43(50)
5.
Trouble-shooting
Failures
Possible reasons
Solutions
LCD displays nothing
after switch on power
and press ON/OFF
key.
Did not connect through power
supply.
Main switch broken.
Power supply wires problems.
Control circuit fuse melt.
Transformer broken.
Connect through power supply.
Replace main switch.
Check electrical wires.
Fix the fuse.
Replace the transformer.
Phase alarm.
Power supply low voltage.
Phase shortage.
Phase reversal.
PCB problems.
Check power supply.
Check power supply.
Exchange two of the wires of power
supply.
Replace the PCB.
Pump overload.
Abnormal fluctuations of power
supply.
Pump blocked.
Pump motor problems.
Overload relay (F1) setting value
error.
Check power supply.
Check the pump.
Check pump motor.
Set the setting current of overload relay
to equal to 1.1 times of motor rated
current. Please refer to Mian
Components for detailed description of
overload relaly.
Reset overload relay:
Wait for one minute, then press the blue
button to reset.
EGO overheat.
EGO temperature setting
mistakes.
EGO poor temperature detecting.
Heater contactor K1 and K2
problems.
Correctly set EGO temperature. (EGO
temperature setting value= temperature
setting value+10
℃
)
Replace EGO.
Replace the contactor.
Low liquid level.
Oil shortage.0
Fill high temp. oil.
Temp. window displays
“
----
“
Abnormal sensor.
Check and repair sensor.
Once running, pump
output indicator
lightens but pump
cannot start. Afetr a
while pump still fails to
run.
PCB output relay problems.
Electrical circuit problems.
Check or replace the PCB.
Check electrical circuit.
Differences between
setting temperature
and actual
temperature is too big.
Too short time after machine
startup.
Temperature parameter setting
error.
Cooling water valve problems.
Wait for a while.
Check temperature parameters.
Please refer to the standard manual of
setting parameters.
Replace solenoid valve.
Temperature can't rise
up.
Heater contactor problems.
Heater problems.
Thermocouple problems.
PCB output point problems.
Replace the contactor.
Replace pipe heater.
Replace thermocouple.
Check and repair PCB.
Summary of Contents for STM-1213-HPW
Page 1: ...STM PW Series High Temp Water Heater Date Apr 2013 Version Ver B English ...
Page 2: ......
Page 23: ...23 50 2 3 2 Control Circuit STM 940HPW 230V Picture 2 5 Control Circuit STM HPW 230V ...
Page 27: ...27 50 2 3 6 Main Circuit STM 940HPW 400V Picture 2 8 Main Circuit STM 940HPW 400V ...
Page 28: ...28 50 2 3 7 Control Circuit STM 940HPW 400V Picture 2 9 Control Circuit STM HPW 400V ...