Shinybow USA SB-5544LCM Instruction Manual Download Page 2

SAFETY INFORMATION

1.  To ensure the best results from this product, please read this manual and all other documentation before operating your equipment. 

Retain all documentation for future reference.

2.  Follow all instructions printed on unit chassis for proper operation.

3.  To reduce the risk of fi re, do not spill water or other liquids into or on the unit, or operate the unit while standing in liquid.

4.  Make sure power outlets conform to the power requirements listed on the back of the unit. Keep unit protected from rain, water and  

excessive moisture.

5.  Do not attempt to clean the unit with chemical solvents or aerosol cleaners, as this may damage the unit. Dust with a clean dry cloth.

6.  Do not use the unit if the electrical power cord is frayed or broken. The power supply cords should be routed so that they are not 

likely to be walked on or pinched by items placed upon or against them, paying particular attention to cords and plugs, convenience 
receptacles, and the point where they exit from the appliance.

7.  Do not force switched or external connections in any way. They should all connect easily, without needing to be forced.

8.  Always operate the unit with the AC ground wire connected to the electrical system ground. Precautions should be taken so that the 

means of grounding of a piece of equipment is not defeated.

9.  AC voltage must be correct and the same as that printed on the rear of the unit. Damage caused by connection to improper AC 

voltage is not covered by any warranty.

10.  Turn power off and disconnect unit from AC current before making connections.

11.  Never hold a power switch in the “ON” position.

12.  This unit should be installed in a cool dry place, away from sources of excessive heat, vibration, dust, moisture and cold. Do not use 

the unit near stoves, heat registers, radiators, or other heat producing devices.

13.  Do not block fan intake or exhaust ports. Do not operate equipment on a surface or in an environment which may impede the normal 

fl ow of air around the unit, such as a bed, rug, carpet, or completely enclosed rack. If the unit is used in an extremely dusty or smoky 
environment, the unit should be periodically “blown free” of foreign dust and matter.

14.  To reduce the risk of electric shock, do not remove the cover. There are no user serviceable parts inside. Refer all servicing to 

qualifi ed service personnel. There are no user serviceable parts inside.

15.  When moving the unit, disconnect input ports fi rst, then remove the power cable; fi nally, disconnect the interconnecting cables to 

other devices.

16.  Do not drive the inputs with a signal level greater than that required to drive equipment to full output.

17.  The equipment power cord should be unplugged from the outlet when left unused for a long period of time.

18.  Save the carton and packing material even if the equipment has arrived in good condition. Should you ever need to ship the unit, 

use only the original factory packing.

19.  Service Information Equipment should be serviced by qualifi er service personnel when:

 

 

A. The power supply cord or the plug has been damaged.

 

 

B. Objects have fallen, or liquid has been spilled into the equipment.

 

 

C. The equipment has been exposed to rain

 

 

D. The equipment does not appear to operate normally, or exhibits a marked change in performance

 

 

E. The equipment has been dropped, or the enclosure damaged.

THIS SAFETY INFORMATION IS OF A GENERAL NATURE AND MAY BE SUPERSEDED BY INSTRUCTIONS CONTAINED WITHIN THIS MANUAL

Summary of Contents for SB-5544LCM

Page 1: ...udio Matrix Switcher Series Thank you for purchasing the SB 5544LCM 4x4 Composite Video Audio Matrix Switcher You will find this unit easy to install and highly reliable but it is essential that you read this manual thoroughly before attempting to use 4x4 Composite Video and Audio Matrix Switcher MULTIMEDIA AUDIO AND VISUAL ...

Page 2: ...ion 12 This unit should be installed in a cool dry place away from sources of excessive heat vibration dust moisture and cold Do not use the unit near stoves heat registers radiators or other heat producing devices 13 Do not block fan intake or exhaust ports Do not operate equipment on a surface or in an environment which may impede the normal flow of air around the unit such as a bed rug carpet o...

Page 3: ...ile in any form or by any means electronic mechanical magnetic optical chemical manual or otherwise without express written permission and consent Copyright 1997 All Rights Reserved Version 1 2 MAR 2014 TRADEMARK ACKNOWLEDGMENTS All products or service names mentioned in this document may be trademarks of the companies with which they are associated CONTENTS INTRODUCTION 1 FEATURES SPECIFICATIONS ...

Page 4: ...4 inputs To 4 outputs Audio Video Matrix Switcher I O Signals Video Composite Video 0 5 1 0 Vpp 75Ohms RCA Yellow Audio Stereo Audio AR AL Via 2x RCA connector Red White Video Bandwidth 450MHz 3db 200mVp p Audio specification 20Hz 20KHz Source Status Automatically scan sources Inputs via LED Low all hostile crosstalk 83 db 5MHz Gain control 60MHz 0 1 db gain flatness IR Frequency 38Khz IR External...

