Shimpo Instruments FG-7000L Series Operation Manual Download Page 2

1. LCD SCREEN STANDARD VIEW

Test Mode Icons:

2. Battery icon: Battery level or charging status. Flashes when

gauge needs to be recharged.

3. OK/OV Indicator:

4. Force Icons: Indicates force direction.

5. Current measured value

6. Analog bar: Indicates current position within full scale. When

the bar enters the area enclosed by the dotted line, this

signifies the full scale capacity is exceeded by an overload

condition.

7. Storage icon: Indicates data is being saved.

8. System time

9. Units Indicator: Selected engineering unit.

10. Load Cell Capacity Icon:

2

S-Beam for Compression or Tension

N

kgf

lbf

kN

S-1

1kN

Capacity

1000

100

220

-

Resolution

0.1

0.01

0.05

-

S-2

2kN

Capacity

2000

200

450

-

Resolution

0.5

0.05

0.1

-

S-5

5kN

Capacity

5000

500

1100

-

Resolution

1

0.1

0.1

-

S-10

10kN

Capacity

10000

1000

2250

10

Resolution

1

0.1

0.5

0.01

S-20

20kN

Capacity

-

2000

4500

20

Resolution

-

0.5

1

0.005

Ring Type for Compression

N

kgf

lbf

kN

klbf

tf

R-10

10kN

Capacity

10000

1000

2250

10

-

-

Resolution

0.1

0.1

0.5

0.01

-

-

R-20

20kN

Capacity

-

2000

4500

20

-

-

Resolution

-

0.5

1

0.005

-

-

R-50

50kN

Capacity

-

5000

-

50

11

5

Resolution

-

1

-

0.01

0.001

0.001

R-100

100kN

Capacity

-

-

-

100

22

10

Resolution

-

-

-

0.01

0.005

0.001

R-200

200kN

Capacity

-

-

-

200

44

20

Resolution

-

-

-

0.05

0.01

0.005

1

2

3

4

9

8

7

6

5

10

Under Lower Limit

Between Low Limit & Upper Limit

Over Upper Limit

Tension

Compression

Track: Real Time, live measuring mode

Peak: Reading will not change until a higher value is mea-
sured
AutoPeak: When Peak Time is up, resets peak value automat-
ically
First Peak: Captures First Peak after drop ratio decrease has 
been detected. Drop Ratio set in menus.

If no load cell is connected, this symbol appears & blinks

2. LOAD CELL CAPACITY & RESOLUTION TABLES

Digital View

Graphic View

1

3

5

9

8

2

7

10

6

www.

.com

[email protected]

1.800.561.8187

Summary of Contents for FG-7000L Series

Page 1: ...O INSTRUMENTS Operators should wear protection such as a mask and gloves in case pieces or components break away from the unit under test Whether the unit is ON or OFF DO NOT exceed the capacity of the sensor NEVER exceed 150 of the rated capacity for S beam or 120 for ring type or the load cell will be damaged At 110 of the rated capacity the display will flash a warning When mounting FG 7000L Se...

Page 2: ... 10 Resolution 1 0 1 0 5 0 01 S 20 20kN Capacity 2000 4500 20 Resolution 0 5 1 0 005 Ring Type for Compression N kgf lbf kN klbf tf R 10 10kN Capacity 10000 1000 2250 10 Resolution 0 1 0 1 0 5 0 01 R 20 20kN Capacity 2000 4500 20 Resolution 0 5 1 0 005 R 50 50kN Capacity 5000 50 11 5 Resolution 1 0 01 0 001 0 001 R 100 100kN Capacity 100 22 10 Resolution 0 01 0 005 0 001 R 200 200kN Capacity 200 4...

Page 3: ... selec tion Press LOG to cancel or touch MENU to confirm and exit Figure 4 2c Figure 4 2c 4 2 2 Group When several test samples need to be measured the sam ples can be coded into groups The range is 01 99 When set to 00 become 01 automatically Press ZERO to adjust the value touch MODE to shift to the next position Touch LOG to cancel press MENU to confirm and exit Figure 4 2d Figure 4 2d 4 2 3 Tol...

Page 4: ...LOG to cancel touch MENU to confirm and exit Figure 4 3b Single At the home screen pressing the LOG stores the cur rent displayed value If the default settings key is for storage See 4 5 8 key setting Series Continuous data logging will only operate while in the Auto Peak measuring mode When the peak time has expired unit stores the current displayed peak value and then resets the peak value on th...

Page 5: ...menu several parameters may be set per Fig ure 4 5a 4 5b Figure 4 5a Figure 4 5b 4 5 1 Display Mode Two display modes may be selected Digital and Graphic Fig ure 4 5c Figure 4 5c 4 5 2 Display Direction Select the mode of the LCD display Automatic Obverse and Reverse Touch ZERO or MODE keys to shift to the next position Press LOG to cancel Push MENU to confirm and exit Figure 4 5d Figure 4 5d 4 5 ...

Page 6: ...perate improperly you can restore it to the factory default settings Carefully use this function Figure 4 5l Figure 4 5l 4 6 Language Select between English German and Chinese Figure 4 6a Figure 4 6a 4 7 Calibration Users can field calibrate the gauge First enter the system pass word Default is 123 by pressing the ZERO and MODE keys Then press MENU to confirm Figure 4 7a Figure 4 7a 1Calibration P...

Page 7: ...dard protocol Figure 6 1a The USB Port can be connected to a charger with the USB cable for charging the internal Ni MH battery and can be connected to a computer for uploading the measured values Connect the gauge and the computer with the USB cable then open the computer software Upload the values Please refer to the software manual for addi tional information 6 2 Port Pin Assignments Figure 6 1...

Page 8: ...Communications Port See Figure 6 1a 7 3 Dimensions S Beam Ring Type Capacity Dimensions W H B M 1kN 51 76 2 19 M12X1 75 2kN 5kN 10kN 25 4 20kN 76 2 108 M18X1 5 Capacity Dimensions mm D d L H SR DI M 10kN 32 8 14 16 16 24 5 3 M5 20kN 38 11 30 50kN 82 22 32 44 50 68 4 M8 100kN 200kN 100 28 36 48 120 80 S Beam Load Cell Ring Load Cell www com information itm com 1 800 561 8187 ...

Reviews: