Shield Tech Security STS-408 User Manual Download Page 1

Summary of Contents for STS-408

Page 1: ......

Page 2: ...Components list Before installation please check if the whole set including the components as follow User Manual ...

Page 3: ...ity product that has been produced tested and packed w the greatest care Please familiarize yourself with these instructions before attempting to in stall the FOCUS security system because prolonged reliable and trouble free operation will only been sure if it is fitted properly We hope your new FOCUS security system will bring you lasting pleasure User Manual ...

Page 4: ... them one by one or delete them all one time Ten Seconds Alarm information Record 6 Alarm Telephone Numbers 2 for CMS and 4 for common telephones If the control panel does not connect with CMS the total 6 numbers can be set for common telephones Record of clock and alarms built in automatic calendar and clock can help to make record or view 45 alerts and arming disarming affairs and their time Ale...

Page 5: ... by calling CMS Timely Test Setting 4 times auto arm and disarm function can arm and disarm on time And users can also set a auto alarm time the control panel can timely report to the CMS to check its status Wireless Zones supervising tamper alarm low power alarm and status self check System Password and User Password protection there are two types of password system password and user password The...

Page 6: ...on Hint Voice prompt sos LCD disypaly 1 Keypad for operation OR LCD Arm Away Arm Home Requiry Control appliance Panic Bypass Built in Siren MIC StatusLED Record LED Power LED Signal LED Keypad Convoy User Manual ...

Page 7: ...trol panel An obvious feature of the alarm is that it can be installed without open it User just need to connect several wires on the back of the panel 1 Debus the bracket on the back of the panel 2 Make a hole on the wall according to the hole distance on the bottom cover Push the bracket along the arrow pointed Remove the bracket Bracket Mounting hole Pivot Mounting hole Mounting knockout User M...

Page 8: ...e between the control panels and detectors is valid And it is better to put the control panel in a covert place 2 3 Wiring Diagram As the picture Z1 Z5 GND Z2 Z6 Z3 Z7 GND GND Vaux GND GND Z4 Z8 BELL GND Higher zone Lower zone 51K 30K Higher zone Lower zone 51K 30K Metal User Manual ...

Page 9: ...e For NC detector resistance is connected in parallel and for NO detector resistance is connected in series Matching the resistor in lower zone is 30 K Ohm while that in higher zone is 51K Ohm Caution Control panel can supply 12V to detector It can t exceed its current more than 100mA If it exceeds another 12V back up power is necessary for detector operation User Manual ...

Page 10: ...ing press for 3 seconds 9999 2 1 alarm telephone number 3 1 4 Record Alarm Location press for 3 seconds 9999 2 7 face the speaker and speak the location press 10 seconds later the panel will replay the recorded voice If user does not satisfy it user can record again 3 1 5 Register Remote Controller press for 3 seconds 9999 6 1 1 and then press any key on the remote controller if 2 beeps comes out ...

Page 11: ... the key HOME on panel there will be Dee Dee to show you arm the system successfully Panic Press the panic button HELP on controller or press ALARM on panel both could send out information for seeking help and there will be two Dee Dee and auto dial the preset phone number to ask for assistant Disarm User Manual To disarm press DISARM on keyboard or remote control you will hear 2 tick tick sounds ...

Page 12: ...re than 3 seconds Enter user password 1 1 1 1 Enter electronic appliance Number Enter electronic appliance Number Operation correct press to confirm press to exit 1 2 Or The electronic appliance is closed opened 1 8 Enter time for open time switch 1 8 Operation correct press to confirm press to exit Enter time for open time switch Operation correct press to confirm press to exit Note For convenien...

Page 13: ...accordingly Press 1 to 8 set effective bypass zones accordingly Please choose enter 1 for active 0 for bypass Please choose enter 1 for active 0 for bypass Operation correct press to confirm press to exit 1 0 Or Operation correct press to confirm press to exit 1 0 Or 3 3 Operation through a Long Distance Call When receiving an external call after 7 rings the panel takes order Two low tick sounds w...

Page 14: ...1 can re listen the recorded message Press 2 can stop the alarm 3 4 Simple Alarm Test Input user password and perform the operation below Dial the phone number connected to control panel tick tick After phone receives the pre set ringing times control panel sends out 2 tick tick Sound 1 Press 1 key remote away arming 4 Press 4 key switch on siren for 10 seconds this operation can be performed repe...

Page 15: ... will sound a brief sound once you press the keypad effectively When the operation is completed correctly the control panel will sound two ticks to indicate the successful programming Otherwise one long sound indicates wrong operation The key has return function after one setting press the twice can return to upper menu Enter setting status press the key more than 3 seconds enter the system passwo...

Page 16: ...Enter wireless device code press 7 Come back to factory default press 8 Clock setting The time of the panel can be set to the local time which is important for automatic arming disarming and for recording of alarms and time Password setting There are user password and system password The user password the key for user to do the arm disarm and long distance control For the safety of the system we r...

Page 17: ...rd press 2 Modify system password press 3 M M M M M M M M N N N N N N N N Example to show how to modify the time to 9 50 am on 30 March 2006 is given below th 9 Press for 3 seconds 9 9 9 1 1 0 6 Enter year 0 3 3 0 Enter date 0 9 Enter time 5 0 Enter minute Press to confirm Enter the next setting Enter system password Set clock and password press 1 Set time press1 Enter date time and press to confi...

Page 18: ...ock and password press 1 Set user password press2 Enter 4 digit user old password Enter 4 digit user new password Enter 4 digit user new password again Set voice alarm Set voice telephone number press 1 to 6 7 8 Enter telephone number Enter to confirm Enter to exit Setting is saved Enter the next telephone number setting Record alarm address message press 7 Replay the alarm address press 8 1 6 4 5...

Page 19: ...ber The main control panel can be programmed for 6 telephones The maximum digit for the telephone is 15 For example If ST main panel is connected with a extension line then for transferring from the internal line to external line needs to dial 9 or 9 If the receiving phone is 987654321 in line 5 the setting is as shown 9 Press for 3 seconds 9 9 9 2 Press to confirm Enter the next setting Enter sys...

Page 20: ...umber follow the instruction and enter the sequence number user wants to delete and the press 00 can delete it Set network alarm Set center monitoring station telephone number press 1 2 3 4 Operation correct setting is saved enter 4 digit user code Operation correct press to confirm press to exit For Transmit arm disarm information press 3 Enter telephone number Choose Press 1 for active 0 for ina...

Page 21: ...r user code For example sent the arm disarm message to the alarm center station the process is below 1 Press 9 Press for 3 seconds 9 9 9 3 3 Enter system password For Transmit arm disarm information press 3 Please choose press 1 for active 0 for void Operation correct press to confirm press to exit Set network alarm press 3 Notice the control panel does not send message to the CMS every time when ...

Page 22: ... test when the time is 00 00 00 4 7 System Setting This is a personal setting including time delay of enter and exit listen in time cycle alarm times siren on off setting telephone test setting defense zones setting etc 1 When the clock of timely arm disarm is 0 0 0 it means cancel this timely arm disarm set 2 The 4 periods of time should not be superposed or some time period may be invalid 3 If i...

Page 23: ...ration correct press to confirm 7 Please select the type of alarm 0 all types of alarm 1 for panic arm 2 for burglar alarm 3 for gas leaking alarm 4 for emergency help 5 for medical help 6 for special alarm 7 for perimeter alarm 8 for Fire alarm 1 8 Please choose 1 for ON 0 for OFF 1 0 Or Operation correct press to confirm press to exit Enter timing arm disarm time 8 Operation correct setting is s...

Page 24: ... Press for 3 seconds 9 9 9 4 5 Enter system password Set system options press 4 Set rings times press 5 Enter number between 0 9 For example set 8 00 to auto arm time and 17 30 to auto disarm time and this period to be the second arm disarm time 9 Press for 3 seconds 9 9 9 4 8 Enter system password Set system options press 4 Timing arm disarm settings press 8 Set 4 groups of timing arm disarm time...

Page 25: ... delay 0 for instantaneous 1 0 Or Operation correct press to confirm press to exit 4 8 Defense zones property setting The property of defense zones means the type of alarms the detector can send to the CMS Once it alarms the panel will send signals as the certain type to the CMS Otherwise when the type of the defense zone has been set no matter what type of the alarm is the panel will send signals...

Page 26: ... definition perimeter fire alarm alarm alarm alarm help alarm 9 Press for 3 seconds 9 9 9 5 3 2 2 Enter system password Set zone attribution press 5 Set No 9 to 16 wireless zone bypass press 3 Please select zone type code Press 1 to 8 set zones accordingly 0 Please choose press 1 for delay 0 for instantaneous For example set the NO 10 defense zones as burglar alarm zone and alarm immediately Below...

Page 27: ...2 Enroll No 1 to 8 wireless zones press 3 Delete No 1 to 8 wireless zones press 4 Enroll No 9 16 wireless zones press 5 Delete No 9 16 wireless zones Press 6 Enroll No 1 8 electronic switches press 7 Delete No 1 8 enrolled electronic switches press 8 Delete all the enrolled devices in wireless zones press 9 9 Press 1 8 respectively Enroll remote controller detectors and Electronic appliance switch...

Page 28: ...ssword Enroll wireless device press 6 Delete enrolled remote controllers press 2 Press 1 8 respectively delete enrolled remote controller detector and Electronic switch Delete all the enrolled remote controllers press 0 Press key twice to confirm For example register a switch as the third of the panel and then delete it 3 9 Press for 3 seconds 9 9 9 6 1 Enter system password Enroll wireless device...

Page 29: ...sword Enroll wireless device press 6 Delete all the enrolled devices in wireless zones press 9 Press key twice to confirm Enter wireless device code 1 Enter No 1 to 8 remote controller codes press 1 2 3 Enter 1 8 remote controller codes press 1 8 respectively Enter 1 8 wireless detector codes press 1 8 respectively Enter remote controller s 9 digit address code Enter No 1 to 8 wireless zones press...

Page 30: ...ess code 3 4 5 6 7 8 9 In order to avoid the interference user can also input the address code of wireless accessories through the keyboard There is 9 digit code label on the products what you need to do is to input this number Come back to factory default Come back to factory default press 1 Press key twice to confirm Restore password press 2 Restore zone attribution press 3 Restore zone active b...

Page 31: ...repeatedly The alarming center has software to display and process the alarm information 5 3 Common telephone alarm and receiving alarm When answering the alarm call 3 ticks come from the panel and then the panel speaks the alarm location and then listens in for 10 seconds Then 2 beeps from the panel and then comes the voice in struction user can do long distance control trough the telephone Press...

Page 32: ...isarm Telephone line fault Low battery in detector Adequate battery voltage in detector sos Icon Meaning Perimeter zoon Telephone line fault Burglar alarm Panic alarm Help Fire alarm Gas leak Center link failure Special alarm Enroll devices Disarm Away arm Alarm Home arm Icon Meaning Form 4 Icon means on LCD Adequate battery voltage Low battery Alarm information is reporting User Manual ...

Page 33: ...red zones 9 24 means zones 25 means remote controller and panel for help 00 means the telephone line cut or arm disarm 2 the marks on display also indicate alarm 3 LED of signal indicates receiving alarm signal LED of receiving stands for on progress of receiving alarm LED of status means the process of alarm 1 the detectors activated by alarm send alarm information to alarming center 3 sending al...

Page 34: ...nutes immediately 5 6 Detector anti dismantle and alarm 1 If the main control panel receives the signal for detector tamper switch the first time it will deal it as a stealing alarm Then the panel must receive the recover signals will it perform the anti dismantle function 2 Tamper alarm zone is displayed on the LED The status shows the tamper alarm code 14 the icon shows burglar alarm icon 5 7 Ev...

Page 35: ...y can the event recorded Press the key can check the record one by one For example stealing alarm at the fifth wired zone at 8 30 am 3rd April 2006 Press check key Press key enter next information display Check Check Y M D Y M D User Manual ...

Page 36: ...quency 433MHz 0 5MHz The method of alarming dial DTMF DTMF dial frequency variation 1 5 Communication Protocol with CMS Ademco Contact ID 7 3 Physical capability A area data 8 wired defensive areas 16 wireless zones 8 remote controllers B wired area request 51k and 30 k ohm resistance C Zone type robbing alarm thief alarm gas leak alarm ambulance alarm self defined alarm fire alarm and boundary al...

Page 37: ...ppearance and the top transparency of window Chapter 9 Limitation of the Products Although the products is a high standard products there is also some limitation of them such as false alarm or no alarm the reasons may be below Lack of Maintenance The system needs maintenance and test regularly test The sensitive of the detectors may decrease and the siren may not whistle Lack of power supply If no...