14
(1) Exciting Amperage
Amperage fluctuates based upon the winding temperature. Following is for reference only.
Frequency/Rated Output
Load
Exciting Amperage
(Measured)
3-Phase
60Hz: 20 kW
No load
0.34A
Full load( power factor=1.0)
0.60A
(2) Resistance Value
Nominal resistance of the winding is tolerated
within
± 10% at 20
℃
of the ambient temperature.
The resistance must be measured by low resistance tester. It can not be measured by
multi-purpose tester due to index error.
Measurement value (Ω
)
Main Stator
Exciter Stator
Rotor
1
2
3
4
5
Armature
Exciter Winding
J
-
K
Exciter Field
Armature
Between
1-2 (L1)
2-3 (L2)
3-1 (L3)
A – B
B – C
C – A
-
-
-
#1
0.65
Ω
1.35
Ω
23.2
Ω
13.4
Ω
2.7
Ω
#2
0.16
Ω
1.
Armature (Main Stator
)
#1
Measure the resistance among the U-W by the low ohm tester. Each shall be 0.16 x 4=0.65Ω.
(B)
(W)
(R)
(G)
(Y)
(Br)
(L)
(Or)
(Gr)
(Vi)
Black
White
Red
Green Yellow Brown Blue Orange
Gray Violet
1-2 (L1)
2-3 (L2)
3-1 (L3)
when the voltage selector switch is
set at 480V
: