

V

V

V

A

A

A

U< faults display(asynchronous)

V

V

V

A

A

A

A

Reset/start delay display(synchronous)

V

V

V

A

A

A

Reset/start delay display(asynchronous)

V

V

V

A

A

A

I> faults display(synchronous)

V

V

V

A

A

A

I> faults display(asynchronous)

V

V

V

A

A

Display of

 phase sequence fault

V

V

V

A

A

A

Voltage

 

operating 

values

 

display  on  upper  L1

-

L2

-

L3

 

and 

asymmetry fault code 

d

isplay

 on lower L2 during

 

the

 

counting of

 

start

 

delay; After the delay is over, the

 

output relay closes

.

Display of

 

(only synchronous)

asymmetry fault

 

V

V

V

A

A

A

Display of 

(synchronous)

continuous I> faults

V

V

V

A

A

A

Display of 

(asynchronous)

continuous I> faults

 

Display for continuous overcurrent faults after reset/start delay is over.

  overcurrent faults times is more than preset times.

V

V

V

A

A

A

Voltage

 

operating values

 display on upper L1-L2-L3 and delay 

time flashes

 on the lower L3 during

 

the

 

counting of

 

start

 

delay; After 

the delay is over, the

 

output relay closes

.

Voltage

 

operating values

 display on upper L1-L2-L3 and delay 

time flashes

 on the lower L1-L2- L3 during

 

the

 

counting of

 

start

 

delay; After the delay is over, the

 

output relay closes

.

Voltage

 

operating values

 display on upper L1-L2-L3 and 

synchronous

 under voltage faults code display on the lower

L1-L2- L3

Voltage

 

operating values

 display on upper L1-L2-L3 and 

asynchronous

 under voltage faults code display on the lower

L1-L2- L3

Voltage

 

operating values

 display on upper L1-L2-L3 and 

synchronous

 over current faults code display on the lower

L1-L2- L3

Voltage

 

operating values

 display on upper L1-L2-L3 and 

asynchronous

 over current faults code display on the lower

L1-L2- L3

 

Display for continuous overcurrent faults after reset/start delay is over.

  overcurrent faults times is more than preset times.

Start the relay after reset manually.

Disconnect the overload device 

Start the relay after reset manually.

Disconnect the overload device 

Display L1-L3-L2 when phase failure fault occurs. User can 
change the position of L2 and L3 after disconnected supply.

-3-

Summary of Contents for EVP-3PH

Page 1: ...0 ON OFF ON OFF 20V 99V OFF 0 1s 350V 0 02s 120V 0 5s 120V 0 1s 10s 450V Protection degree IP20 Pollution degree 3 Electrical life Altitude Operating temperature Storage temperature Mechanical life 105 106 2000m 5 C 40 C 25 C 55 C Voltage measurement accuracy 1 over the whole range Rated insulation voltage Humidity Output contact 1NO Operation voltage range AC 50V 400V Rated frequency 50 60Hz 220 ...

Page 2: ... turn off the function Phase sequence setting Change the setting states by pressing keys OFF turn off the function ON turn on the function Auto reset setting Change the setting states by pressing keys OFF turn off the function ON turn on the function Long press can increase or decrease repidly The relay will automatically exit from the menu and not save the modified value if not pressing the keys f...

Page 3: ...times is more than preset times V V V A A A Voltage operating values display on upper L1 L2 L3 and delay time flashes on the lower L3 during the counting of start delay After the delay is over the output relay closes Voltage operating values display on upper L1 L2 L3 and delay time flashes on the lower L1 L2 L3 during the counting of start delay After the delay is over the output relay closes Volt...

Page 4: ...Ta Overcurrent faults trip delay FUNCTION DIAGRAMS If a voltage fault was detected when the reset start delay of relay is counting the output relay opens and faults indication LED lights up Voltage faults if input voltage was detected to have returned to Hys after tripped for voltage faults the relay will reset automatically and begin the counting of reset start delay Current faults After the rela...

Reviews: