Application parameter group 10
PARAMETER DESCRIPTION 147
Acceleration and deceleration interrupt waiting function(10-18(P.229)=“2”)
When 10-18 (P.229) = "2", enable acceleration and deceleration interrupt waiting function. When accelerating to
the frequency set in 10-19 (P.230), wait for the time set in 10-20 (P.231)
before accelerating to the target; when
decelerating to the frequency set in 10-21 (P.232), wait for the time set in 10-22 (P.233) before decelerating to the
target.
As shown in the following diagram:
Time
Start
Stop
Hz
10-20
(
P.231
)
10-19
(
P.230
)
T
ar
ge
t
fr
eq
ue
nc
y
10-22
(
P.233
)
10-21
(
P.232
)
Acceleration
deceleration
stop function
T
hr
ee
-w
ire
co
nt
ro
l 1
Note: After setting backlash compensation, only the interruption time in acceleration and deceleration time will become
longer.
5.10.10 Triangular wave function V/F
According to a certain period, through triangular wave makes output frequency oscillate.
Parameter
Name
Default Setting Range
Content
10-23
P.234
Triangular wave
function selection
0
0
Off
1
If terminal function TRI is triggered, triangular wave function
will on.
2
Triangular wave function is on at all time.
10-24
P.235
Maximum amplitude
10.0%
0~25.0%
---
10-25
P.236
Amplitude
compensation for
deceleration
10.0%
0~50.0%
---
10-26
P.237
Amplitude
compensation for
acceleration
10.0%
0~50.0%
---
10-27
P.238
Amplitude
acceleration time
10.00s
0~360.00s/
0~3600.0s
When 01-08(P.21)=0, the unit of 10-27(P.238) and
10-28(P.239) is 0.01s.
10-28
P.239
Amplitude
deceleration time
10.00s
0~360.00s/
0~3600.0s
When 01-08(P.21)=1, the unit of 10-27(P.238) and
10-28(P.239) is 0.1s.