10-3 After Repair
After malfunction was repaired, eliminate the malfunction from “current” record in following steps.
1) Turn the starter switch to “RUN”.
2) Start the engine and run for few minutes.
3) Turn and remain the starter switch to “STOP” position for 30 sec. at least.
4) Turn the starter switch to “RUN”.
10-4 Elimination of “Past” Malfunction
“Past” malfunction has recorded in the ECM (Engine Control Module) unless it has deleted.
Follow the step below when the past “malfunction” record from the ECM should eliminate.
1) Turn the starter switch to “RUN”.
2) Press and hold the “memory clear button”.
3) Connect the 1-pin connector (green/blue) with a negative post (-) from the battery for 3 sec. at
least while holding the “memory clear button”.
“Monitor Lamp” Flashing – when the monitor lamp will blink 3 times and twice shorter, it shows the engine code
“32”, for example.
Flashing Pattern of “Monitor Lamp” – for the engine code “225”;
Monitor
Lamp: ON
Monitor
Lamp: OFF
t1= approx.0.3 sec.
t2= approx.
0.6
sec.
t3= approx.1.2 sec.
t4= approx.2.4 sec.