3. KEY FUNCTIONS

All keys are capacitive touch.

ON/OFF: Push for 2 seconds to power On or Off

During Measurement: Print the current force value or   

store data, depending on the key setting. (See 4.5.8 for  

key 

setting)

In Menus: Back or quit.

During Measurement: Enter the menus.
In Menus: Select or Enter

During Measurement: Track mode, tares weight of 
attachment. In Peak & Auto Peak modes, resets the 
peak 

value.

In Menus: Moves selection up or increases the value.

During Measurement: Changes the measure mode from  
Track, Peak, Auto Peak, First Peak
In Menus: Moves selection down or decreases the 
value.

4. ADVANCED MENU OPTIONS

4.1 Menu Structure

From the home screen, touch “MENU” to enter the main menu. 
(Figure 4-1)

Figure 4-1a  

        Figure 4-1b

4.2 Measurement

The Measurement menu contains six selectable items: Unit, 
Group, Tolerance, Peak Time and Alarm. (Figure 4-2)

Figure 4-2a 

    Figure 4-2b

      4.2.1 Unit

The measuring unit can be selected under this menu. Differ-
ent range models may have different unit selection capabili-
ties. Touch “ZERO” or “MENU” keys to shift to the next selec-
tion. Press “LOG” to cancel or touch “MENU” to confirm and 
exit. (Figure 4-2c)

Figure 4-2c

4.2.2 Group

When several test samples need to be measured, the sam-
ples can be coded into groups. The range is 01-99. When set 
to “00”, become, “01” automatically. Press “ZERO” to adjust 
the value, touch “MODE” to shift to the next position. Touch       
“LOG” to cancel; press “MENU” to confirm and exit. (Figure 
4-2d)

Figure 4-2d

4.2.3 Tolerance

In the Tolerance menu, program high and low limit values to 
enable ok/ov testing. The lower limit value cannot be greater 
than the upper limit value, and neither limit value can be great-
er than 110% of the rated capacity. Press “ZERO” to adjust the 
value, touch “MODE” to shift to the next position. Press “LOG” 
to cancel; touch “MENU” to confirm and exit. (Figure 4-2e)

NOTE:

 Alarm must be set to on for tolerance values to be ac-

tive.

Figure 

4-2e

Menu

Measurement

Unit

Group

Tolerance

Test Mode

Peak Time

Alarm

Memory

Storage Mode

Browse All

Browse Selected

Delete Selected

Delete All

Printing

Print Recent

Print Selected

Print All

System

Display Mode

Display Direction

Auto Power Off

Backlight

Key Tone

Date/Time

Password

Key Setting

RS-232 Baud Rate

Default Setting

Language

Calibration

Information

3

www.

.com

[email protected]

1.800.561.8187

Summary of Contents for FG-7000L Series

Page 1: ...O INSTRUMENTS Operators should wear protection such as a mask and gloves in case pieces or components break away from the unit under test Whether the unit is ON or OFF DO NOT exceed the capacity of the sensor NEVER exceed 150 of the rated capacity for S beam or 120 for ring type or the load cell will be damaged At 110 of the rated capacity the display will flash a warning When mounting FG 7000L Se...

Page 2: ... 10 Resolution 1 0 1 0 5 0 01 S 20 20kN Capacity 2000 4500 20 Resolution 0 5 1 0 005 Ring Type for Compression N kgf lbf kN klbf tf R 10 10kN Capacity 10000 1000 2250 10 Resolution 0 1 0 1 0 5 0 01 R 20 20kN Capacity 2000 4500 20 Resolution 0 5 1 0 005 R 50 50kN Capacity 5000 50 11 5 Resolution 1 0 01 0 001 0 001 R 100 100kN Capacity 100 22 10 Resolution 0 01 0 005 0 001 R 200 200kN Capacity 200 4...

Page 3: ... selec tion Press LOG to cancel or touch MENU to confirm and exit Figure 4 2c Figure 4 2c 4 2 2 Group When several test samples need to be measured the sam ples can be coded into groups The range is 01 99 When set to 00 become 01 automatically Press ZERO to adjust the value touch MODE to shift to the next position Touch LOG to cancel press MENU to confirm and exit Figure 4 2d Figure 4 2d 4 2 3 Tol...

Page 4: ...LOG to cancel touch MENU to confirm and exit Figure 4 3b Single At the home screen pressing the LOG stores the cur rent displayed value If the default settings key is for storage See 4 5 8 key setting Series Continuous data logging will only operate while in the Auto Peak measuring mode When the peak time has expired unit stores the current displayed peak value and then resets the peak value on th...

Page 5: ...menu several parameters may be set per Fig ure 4 5a 4 5b Figure 4 5a Figure 4 5b 4 5 1 Display Mode Two display modes may be selected Digital and Graphic Fig ure 4 5c Figure 4 5c 4 5 2 Display Direction Select the mode of the LCD display Automatic Obverse and Reverse Touch ZERO or MODE keys to shift to the next position Press LOG to cancel Push MENU to confirm and exit Figure 4 5d Figure 4 5d 4 5 ...

Page 6: ...perate improperly you can restore it to the factory default settings Carefully use this function Figure 4 5l Figure 4 5l 4 6 Language Select between English German and Chinese Figure 4 6a Figure 4 6a 4 7 Calibration Users can field calibrate the gauge First enter the system pass word Default is 123 by pressing the ZERO and MODE keys Then press MENU to confirm Figure 4 7a Figure 4 7a 1Calibration P...

Page 7: ...dard protocol Figure 6 1a The USB Port can be connected to a charger with the USB cable for charging the internal Ni MH battery and can be connected to a computer for uploading the measured values Connect the gauge and the computer with the USB cable then open the computer software Upload the values Please refer to the software manual for addi tional information 6 2 Port Pin Assignments Figure 6 1...

Page 8: ...Communications Port See Figure 6 1a 7 3 Dimensions S Beam Ring Type Capacity Dimensions W H B M 1kN 51 76 2 19 M12X1 75 2kN 5kN 10kN 25 4 20kN 76 2 108 M18X1 5 Capacity Dimensions mm D d L H SR DI M 10kN 32 8 14 16 16 24 5 3 M5 20kN 38 11 30 50kN 82 22 32 44 50 68 4 M8 100kN 200kN 100 28 36 48 120 80 S Beam Load Cell Ring Load Cell www com information itm com 1 800 561 8187 ...

Reviews: