![Sherwood Scuba AMPHOS AIR 2.0 Manual Download Page 44](http://html1.mh-extra.com/html/sherwood-scuba/amphos-air-2-0/amphos-air-2-0_manual_1256672044.webp)
44
AMPHOS AIR 2.0 DC MANUAL
© Pelagic, 2019
Doc. No. 12-79 3 9 -r01 (11/12/19 )
CARE AND CLEANING
Protect your AMPHOS AIR 2.0 from shock, excessive temperatures, exposure to chemicals, and tampering. Protect the lens against scratches
with a Instrument Lens Protector. Small scratches will naturally disappear underwater.
• Soak and rinse the AMPHOS AIR 2.0 in fresh water at the end of each day of diving, and check to ensure that the areas around the Low
Pressure (Depth) Sensor (Fig. 120a), PC Interface Data Port (Fig. 120b), and Buttons are free of debris or obstructions. Soak and rinse
the Regulator(s) with the Transmitter(s) attached.
• To dissolve salt crystals, use lukewarm water or a slightly acidic bath (50% white vinegar/50% fresh water). After removal from the
bath, place the AMPHOS AIR 2.0 and the Regulator(s) with Transmitter(s) unit under gently running water and towel dry before storing.
• Transport your AMPHOS AIR 2.0 system cool, dry, and protected.
INSPECTIONS AND SERVICE
Your AMPHOS AIR 2.0 should be inspected annually
by an Authorized Sherwood Dealer who will perform a factory prescribed function
check and inspection for damage or wear. To keep the 2 year limited warranty in effect, this inspection must be completed one year after
purchase (+/- 30 days).
Sherwood recommends that you continue to have an inspection performed every year to ensure it is working properly. The costs of annual
inspections are not covered under the terms of the 2 year limited warranty.
To Obtain Service:
Take your AMPHOS AIR 2.0 system to an Authorized Sherwood Dealer.
AMPHOS AIR 2.0 BATTERY REPLACEMENT
NOTE: The procedures that follow must be closely adhered to. Damage due to improper Battery replacement is not
covered by the product's warranty.
The Battery Compartment should only be opened in a dry and clean environment with extreme care taken to prevent the entrance of moisture
or dust.
As an additional precautionary measure, to prevent formation of moisture in the Battery Compartment, it is recommended that the Battery be
changed in an environment equivalent to the local outdoor temperature and humidity (e.g., do not change the Battery in an air conditioned
environment then take it outside during a hot sunny day).
Inspect the Buttons, Lens, and Housing to ensure they are not cracked or damaged. If there is any sign of moisture in the AMPHOS AIR 2.0,
DO NOT attempt to use it for diving (NORM, GAUG, or FREE) until it receives proper factory service by Sherwood.
NOTE: When the old battery is removed, settings and calculations for repetitive dives will be retained in non volatile
memory for subsequent operations.
CAUTION: Damage due to improper Battery replacement is not covered by the product's warranty.
Battery Removal
• Locate the Battery Compartment on the back of the unit.
• Rotate the Battery Cover clockwise 10 degrees using the special Battery Cover Tool provided (Fig. 121), or -
by pushing the lower portion to the left while pushing the upper portion to the right using your fingers (Fig. 122).
• Lift the Cover with O-ring up and away from the Housing.
• Using care not to damage the Battery Contact (Fig. 123a), slide the Battery up and out of the left side of the Battery Compartment.
• Discard the Battery according to local regulations governing disposal of Lithium batteries.
CAUTION: DO NOT allow a metal object to short circuit the top of the Battery which is positive (+) to the negative ( - )
contact of the Battery Compartment.
Inspection
• Closely check all of the sealing surfaces for any signs of damage that might impair proper sealing.
• Inspect the Buttons, Lens, and Housing to ensure they are not cracked or damaged.
• Remove the Battery Cover O-ring and inspect it for any signs of deterioration or deformity. DO NOT use tools to remove the O-ring.
• To ensure proper sealing, O-ring replacement is highly recommended each time a Battery is replaced.
• Closely examine the Battery Cover and Housing for any signs of damage that might prevent proper sealing.
• Closely examine the inside of the Battery Compartment for any signs of corrosion indicating entrance of moisture into the unit.
WARNING: If damage or corrosion is found, return your AMPHOS AIR 2.0 to an Authorized Sherwood Dealer, and DO
NOT attempt to use it until it has received factory prescribed service.
Battery Installation
• Slide a new 3 volt type CR2430 Lithium Battery, negative side down into the cavity of the compartment. Slide it in from the left side (Fig.
124) and ensure that it slides under the contact clip on the lower/right rim of the cavity.
• Lightly lubricate the new Cover O-ring with silicone grease and place it on the inner rim of the Battery Cover. Ensure that it is evenly
seated (Fig. 125).
Fig. 120 - CASE BACK
b
a
Fig. 121 - BATTERY Cover
REMOVAL (Tool)
Fig. 122 - ALTERNATE
Cover REMOVAL
Fig. 123 - AMPHOS AIR 2.0
BATTERY REMOVAL
a
Fig. 124 - BATTERY
INSTALLATION
Fig. 125 - Cover O-RING
Summary of Contents for AMPHOS AIR 2.0
Page 5: ...5 AMPHOS AIR 2 0 DC MANUAL Pelagic 2019 Doc No 12 79 3 9 r01 11 12 19 FEATURES DISPLAYS...
Page 8: ...8 AMPHOS AIR 2 0 DC MANUAL Pelagic 2019 Doc No 12 79 3 9 r01 11 12 19 WATCH FEATURES DISPLAYS...
Page 23: ...23 AMPHOS AIR 2 0 DC MANUAL Pelagic 2019 Doc No 12 79 3 9 r01 11 12 19 NORM DIVE MODES...
Page 28: ...28 AMPHOS AIR 2 0 DC MANUAL Pelagic 2019 Doc No 12 79 3 9 r01 11 12 19 CAUTIONARY MODES...
Page 43: ...43 AMPHOS AIR 2 0 DC MANUAL Pelagic 2019 Doc No 12 79 3 9 r01 11 12 19 REFERENCE...
Page 53: ...53 AMPHOS AIR 2 0 DC MANUAL Pelagic 2019 Doc No 12 79 3 9 r01 11 12 19 NOTES...