26(29)
P
Heating ratio
Rang:1-100
℃
Default:40
℃
I
Integral
Rang:0-999S
Default:120S
D
Differential
Rang:0-999S
Default:20S
OTP
Overheat temp.
protection
(SV+F-05)
Rang:2-50
℃
Default:15
℃
100C
HCLE
Heating cycle
Rang:15-60S
Default:15S
OFF1
Mon. off time
00:00=OFF
OFF2
Tues. off time
00:00=OFF
OFF3
Wed. off time
00:00=OFF
OFF4
Thur. off time
00:00=OFF
OFF5
Fri. off time
00:00=OFF
OFF6
Sat. off time
00:00=OFF
OFF7
Sun. off time
00:00=OFF
ON 1
Mon. start time
00:00=OFF
ON 2
Tues. start
time
00:00=OFF
ON 3
Wed. start time
00:00=OFF
ON 4
Thur. start
time
00:00=OFF
ON 5
Fri. start time
00:00=OFF
ON 6
Sat. start time
00:00=OFF
ON 7
Sun. start
time
00:00=OFF
TIME
Current
Time(hr,min)
RON
Intermittent run ON
time
Rang :30-600 (Min)
Default:30
ROFF
Intermittent run OFF
time
Rang:0
–
600(Min)
Default:0
RONE
Intermittent intial
run time
Range:30-600(Min)
Default:90
UNIT
Temperture unit
Rang:
℃
-
℉
Default:
℃
AUTO
Timing start/stop
Rang
;
AUTO-OFF
Default:OFF
WEEK
Current Time
(hr,min)
FDLY
Blower delay
Rang:30-360S
Default:180S
LOCK
SV setting lock
Rang: YES
–
NO
Default:NO
PRO
Communiation
protocol
Rang:
MODBUS-RTU
ID
Communiation
ID Rang:1-99
Default:1
BAUD
Rang:4.8K 9.6K
19.2K
Default:9.6K
PAR
Parity bit
Rang:NONE
,
Odd
,
Even
Default:Odd
Data
Data length
Rang:8bit
Default: 8bit
Stop
Stop bit
Rang: 1bit
,
2bit
Default: 1bit
M+
△
+3S
SV
Rang:0-200
℃
Default:90
℃
100C
M+2S
M+5S
M+
▽
+3S
M+7S
△
/
▽
△
/
▽
△
/
▽
△
/
▽
△
/
▽
M
Exit
ALPH
Control coefficient
Rang:0~100
Preset value:50
BIAS
Temp. correction
Rang:-99~100
℃
Preset value:0
RJC
PC Temp.
Rang: 0~100
℃
temp.read only
AT
Self-tuning
Rang: YES
–
NO
Default:NO
M stands for
:
Menu key
△
/
▽
stands for
:
Up/Down key
4.1.8 Operation Flow