4-4. Instruction for screen change and each screen

Mode 0 screen group

Basic screen
SV initial value: lower limit of 

mesuring range

Setting range: within measuring 

range

Upper row displays measured
value (PV) and lower row displays
and changes the set value (SV).
Refer to 5-1 for detail.

AT (auto tuning)
action control screen
Initial value: OFF
Setting range: OFF,ON
For "ON" selection, AT is executed
and for "OFF" selection, AT is
cancelled.
Refer to 5-2 for detail.

Higher limit alarm set screen
Initial value:

absolute value alarm higher
limit for the measuring range
Deviation alarm 2000 unit

Setting range:

absolute value alarm within
measuring range
Deviation alarm 0~2000 unit

Displays except the case with
alarm option and the alarm type of
the mode 2 screen is not specified.
Refer to 5-3 (1) for detail.

Lower limit alarm set screen
Initial value:

absolute value alarm lower
limit for the measuring range
Deviation alarm -1999unit

Setting range:

absolute value alarm within
measuring range
Deviation alarm -1999~0 unit

Displays in case with alarm option
and the alarm type of the mode 2
screen is higher limit and lower
limit.
Refer to 5-3 (2) for detail.

Heater break alarm value set screen
Initial value: OFF
Setting range: OFF, 0.1~50.0A
Displays in the case with heater
break alarm option and alarm type
of the mode 2 screen is higher limit
+ heater break.
Refer to 5-3 (3) for detail.

Use 

key to move select digit and data

registration, the selectable digit is
indicated by flashing point.

Upper row displays load current detected by CT.
(If the output is OFF, it shows 

)

NOTE: The heater break alarm can be added if the 

instrument has alarm option and the control 
output is the contact type or the SSR drive voltage 
type.

Heater break alarm

Set the alarm level at approx. 85% of the normal load current.

In case of large current variation, set larger value.
If multiple heaters are connected in parallel, set a larger value
to output alarm for single heater break.

If "OFF" is selected, no alarm output is obtained.

Selecting "OFF" during alarm output, the alarm output is
canceled.

For case when heater break function is not applicable to direct

current load, phase controlling current and three phase heater.

Connecting current transformer (CT)

One of the load line wires passes through the hole of the
custom CT.
Wire from the secondary side terminal of CT to the CT input
terminal of the instrument.

NOTE: Two types of the heater break CT of 30A and 50A are

available, the type selected upon ordering is shipped
with the product as an accessory. Note the maximum
current to be set is 50.0A for both types.

NOTE: If it is on auto tuning excution or key lock is set

on lock No.1,2 or 3, no selection can be
performed even if the digit point is flashing.

Digit 

and 

are not shown in case of no option Digits of  ,

and 

are not displayed.

• : Measuring range code select digit

Initial value: Multi05, voltage V81, Current 95 fixed.
Selecting two digits from "4-5. Measuring range code
table"

: Control output characteristic select digit

Initial value:

: Refer to 6-3.

: RA (heating characteristics)

: DA (cooling characteristics)

: Alarm type select digit

Initial value: 

Select from "4-6. Alarm type code table"

: Heater break alarm action mode select digit

Initial value: 

Select from

: Lock mode and 

: REAL mode.

Refer to 5-3 (3).

Input scaling screen
Initial value:
Lower limit value (top row)

0.0

Higher limit value (bottom row) 100.0
Position of decimal point

0.0

Setting range:
Lower limit value  -1999~9989 units
Higher limit value

-1989~9999 units

Span = Higher limit value - Lower limit
value
= 10~5000 counts
Position of decimal point:
No decimal point, 0.0, 0.00 and 0.000

Scaling is done for linear input (mV, V or mA).
The screen is only for monitoring and no setting is possible in
the case of sensor input.
Refer to Item 4-2 (6) for details.

NOTE: Screen flame on 4-4 is as follows:

Screens always shown during key
operation.

Screens shown during case with
option or selected option.

Screens shown or skipped depending
on control action mode.
(PID action or ON/OFF action)

Lock No.

OFF

1

2

3

Screen range locked

Unlock (all data change enabled)

Basic screen, Key lock for screens except AT action control screen

Key lock for screens except basic screen.

All key lock

To CT input terminal of
controller (no polarity)

Heater (load) wire

Direct call screen (screen No.0)
Initial value: 0
Setting range: 0~12

Set the screen No. to move the screen of the mode
screen group.
Refer to 4-2 (4) for detail.
The screen with no display condition is skipped.

Set value blas set screen (screen No.1)
Initial value: 0
Setting range: -1999~2000 unit

Displays in the case with set value bias option. The set
value is effective during shorted SB terminal, and is
added to or subtracted from the set value. The point of
the least digit of the lower row turns on while this
function is effective.

Proportional band set screen (screen No.2)
Initial value: 3.0%
Setting range: OFF, 0.1~999.9%

Not required in case of auto tuning. Refer to 6-2 (1)  
for proportional band. Select "OFF" to perform 
ON/OFF (two position) action.

Action hysteresis set screen (screen No.3)
Initial value: 3 or 0.3
Setting range: 1~999 unit

Set ON/OFF hysteresis on ON/OFF action.
Not displayed on PID action.

Integral time set screen (screen No.4)
Initial value: 120 seconds
Setting range: OFF, 1~6000 seconds

Not required for auto tuning.
Refer to 6-2 (2) for integral time.
Not shown on ON/OFF action.

Derivative time set screen (screen No.5)
Initial value: 30 seconds
Setting range: OFF, 1~3600 seconds

Refer to 6-2 (3) for derivative time.
Not shown on ON/OFF action.

Manual reset value setting screen (screen No.6)
Initial value: 0.0%
Setting range: -50.0~+50.0%
Offset is adjusted when I=OFF (P or PD action) is
selected.
This screen appears only when I=OFF has selected.
Manual Reset Value

In the PID operation, an offset is corrected
automatically by I,i.e, integral calculation. When it is
set at OFF, this correction is not made and output is
manually increased or decreased for correction. This
is called manual reset (MR).

Set value function set screen (screen No.7)
Initial value: 0.40
Setting range: OFF, 0.01~1.00

Used for suppressing overshooting and undershooting in
expert PID. For SF=1.00 minimize overshooting, for
SF=OFF, expert PID is unable to be normal PID action.
Not shown on ON/OFF action.

PV bias value set screen (screen No.8)
Initial value: 0 or 0.0
Setting range: -200~200 unit

Used for sensor input error compensation.
Controlling is performed with corrected value for bias
setting.

PV filter time set screen (screen No.9)
Initial value: 0 second
Setting range: 0~100 seconds

Used for the case of large input change and noise
overlapping to reduce the effect.

Key lock mode set screen (screen No.10)
Initial value: OFF
Setting range: OFF, 1,2,3

Lock the item not to be changed.
No data change is effective on the display screen locked.

Following table shows the lock No. and screen range
locked.

Summary of Contents for SR70 Series

Page 1: ...ties additional instructions are indicated by the following headings WARNING Exercise extreme caution as indicated This heading indicates hazardous conditions that could cause injury or death of perso...

Page 2: ...ge 23 The output terminal should be connected with a device which meets the requirements of IEC1010 A voltage current different from that of the input specification should not be added on the input te...

Page 3: ...resentative or our local office concerning any problems with the product accessories or related items 1 2 Caution for use 1 Avoid operating keys of the front panel with hard or sharp objects or motion...

Page 4: ...se and rotate the screwdriver while pushing up the lock lever behind the packing Once the instrument comes out by a few millimeters you can remove it by hand 2 4 External dimensions and panel cutout S...

Page 5: ...nal Recommendable noise filter TDK ZMB2203 13 Name of terminal and description Power terminal 100 240V AC 10 50 60Hz 11VA Protective conductor terminal Input terminal R T D A Thermocouple Voltage Curr...

Page 6: ...3 AH alarm output monitor LED red Turns on for higher limit alarm output ON 4 AL HB alarm output monitor LED red Turns on for lower alarm output ON or heater break alarm ON Key switches 1 parameter ke...

Page 7: ...econds on basic screen of the mode 0 screen group to change the screen into mode 2 screen Keep pressing key for five 5 seconds on the mode 2 screen to change screen into basic screen of the mode 0 scr...

Page 8: ...ssed the flashing decimal point in the rightmost digit moves from the top row bottom row top and bottom rows top row In case the lower limit value and the higher limit value are set to produce a diffe...

Page 9: ...action mode select digit Initial value Select from Lock mode and REAL mode Refer to 5 3 3 Input scaling screen Initial value Lower limit value top row 0 0 Higher limit value bottom row 100 0 Position...

Page 10: ...20 21 22 39 40 41 42 43 44 45 46 Measuring range F 0 3300 0 3100 0 3100 150 750 0 2200 0 1300 0 1100 300 400 0 2300 300 400 0 1100 300 1100 150 0 200 0 50 0 120 0 0 400 300 1100 150 0 200 0 50 0 120...

Page 11: ...in the following condition during AT execution Duration equal to or longer than 2 hours passed in the output level of 0 or 100 Power shutdown PV measured value is over the scale during AT execution 5...

Page 12: ...s selected Lower limit deviation value alarm is output for measured value to be less than set value alarm set value For lower limit deviation value alarm if set value alarm set value is less than the...

Page 13: ...ade for longer than three 3 minutes on each screen except heater break alarm value set screen the screen moves back to the basic screen of the mode 0 screen group auto return 6 2 PID Screen No 2 4 and...

Page 14: ...B and multiple break of A B B upon R T D input 2 Defect of heater break alarm CT CT input value is greater than 55A CT input value is less than 5A NOTE Message of heater break alarm is only displayed...

Page 15: ...C to the negative side of measuring range in case of T and U input though JIS Pt100 Jpt100 3 wire type Approx 0 25mA 5 max wire The 3 lead wires should have same resistance 0 10 10 50 0 100mV DC or 0...

Page 16: ...ge detected by externally attached CT Alarm output On upon detection of heater break while control output is On Off 0 1 50 0A Alarm action stops when Off is set 0 1A 0 0 55 0A 5 FS when sine wave is 5...

Reviews: