13(50)
1.4.2 Signs and Labels
Regularly clean the filter screen in
the copper screw to avoid blockage
and as well ensure an excellent
working performance.
This is to indicate motor rotating
direction. When phase reversal
happens, the alarm sounds and
indicator on control panel will
indicate.
Please exchange the place of two of
the electrical wires to solve this
problem.
High voltage! Electrical shock may
happen. Carefulness is required from
the operator.
Attentions!
This is general warnings which
operators should pay attention to.
From mould: connector for
circulating water/oil coming from
mould.
Pump pressure meter: indicating
actual pressure of system.
To mold: connector for circulating
water/ oil to go to mould.