ShinewayTech PPM-50 User Manual Download Page 8

PPM-50  PON  Power  Meter  User’s  Manual 

 

Shineway Technologies, Inc.                    

- 2 -

 

 

the shell of the instrument. 

 

Please  use  the  original  hard  packing  box.  If  use  other  packing  material,  please 

ensure at least 3 cm soft material around the instrument. 

 

Be sure to correctly fill out and return the warranty registration card, which should 

include the following information: company name, postal address, contact, phone 

number, email address and problem description. 

 

Be sure to seal the packing box with exclusive tape. 

 

Be  sure  to  ship  to  your  representative  or  the  agent  of  the  Company  in  a  reliable 

way. 

1.3 Introduction and Features 

ShinewayTech

   

PPM-30  is specially designed for  FTTx/PON test of next-generation 

optical network which features handheld, intelligent and high performance. 

 

Features 

 

The first PON Power Meter with TFT color screen 

 

Easy operation: Connect and get result 

 

Simultaneous Triple-play PON signals measurement: 
1310/1490/1550nm (Voice/Data/Video) 

 

 

Pass-through test: Applicable anywhere on PON 

 

Burst mode 1310nm upstream signal detection 

 

Pass/Warning/Fail assessment 

 

No PC software, User-defined Threshold Sets 

 

Internal Clock 

 

Fiber S/N Editable, easy to scan and save result 

 

 

Summary of Contents for PPM-50

Page 1: ...PPM 50 PON Power Meter User s Manual Shineway Technologies Inc...

Page 2: ...aser device user should always avoid direct eye exposure to the laser output Using microscope or magnifier to observe the laser output should also be avoided laser beam may converge on the retina and...

Page 3: ...tly into the optical output port when the instrument is working Always replace protective dust cap on the detector port when the instrument is not in use Always avoid looking directly at unconnected e...

Page 4: ...ration 4 2 2 3 Indicator 5 2 3 USE OF BATTERY 5 2 4 CONNECTOR CLEANING 5 3 OPERATION 7 3 1 POWER ON 7 3 2 FUNCTIONAL SETTING INTERFACE 7 3 2 1 Unit Switch 8 3 2 2 Threshold Switch 8 3 2 3 Threshold Se...

Page 5: ...PPM 50 PON Power Meter User s Manual Shineway Technologies Inc v 5 3 WARRANTY REGISTRATION 16 5 4 RETURNING INSTRUMENTS 16 5 5 CONTACT CUSTOMER SERVICE 17...

Page 6: ...Manual Shineway Technologies Inc vi Figure Contents FIG 3 1 7 FIG 3 2 7 FIG 3 3 8 FIG 3 5 9 FIG 3 6 9 FIG 3 7 9 FIG 3 8 10 FIG 3 9 10 FIG 3 10 11 FIG 3 11 11 FIG 3 12 12 FIG 3 13 12 FIG 3 14 13 FIG 3...

Page 7: ...anual For detailed information please refer to the packing list Upon receiving the instrument please check for any obvious signs of physical damage that may have occurred during shipment Report any da...

Page 8: ...ive tape Be sure to ship to your representative or the agent of the Company in a reliable way 1 3 Introduction and Features ShinewayTech PPM 30 is specially designed for FTTx PON test of next generati...

Page 9: ...hand held PON Power Meter Specific operations of each type are elaborated in Specific Functions and Operations chapter 3 of this manual Please read this manual carefully for optimal operation Should y...

Page 10: ...work with external power adaptor 5V DC 750mA 2 2 2 Keypad Operation Power on off Toggle between output wavelengths Toggle setting modes Adjust reference value in Setting interface Toggle setting mode...

Page 11: ...e 2 4 Connector Cleaning Please follow the instructions below when cleaning Turn off the instrument before cleaning Non compliant operation may result in hazardous radiation exposure Turn off laser so...

Page 12: ...PPM 50 PON Power Meter User s Manual Shineway Technologies Inc 6 Extra optical power attenuation Received optical power is beyond normal range...

Page 13: ...The default interface when power on see Figure 3 2 Reference Meas Save Save Option 1310nm 20 00 1490nm 13 00 1550nm 8 00 dBm FAIL dBm WRNG dBm PASS ONU OLT VIDEO OLT_name_XXXXXX ONT_name_XXXXXX 2011...

Page 14: ...s to exit functional setting interface 3 2 2 Threshold Switch Under functional setting interface press and to toggle to Threshold On Off see Figure 3 4 Threshold Select Thres_name1 Curr Thres Setting...

Page 15: ...en press and to select item see Figure3 6 Thres_name1 Curr Thres Setting Threshold On Off Zero System Setting 2011 09 15 17 41 5 Unit Select dBm Threshold Select Thres_name1 Threshold Select Thres_nam...

Page 16: ...select Save to save the adjustment The same method can be used to rename and edit the Threshold Name 3 2 5 Zero Under functional setting interface press and to toggle to Zero see Figure 3 9 Threshold...

Page 17: ...ect dBm Thres_name1 System Setting Fig 3 10 In Figure 3 10 press to enter system setting see Figure 3 11 Time Setting Brightness Auto Off Lang 15 19 50 English Date Setting 2011 09 16 2011 09 15 17 41...

Page 18: ...nized as USB device when the device is connected to the PC The PC can directly get data results through the USB device 3 2 8 Device Info Under functional setting interface press and to toggle to Devic...

Page 19: ...lt value as reference value or press to select reference value 3 4 Measurement and Save Press and to Meas Save interface see Figure3 15 Reference Meas Save Save Option 1310nm 20 00 1490nm 13 00 1550nm...

Page 20: ...on enable to choose whether convert file format to CSV file format If select converted to CSV file format the file can read by EXCEL 3 6 Recall Press and to select Recall interface see Figure 3 17 Mea...

Page 21: ...ibration 4 1 Cleaning of the connectors Keep the cleanness of connectors and dust caps The detector needs to be cleaned timely 4 2 Calibration Requirement Calibration of PPM 50 is recommended every th...

Page 22: ...ent The Provider reserves the right to make changes to any of its products at any time without having to replace or change previously purchased units 5 3 Warranty Registration A warranty registration...

Page 23: ...er Service Please check our web site www shinewaytech com for updates to this manual and additional application information If you need technical or sales support please contact local Shineway Technol...

Reviews: