SPECIFICATION
MODEL﹕PDN-48-48A STANDARD: 12V—4.0A
4-6 . Drop test:
Products shall be dropped from a height of 1 m onto a horizontal surface consists of
hardwood at 13mm thick ,mounted on two layers of plywood each
19mm to 20mm thick ,all supported on a concrete or equivalent non-resilient
floor . upon conclusion of test, the equipment need not be operational.
4-7 . Cord bending test:
The cord shall withstand a weight of 200g, when swung from left to right at
An angle of 120 deg. For testing total of 1000 times.
5. SAFETY AND EMC:
5-1.
SAFETY:
Certificate standards
UL/CUL
UL60950-1 & UL60065
meet
GS
EN60950 & EN60065
meet
CE
IEC60950 & IEC60065
meet
CB
IEC60950 & IEC60065
meet
CCC GB4943&GB8898
meet
PSE J60950/J55022/J60065
No meet
Australia AS/NZS60950/AS/NZS60065
meet
5-2. EMI: Meet FCC part 15 Class B/CISPR part 22,Class B/CE/3C.
5-3. EMS:
Test Item
Test specification IEC
standards
ESD
Contact :4KV / AIR :8KV
IEC61000-4-2
RF FR:26MHz-1.0GHz,Field
Strength:3V/M IEC61000-4-3
EFT
2KV ON AC power line
IEC61000-4-4
SURGE
1KV(L-N) & 2KV(L-PE,N-PE)
IEC61000-4-5
CS 3V/M
IEC61000-4-6
DIPS
0% 250 Cycle ,40% 5 cycle,70% 5 cycle
IEC61000-4-11
6. MECHANICAL CHARACTERISTICS:
6-1. Physical size: (L)111mm*(W)52mm*(H)32mm
6-2
.
Enclosure material :
94V-1
(
min
)
PC+ABS black
6-3. Net weight: 240g+/-5g
6-4. AC socket: IEC320 C14.
6-5 Output cable:
AWG#18/1C+1 UL1185 *1500mm
(
min
)
BLACK
6-6. Output plug:
(OD)5.5*(ID)2.1* (L)10
mm
(tuning fork)
7. OTHER
7-1.
Operating direction: Green LED direction
ITEM DATE PAGE
REV.
adapter
2009.06.18
5 of 15
01
第 24 页,共 45 页