Set zone attribution
1
Set No.1 to 8 wired
zone bypass, press 1
2
3
Press 1 to 8,set zones
accordingly
Set No. 1 to 8 wireless
zone bypass, press 2
Set No. 9 to 16 wireless
zone bypass, press 3
Press 1 to 8,set zones
accordingly
Press 1 to 8,set zones
accordingly
Please select zone type code
1:for panic arm 2:for burglar alarm 3:for gas leaking alarm
4:for emergency help 5:for medical help 6:for special alarm
7:for perimeter alarm 8:for Fire alarm
Please choose:press 1 for delay, 0 for instantaneous
1
0
Or
Operation correct,press
#
to confirm,press
*
to exit
4.8 Defense zones' property setting
The property of defense zones means the type of alarms the detector can
send to the CMS. Once it alarms, the panel will send signals as the certain
type to the CMS. Otherwise, when the type of the defense zone has been
set, no matter what type of the alarm is, the panel will send signals as the
certain type set before to the CMS. Time delay means when the detector
alarms, the panel reacts to the signal immediately or later. User can
program the type and time delay according to its needs. Please view the
table 1 to see the type code of defense zones.