Starting an Examination

It takes a short while for the system to start-up.

If the preparation of fluoroscopy image functions is completed before starting an 

examination, you can perform emergency fluoroscopy.

For a New Study (Emergency Patient)

You can set either from the main panel or the reference monitor.

This selection is only possible on the reference monitor.

When you obtain a study list, 

please connect the LAN cable 
to the back of the monitor cart.

• Temporary data information can be changed 

afterward in the [Today] tab or the [All] tab in the 
Study List window. 

• The patient information of images acquired in an  

emergency study can be changed later on by 
updating the patient information in the [Image List].

1

The patient ID and patient name are set 

automatically.

Press 

 (on the C-arm main panel) or

click 

 (on the reference monitor). 

Basic screen (Emergency case)

C-arm main panel

Reference monitor

1

If the [Study List] window is not displayed, 

click 

 .

2

Click the target study.

The study information is displayed in the 

lower part of the window.

3

Click 

 .

The study is registered and begun.

Study List

Study information

LAN cable

Memo

Memo

M516-E044

Summary of Contents for OPESCOPE ACTENO

Page 1: ...art C Memory Frame Memory Loop Memory Apply power only to the C arm Conducting Examinations 1 2 Starting an Examination Selecting the APR Conducting Examinations 2 3 Fluoroscopy Adjusting Image Changi...

Page 2: ...C arm cart s brake applied Operate the brake Are the monitor cart s brakes applied Operate the brake Visual aural inspection Is the operating noise normal Notify Is any error message displayed on the...

Page 3: ...wn 8 1 2 4 6 7 Power switch Take the power plug out of the outlet 5 Shut down the system from the reference monitor 3 2 Main panel 3 Front of the monitor cart Back of the monitor cart C arm M516 E044...

Page 4: ...ment C arm slide motion About the scales The zero on each scale is the C arm s home position fixed position Starting up and Shutting down the System Instruction Manual 3 6 Positioning Handle Handle Ha...

Page 5: ...he LAN cable to the back of the monitor cart Temporary data information can be changed afterward in the Today tab or the All tab in the Study List window The patient information of images acquired in...

Page 6: ...ic Screen APR Selection Screen Immediate Selecting the APR Immediate Select the APR 2 The basic screen is displayed and the parameters registered in the APR are loaded 1 The APR selection screen Immed...

Page 7: ...splayed at the top right of the LCD display Resets the image brightness setting to the default value Parallel compensating filter open close Parallel compensating filter rotation Octagonal collimator...

Page 8: ...the Dose Change the Pulse rate Changing the filter Auto Manual Switches the X ray adjustment mode The filter is changed each time is pressed Display Material Applications Filter 1 Cu0 1 mm The limbs...

Page 9: ...r foot from the foot switch during irradiation will end X ray irradiation partway through and stop radiography Depress the right foot switch 3 During X ray irradiation the radiography image is display...

Page 10: ...mators Beam hardening filter Image rotation and inversion I I field size Storing Calling Up Basic screen 1 Press Save You can save the currently displayed images If any condition is changed from the s...

Reviews: