Shini SHD-E Manual Download Page 1

 

 

 

 

 

 

SHD-E 

Standard

 Hopper Dryer 

 

 

 

 

 

 

 

 

Date

Jul., 2022 

Version

Ver. C 

 

Summary of Contents for SHD-E

Page 1: ...SHD E Standard Hopper Dryer Date Jul 2022 Version Ver C...

Page 2: ......

Page 3: ...14 2 2 4 Blower Inlet Filter 14 2 2 5 Hopper Magnet 14 2 2 6 European Suction Box Shut off Suction Box 15 2 2 7 N Type Floor Stand 15 3 Installation and Debugging 17 3 1 Direct Installation 17 3 2 Pow...

Page 4: ...Table 13 Table 2 2 Configuration Table 13 Table 2 3 Configuration Table 14 Table 2 4 Configuration Table 14 Table 4 1 PID Setting Parameter 24 Table 4 2 Communication Setting Parameter 25 Table 4 3 Er...

Page 5: ...5 29 Picture 3 7 HAR Hot air recycler 21 Picture 4 1 Control Panel 22...

Page 6: ...6 29 1 General Description Please read through this operation manual before using the machine to prevent damages of the machine or personal injuries Picture 1 1 SHD 50E...

Page 7: ...by lead sheets and other models are equipped with temperature protector to prevent heater pipe from damaging by blower fault Overheat tripping can automatically cut off power when drying temperature...

Page 8: ...ny modifications of the machine must be approved by SHINI in order to avoid personal injury and damage to machine We shall not be liable for any damage caused by unauthorized change of the machine Our...

Page 9: ...20 SHD 150E 150 150 150 115 60 27 22 15 45 52 75 30 90 SHD 100E 100 100 100 80 40 20 16 10 30 35 50 20 60 SHD 75E 75 75 75 57 30 13 11 7 22 26 37 15 45 SHD 50E 50 50 50 38 20 10 8 5 12 17 25 10 30 SHD...

Page 10: ...switch are suitable and reliable When the machine is under care or maintenance turn off both power switch and automatic operation switch 1 2 1 Safety Signs and Labels Danger High presscure It is atta...

Page 11: ...from Shini including employees and agents Shini is exempted from liability for any costs fees claims and losses caused by reasons below 1 Any careless or man made installations operation and maintenan...

Page 12: ...n away by hot air thus to gain a satisfied drying effect Air blown out of blower via pipe heater became high temperature drying air after being heated Through shade separator and screen protector hot...

Page 13: ...Configuration Table Model Filtering Barrel Dia mm Inlet Air Pipe Dia inch Flange of Air Outlet inch Applied to HAR 12 157 2 SHD 12E HAR 25EB 157 2 5 SHD 25E HAR 50 177 3 SHD 50E 75E HAR 100EB 219 3 SH...

Page 14: ...Table Model Filtering Barrel Dia mm Overall height mm Applied to AIF 12 157 195 SHD 12E AIF 25EB 157 195 SHD 25E AIF 50 177 201 SHD 50E 75E AIF 100EB 219 191 SHD 100E 150E AIF 200EB 249 268 SHD 200E...

Page 15: ...s for single tube suction box and D stands for double tubes suction box 5 It must use with the floor stand 2 2 7 N Type Floor Stand Model Applied to Dimension H W D mm A B C mm FSN 50 SHD 12E 75E 600...

Page 16: ...16 29 the SHD E series...

Page 17: ...ce around the machine Please keep at least 2m distance between the device and the inflammable goods 3 This series of models only could be applied in working environment with good ventilation 3 1 Direc...

Page 18: ...L3 to the live wires and the earth PE to the ground Power supply requirements Main power voltage 5 Main power frequency 2 Please refer to the circuit diagram of each model for specific power access sp...

Page 19: ...workshop s environment Option with air exhaust filter ADC can filter the exhausted air from the dryer ADC can reach filter efficiency of 99 ADC is installed on air exhaust elbow of the dryer Point it...

Page 20: ...on of European suction box and shut off suction box is simple Install them at bottom of the hopper point to the holes and tighten up the screws Picture 3 5 Shut off suction box 3 4 3 Blower Inlet Filt...

Page 21: ...e AIF at blower inlet port point to the holes and tighten up the screws 3 4 4 Hot Air Recycler Installation Based on AIF blower inlet filter using a hear resistance pipe to connect the hopper exhausti...

Page 22: ...Temperature Setting 1 The setup number will flicker after pressing Setting key add or decrease temperature by pressing Up or Down key 2 Press Setting key again to confirm the input value 4 1 3 Temper...

Page 23: ...ey the set value flickers then press Up or Down key to add or decrease the value 3 Press Setting key to confirm the input value 4 Press Up key again and again it displays I integral time and D differe...

Page 24: ...to set OFF1 Mon off time OFF2 Tues off time OFF3 Wed off time OFF4 Thur off time OFF 5 Fri off time OFF6 Sat off time OFF7 Sun off time 2 Hold Menu for about 7S press Up or Down key to set ON1 Mon st...

Page 25: ...s Baud and PAR settings as below 7 Repeat step 3 and step 4 then confirm the related input parameters 8 Press Menu key to return operation menu Table 4 2 Communication Setting Parameter Communication...

Page 26: ...ng 30 600 Min Default 30 ROFF Intermittent run OFF time Rang 0 600 Min Default 0 RONE Intermittent intial run time Range 30 600 Min Default 90 UNIT Temperture unit Rang Default AUTO Timing start stop...

Page 27: ...le 4 3 Error Code Description Wrong Codes Remark bR Thermocouple break oH Overheat REV Temperature sensor reversely connected oL Overload bAT Battery error EGO EGO Over temp xATx Auto turning error LT...

Page 28: ...e blower regularly especially the air inlet path to remove the dust on surface 2 Eliminate the blower s dirt regularly to avoid the blower damage Note No need for regular inspection because all the el...

Page 29: ...lower runs while 1 Lead sheet of heater pipe melted 2 Magnetic switch fault 3 Heater fault 4 Controller fault 5 Thermocouple fault 1 Check and change 2 Check and change 3 Check and change 4 Check and...