Page 5: ...annel shows which input source is assigned 4 DESTINATION SELECT BUTTONS Separate outputs 1 thru 4 select buttons are provided for each destination assignment Routing can be Source to Destination or one source to multiple destinations Example Press Destination 1 3 4 then press Source 2 will route Input 2 to Output 1 3 4 respectfully 5 SOURCES SELECT DOWN BUTTONS Separate inputs 1 thru 4 select butt...

Page 6: ...hannels Either destinations Press OFF button followed by any Destination channel Press 1 thru 8 output destination The display will show 0 for the selected channel indicating no video selected 10 FUNCTION KEY RECALL The system will show previously stored presets up to a total of 8 Presets are stored in local memory using Source keys 1 thru 4 or Destination keys 1 thru 4 as the memory preset locati...

Page 7: ...on Configure desired matrices Press MEMORY button Press 1 thru 4 on either Source or Destination row Press ENTER to ready memory location Or press MEMORY again to cancel operation Operation completes Note Operation will abort if no keys are dressed within 5 seconds 13 FUNCTION KEY LOCK Press and hold LOCK button for two seconds lockout the front panel Press and hold LOCK button for two seconds to ...

Page 8: ...r polarity 12Volt DC power supply 2A Max 2 IR EXTENDER CONTROL Support one of IR Extender IR input Extend distance maximum 300 M 1000 ft Note DO NOT install or remote any connections while the power is ON 3 RS 232 CONNECTION RS 232 control port to allow for interfacing to a PC such as a computer or touch panel control to the switcher via this DB 9pin Female connector for serial RS 232 control 4 IN...

Page 9: ...iate input source by using the front panel input 1 4 select buttons The supplied IR remote control Or through the RS 232 serial communications port Upon power up the switcher will return to its last used setting before Powered down REMOTE CONTROL IR REMOTE SW 5544LCM IR PCB RA 02 IR CODE 20DF 1 2 SWITCH POWER ON or OFF Controller with a power ON and OFF 3 OUTPUTS 1 4 OUTPUT SELECTION Press the des...

Page 10: ... DESTINATION 1 20DF 01EF SOURCE 1 20DF 01FE DESTINATION 2 20DF 02DF SOURCE 2 20DF 02FD DESTINATION 3 20DF 03CF SOURCE 3 20DF 03FC DESTINATION 4 20DF 04BF SOURCE 4 20DF 04FB For example Select Destination 1 to show Source 1 4 The IR Data Code list when press Destination then press Source Press Destination 1 Source 1 20DF 01EF 20DF 01FE Press Destination 1 Source 2 20DF 01EF 20DF 02FD Press Destinat...

Page 11: ...r plug You must use a 3 conductor plug aka stereo plug Using a 2 conductor plug will short out the power supply Always make connections with the switcher power off When you plug the External IR extender into the switcher the front panel IR receiver remains active P O W E R IN P U T 1 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 HDM I MAT R IX S WIT C HE R O N O F F IN P U T 2 IN P U T 3 IN P U T 4 S W IR SB 10...

Page 12: ...01C Maximum Distance 6 feet 2 meters SB 101C IR Tx SB 101 IR Transmitter Set Note The External IR jack has voltage on the Ring portion of a 3 conductor plug You must use a 3 conductor plug aka stereo plug Using a 2 conductor plug will short out the power supply Always make connections with the switcher power off When you plug the External IR extender into the switcher the front panel IR transmitte...

Page 13: ...river V2 0 1 The ShinybowUSA switcher can be controlled via the RS 232 serial control port to allow for interfacing to a PC or similar third party control system The serial communication parameters are 9600 baud 8 bit No Parity and 1 stop bit this is often referred to as 9600 8N1 When the unit recognizes a complete command it will perform the requested action there is no delimiter character requir...

Page 14: ...system INPUTS 1 4 PORT HD SOURCE SIGNALS COMPOSITE VIDEO Composite Video connector with RCA AUDIO Stereo Audio AR AL connector with RCA OUTPUT 1 4 PORT HDTV DISPLAY SIGNALS COMPOSITE VIDEO Composite Video connector with RCA AUDIO Stereo Audio AR AL connector with RCA SB 5544LCM SUPPORT COMPOSITE FOUR INPUTS MATRIX TO FOUR SWITCH OUTPUTS SUPPORT CONTROL IR RS 232 INTERFACE SYSTEM PORTS 12 ...

Page 15: ... United States ofAmerica SHINYBOWUSA makes no representation that materials pertaining to the Product are appropriate or available for use in other locations other than the shipping address you provided with respect thereto You are advised that the Product may be subject to U S export controls Disclaimers and Limitation of Liability SHINYBOWUSA may change or modify the Product at any time from tim...

Page 16: ...122 Rose Ln Suite 303 Frisco Texas 75034 1 877 SHINY USA 1 877 744 6987 1 972 377 2508 sales shinybowusa com MULTIMEDIA AUDIO AND VISUAL www shinybowusa com ...

Reviews: