background image

 

RB-473-B02M 

28 

6.8. Contact lens 

6.8.1.  Preparation 

(1)

 

To  measure  a  hard  contact  lens,  select  'H.Cont'  in 

the  Menu  screen.  For  a  soft  contact  lens,  select 

'S.Cont'.   

 

 

 

 

 

 

 

 

(2)

 

Change  the  lens  stand  to  the  contact  lens  stand  included  in  the  accessories  and  measure  the  contact 

lens. 

Standard nosepiece

Contact lens stand

 

 

6.8.2.  How to measure 

(1)

 

Set the contact lens in the contact lens stand as shown below. 

(2)

 

Remove the standard lens stand and mount the contact lens stand. 

(3)

 

Lower the lens holder and hold the contact lens stand. 

(4)

 

Move  the  contact  lens  stand  vertically  and  horizontally  to  bring  the  lens's  center  to  the  center  of  the 

instrument. 

 

Contact lens

stand

Contact lens

             

Contact lens stand

Contact lens

 

 

 

 

S/R/L 

 

R/L 

 

Off 

 

Off 

 

X-Y 

 

P-B 

 

Off 

 

On 

 

Off 

 

On 

 

0.25 

 

0.12 

 

0.01 

 

Normal 

 

H Cont 

 

S C ont 

 

On 

 

Step 

 

Lens Switch 

 

Lens 

 

Prog Auto 

 

Prism 

 

Graph Print 

 

Prog. Graph 

 

ADD Measure 

 

Set up 

 

1/2

 

Off 

 

On 

 

Auto Memory 

 

F/N.AT 

 

N.AT 

 

Manual 

 

Summary of Contents for SLM-5000

Page 1: ...RB 473 B02M Operations Manual Important Read this manual thoroughly before use Keep this manual on hand at all times Auto Lensmeter SLM 5000...

Page 2: ...NOTE 1 The information contained in this manual is subject to change without notice 2 While reasonable efforts have been made in the preparation of this document to ensure its accuracy you should con...

Page 3: ...ny liquid gets on the instrument or when any foreign matters gets inside the instrument unplug the power cord immediately and contact your local distributor In case of occurrence of abnormality noise...

Page 4: ...d clean without any dust or oil on it The dirty terminal may cause malfunction or fire When the power cord becomes hot after used check for the dirt at the terminal part If you find no dirt replace th...

Page 5: ...t of marking pen 16 5 4 Printer 17 5 4 1 How to operate 17 5 4 2 Type of print out 17 5 4 3 Setting and replacement of printer paper 18 6 Measurement 19 6 1 Check before Measurement 19 6 2 Single Lens...

Page 6: ...Parts Identification 1 1 Overview Printer Power switch Power inlet RS 232C terminal Rating nameplate Color LCD monitor Operation switches Indicator Marking lever Lens plate Lens stand Lens holder Mem...

Page 7: ...heck the followings are all packed without any damages Contact your distributor if any accessories are missing or damaged Power cord Contact lens stand Rolls of printer paper Printer shaft Dustproof c...

Page 8: ...re range for use 10 C 40 C Temperature range for storage 10 C 60 C Humidity range for use storage 70 HR no dew condensation allowed 4 Keep away from inflammable or explosive gases as well as storage a...

Page 9: ...ith care at all times making sure not to accidentally drop it 5 If the instrument is not to be used for any length of time remove the power cord from the outlet 6 When not in use the instrument should...

Page 10: ...the addition is measured determines the far point for auto measurement of the progressive lens For the manual measurement determines the measurement positions and values for the far and near points ME...

Page 11: ...r near point after the progressive lens is measured Off not printed On printed Off Prism Selects whether to display prism values and which unit is used if displayed Off not displayed X Y X Y display P...

Page 12: ...itch to call up Screen 2 Using and move the cursor to the letter or symbol you wish to change Then release Memory Add switch to return to the Screen 1 Select the letter or symbol you wish to change an...

Page 13: ...te Transfer rate 38400 NB Bit Character length data bit 8 fixed Parity Parity check None fixed Stop Bit Stop bit 1 fixed Signal names and connection Connect each connector of the serial interface as s...

