29
No AC output
1. Circuit breaker is to
『
OFF
』
2. Output selector switch is to
『
ECO
』
1. Turn to
『
ON
』
2. Turn to
『
SINGLE
』
or
『
DUAL
』
AC Output is Weak
1. The power consumption of the load
exceeds the rated output
2. Dual Use
1. Adjust according to
『
OUTPUT
LIMITATION
』
2. Stop welding
Slow-Down does not activate
1. Short circuit of welding cable
2. The power consumption of the load
is 0.5A or below
1. Repair the short circuit
2. Turn the Slow-Down switch to
『
OFF
』
Engine does not stop
1. Stop Solenoid disorder
1.Turn the fuel lever to
『
CLOSE
』
to stop and repair
Black and white smoke exhaust
from muffler successively
1. Overloaded use
1. Keep the duty cycle
2. Adjust according to
『
OUTPUT
LIMITATION
』
Summary of Contents for DGW311DM
Page 31: ...30 14 Engine Wiring Diagram DGW311DM DGW311L...
Page 32: ...31 220V 60Hz 15 Generator Wiring Diagram...
Page 33: ...32 DGW311L W 220B 220V 60Hz...
Page 34: ...33 DGW311L W 380A 380V 50Hz...
Page 35: ...34 DGW311L W 400A 400V 50Hz...
Page 36: ...35 DGW311L W 415A 415V 50Hz...
Page 37: ...Head Office Telephone 81 82 849 2220 FAX 81 82 849 2481 71902 94012...