6.5
Changing the Display
Display selection procedure
㽲
Press the
㵰
MENU
㵱
key to indicate "
" , and press
㩷
the
㵰
ENT
㵱
key.
㽳
Use the
㵰
㵱
key to select a required display screen from the menu below. Press the
㵰
ENT
㵱
key.
㽴
"
䂔
" is indicated in the case of manual display. Use the
㵰
㵱
key to select the channel
number.
Press the
㵰
ENT
㵱
key.
㩷
“
”(AUTO)
䋺
Auto display
㩷
“
”(MAN)
䋺
Manual display
㩷
“
”(DATE)
䋺
Date display
㩷
“
”(TIME)
䋺
Time display
㩷
“
”(OFF)
䋺
Display off
6.5.1 Auto Display
㧨
㧪
Indicates the process variable of each channel sequentially at intervals of 2.4 seconds.
(Data renewal period 120ms.)
6.5.2 Manual Display
㧨
㧪
Indicates the Process variable of the specific channel, it updates every measurement cycle(120ms).
The data is the same as Auto display.
Pressing the
㵰
ENT
㵱
key changes the indicated channel number (it increments).
6.5.3 Date Display
㧨
㧪
Indicates the month and day. Leap year adjustment is automatic.
㩷
Example of October 18
6.5.4 Time Display
㧨
㧪
Indicates hour and minute.
㩷
Example
of
12:15
6.5.5 Display Off
㧨
㧪
Turns off the process variable display. Key operation is the same as usual. To switch to other display,
take steps
㽲
through
㽴
mentioned above.
Process Variable (5-digt)
Channel Number (1-digit)
䌈
H : High limit Alarm
L : Low limit Alarm
Month
㩷㩷㩷㩷㩷㩷
Day
Hour
㩷㩷㩷㩷㩷㩷
Minute
i
i