Page 14: ...M D Y year date month Date change of the date Move the cursor to the item you wish to change with While Memory Add switch is pressed Screen 2 will be displayed Make changes using Time change of the ti...

Page 15: ...ush the PUSH mark on the lens plate to unlock it The lens plate will come out To lock the lens plate push it again 2 The lens plate comes out until it touches the lens when pushed Place the frame lens...

Page 16: ...nger slowly after finishing marking on a lens 4 Marking lever returns to the initial position Observe the following otherwise you may damage the pen tip Do not push the marking pen too hard when marki...

Page 17: ...en as shown below Then insert the pen back to the initial position 3 Holding the marking pen fix it with the screw note A central marking pen is black and is shorter than pens on both sides Use the ma...

Page 18: ...O 0 00 D 3 50 SHIN NIPPON SLM 5000 2002 03 25 10 25 The unit of the prism value depends on the setting NAME Print out sample when a single focal lens is measured ADD value is printed out when mutifoc...

Page 19: ...sert the printer shaft into the roll of the paper and set it in the printer unit Printer shaft Printer paper 3 Hook the tabs of the cover to the tabs of the unit Take out the end of the paper a little...

Page 20: ...5 4 3 Setting and replacement of Printer paper Check that no lenses are placed on the lens stand Turn the power on The screen below will appear in a few seconds Always make sure that the cable is gro...

Page 21: ...nsmeter and the cross cursor that of the lens 3 Move the lens until the cross cursor and the alignment matches When they match the message Marking OK will appear to indicate that marking is ready to b...

Page 22: ...y press Press to print out the values Great care should be taken not to give strong impact to the lens when lowering the lens holder Confirm that the lens holder is locked at the top when pushing it u...

Page 23: ...lues stored in memory are shown in red After stored in the memory the values displayed on the screen will be fixed 5 Press to switch to the lens for a left eye At this time the measurement result for...

Page 24: ...point in memory After the measurement values are stored ADD values will become red For a trifocal lens Press Memory Add switch again to display Ad2 on the screen Bring the second near point into the c...

Page 25: ...placed on the lens stand automatic judgment may also fail In such a case try to move the lens slowly back and forth or to the right or left When ADD value is small under 1D the lens in the frames is...

Page 26: ...s green Then the measurement value of the far point is stored in memory 3 Near point measurement Move the lens slowly toward you according to the arrow as shown in the screen 4 so that the alignment c...

Page 27: ...o so In such a case measure manually based on the graphs of Add value and assessment To measure the far point manually carry out alignment a ccording to the shape of the alignment cursor as you do for...

Page 28: ...asurement value is stored automatically in memory when the alignment mark and the cross cursor overlap as shown on the left 6 7 Power saving function Power saving function is activated when no switche...

Page 29: ...in the contact lens stand as shown below 2 Remove the standard lens stand and mount the contact lens stand 3 Lower the lens holder and hold the contact lens stand 4 Move the contact lens stand vertica...

Page 30: ...e target so that the AXIS mark matches the value in the prescription 2 To be more precise align according to the AXIS value measured Marking on the cylindrical axis 1 Match the target so that the AXIS...

Page 31: ...displayed on the screen accord with those of the prescription P Prism value B Base direction Prescription expressed in mm 1 Select On from Prism mm in the Menu screen 2 Move the lens so that the prism...

Page 32: ...lens stand when the power is turned on or if the lens under the lens stand is dirty Remove the lens if it is on the lens stand If the lens under the lens stand is dirty gently wipe it with a soft clo...

Page 33: ...ens Soft contact lens A special accessory is required Power supply 100 240V 50 60Hz Printer Thermal printer paper width 58mm Monitor Color LCD monitor 5 7 inches Dimension weight 200 W x260 D x443 H a...

Page 34: ...ve Distributor Manufacturer RyuSyo Industrial Co Ltd Kagawa Factory 958 IKEUCHI KOUNAN CHO TAKAMATSU KAGAWA 761 1494 JAPAN AJINOMOTO TRADING INC SHIN NIPPON Medical Ophthalmic Instruments Dept EAST WI...

Reviews: