![Sherwood Scuba AMPHOS AIR 2.0 Manual Download Page 49](http://html1.mh-extra.com/html/sherwood-scuba/amphos-air-2-0/amphos-air-2-0_manual_1256672049.webp)
49
AMPHOS AIR 2.0 DC MANUAL
© Pelagic, 2019
Doc. No. 12-79 3 9 -r01 (11/12/19 )
SPECIFICATIONS (CONTINUED)
•
Set U Group (Utilities):
• Wet Activation (Off/On)
• Units of Measure (Imperial/Metric)
• No Deco Deep Stop (Off/On)
• No Deco Safety Stop (Off/On)
• Conservative Factor (Off/On)
• Backlight Duration (Off, 5, 10 sec)
• Sampling Rate (2, 15, 30, 60 sec)
• TRT 1 Link Code
• TRT 2 Link Code
NUMERIC DISPLAYS:
Range:
Resolution:
• Time of Day
0:00:00 to 23:59:59 hr:min:sec 1 second
• Temperature
0 to 140°F (-9 to 60°C)
1°
• Watch CDT
23:59 to 0:00 hr:min
1 minute
• Chronograph
0:00:00.00 to 9:59:59.99
.01 second
hr:min:sec .01 sec
• PC Countdown
120 to 0 sec
1 second
• Surface Interval
0:00 to 23:59 hr:min
1 minute
• Time to Fly
23:50 to 0:00 hr:min*
1 minute
(* starting 10 min after the dive)
• Time to Desaturate
23:50 max to 0:00 hr:min*
1 minute
(* starting 10 min. after the dive)
• Dive Number
0 to 24
1
• Depth (Current, Max)
0 to 330 FT (99.9 M)
1 FT (0.1 M )
• Gas 1 FO2 Set Point
Air, 21 to 50 %
1 %
• Gas 2 FO2 Set Point
Air, 21 to 100 %
1 %
• PO2 Value
0.00 to 5.00 ATA
.01 ATA
• DTR (NDC, ATR)
0 to 199 min
1 minute
• Deep Stop Time
2:00 to 0:00 min:sec
1 second
• Safety Stop Time
3:00 to 0:00 min:sec
1 second
• Deco Stop Time
0:00 to 1:59 hr:min
1 minute
• Deco TAT
0 to 199 min
1 minute
• EDT
0:00 to 9:59 hr:min
1 minute
• Tank Pressure
0 to 5000 PSI (345 BAR)
5 PSI (1 BAR)
• Free Dive Number
0 to 99
1
• Free Surface Interval
0:00 to 59:59 min:sec
1 second
1:00 to 23:59 hr:min
1 minute
• Free CDT
59:59 to 0:00 min:sec
1 second
• Free EDT
0:00 to 59:59 min:sec
1 second
• Depth Out of Range
=> 330 FT (99.9 M)
• Violation Countdown
23:50 to 0:00 hr:min (after surfacing)
BAR GRAPHS
Nitrogen Bar Graph:
segments
• No Deco Normal zone 3
• No Deco Caution zone 1
• Deco Warning zone 1
Oxygen (O2) Bar Graph:
segments
• Normal zone
3
• Caution zone
1
• Danger zone
1
Ascent Rate Indicator:
60 FT (18 M) & Shallower
Deeper than 60 FT (18 M)
segments
FPM
MPM segments
FPM
MPM
0 0 - 10 0 - 3 0 0 - 20
0 - 6
• Normal
1 11 - 25 3.5 - 7.5 1 21 - 50
6.5 - 15
• Caution
2 26 - 30 8 - 9 2 51 - 60
15.5 - 18
• Too Fast (flashing)
3 (all) > 30 > 9 3 (all) > 60
> 18
Summary of Contents for AMPHOS AIR 2.0
Page 5: ...5 AMPHOS AIR 2 0 DC MANUAL Pelagic 2019 Doc No 12 79 3 9 r01 11 12 19 FEATURES DISPLAYS...
Page 8: ...8 AMPHOS AIR 2 0 DC MANUAL Pelagic 2019 Doc No 12 79 3 9 r01 11 12 19 WATCH FEATURES DISPLAYS...
Page 23: ...23 AMPHOS AIR 2 0 DC MANUAL Pelagic 2019 Doc No 12 79 3 9 r01 11 12 19 NORM DIVE MODES...
Page 28: ...28 AMPHOS AIR 2 0 DC MANUAL Pelagic 2019 Doc No 12 79 3 9 r01 11 12 19 CAUTIONARY MODES...
Page 43: ...43 AMPHOS AIR 2 0 DC MANUAL Pelagic 2019 Doc No 12 79 3 9 r01 11 12 19 REFERENCE...
Page 53: ...53 AMPHOS AIR 2 0 DC MANUAL Pelagic 2019 Doc No 12 79 3 9 r01 11 12 19 NOTES...