8
VAL6 KBE5S & KBE5L Trouble Shooting
No.
Possible Cause
How to check
Result
Remedy
43
Flame monitor is
defective
Disconnect flame
monitor connector
(CN11) from circuit
board, then check
transition of resistance by
changing quantity of light
into flame monitor
If the valu of resistance is
nonstandard, the flame
monitor is defective
Standard: balck-black
dark: over 2M
Ω
light: under 10K
Ω
Replace a flame
monitor
44
Run out of fuel
Check whether fuel is in
tank
Refueling
45
Nozzle is clogged
Replace a nozzle
Clean and flush the
tank with kerosene,
alcohol or acetone
46
Fuel filter (element) is
clogged
Check with eyes whether
or not the fuel filter is
dirty or fouled
Replace a fuel filter
47
Air intake of fuel
gauge is clogged
Check if air intake of fuel
gauge is clogged with
dust
If air intake of fuel gauge
is clogged, fuel flow is
insufficient by pressure
drop in fuel tank
Clear an air intake of
fuel gauge
48
Over voltage is being
detected
Change the power source
or confirm whether the
voltage of power source
or generator is correct
Find a cause of over
voltage and take
away them
Combustion is not stable
49
Nozzle is clogged
Replace a nozzle
Clean and flush the
tank with kerosene,
alcohol or acetone
50
Fuel pump is clogged
or defective
Loose the brass nut, then
switch on and check
whether fuel comes out
(place a pan under the
pump)
If no fuel is pump up or
fuel is not flowing at
least 2" high, the fuel
pump is clogged or
defective (see Exhibit A
"How to restore the fuel
Replace a fuel pump
Clean and flush the
tank with kerosene,
alcohol or acetone
Overvoltage lamp is NOT lit
Overvoltage lamp is lit
air intake
8
All manuals and user guides at all-guides.com