-6-
Model W1742/W1742S (Mfg. Since 7/12)
Grounding Requirements
This machine MUST be grounded. In the event of certain
types of malfunctions or breakdowns, grounding provides
a path of least resistance for electric current to travel—in
order to reduce the risk of electric shock.
Improper connection of the equipment-grounding wire will
increase the risk of electric shock. The wire with green
insulation (with/without yellow stripes) is the equipment-
grounding wire. If repair or replacement of the power
cord or plug is necessary, do not connect the equipment-
grounding wire to a live (current carrying) terminal.
Check with a qualified electrician or service personnel
if you do not understand these grounding requirements,
or if you are in doubt about whether the tool is
properly grounded. If you ever notice that a cord or
plug is damaged or worn, disconnect it from power, and
immediately replace it with a new one.
Grounding Prong
Current Carrying Prongs
6-20 PLUG
GROUNDED
6-20 RECEPTACLE
Figure 2.
NEMA 6-20 plug & receptacle.
This machine is equipped with a power cord that has an
equipment-grounding wire and NEMA 6-20 grounding plug.
The plug must only be inserted into a matching receptacle
(see
=`^li\
) that is properly installed and grounded in
accordance with local codes and ordinances.
For 240V Connection
The machine must be properly set up
before it is safe to operate. DO NOT
connect this machine to the power
source until instructed to do so later in
this manual.
Extension Cords
We do not recommend using an extension cord with this
machine. Extension cords cause voltage drop, which may
damage electrical components and shorten motor life.
Voltage drop increases with longer extension cords and
the gauge smaller gauge sizes (higher gauge numbers
indicate smaller sizes).
Any extension cord used with this machine must contain a
ground wire, match the required plug and receptacle, and
meet the following requirements:
Minimum Gauge Size at 240V ...................... 12 AWG
Maximum Length (Shorter is Better) ................50 ft.
No adapter should be used with the
required plug. If the plug does not fit
the available receptacle or the machine
must be reconnected to a different
type of circuit, the reconnection must
be made by an electrician or qualified
service personnel and it must comply
with all local codes and ordinances.
Summary of Contents for W1742
Page 26: ......
Page 28: ......
Page 76: ...N GcXe i n k_ Xjk ife N e j G8IKJ XY e k X iXd G8IKJ...
Page 77: ...N GcXe i n k_ Xjk ife N e j G8IKJ XY e k GXikj C jk...
Page 78: ...N GcXe i n k_ Xjk ife N e j G8IKJ X jkfZb GXikj X iXd...
Page 79: ...0 N GcXe i n k_ Xjk ife N e j G8IKJ X jkfZb GXikj C jk...
Page 80: ...N GcXe i n k_ Xjk ife N e j G8IKJ 0 0 0 0 XiYfo X iXd...
Page 81: ...N GcXe i n k_ Xjk ife N e j G8IKJ XiYfo GXikj C jk...
Page 82: ...N GcXe i n k_ Xjk ife N e j G8IKJ 0 0 0 Cfn i KXYc X iXd GXikj C jk...
Page 83: ...N GcXe i n k_ Xjk ife N e j G8IKJ 0 0 Lgg i KXYc X iXd GXikj C jk...
Page 85: ...N GcXe i n k_ Xjk ife N e j G8IKJ CXY c C jk...
Page 89: ......
Page 90: ......