BPS – K – 3.0 – 6.0
Sherpa
Autodiagnostik
page: 29
9.5
Error checklist
9.5.1
Initial fault clearance activities
Error
(No operation of the test stand is possible. Use the automatic button to “zip” through the errors).
Cause
Illustration
(scale 0-40))
Remedy
Possible cause(s)
Fault / Error message
Corrective Actions
no power supply
no LED lights up
check the fuse of the power
supply
insufficient power supply
test stand does not perform
unusual sound coming from the
engine
check the fuse of the power
supply
failure on bus connection
malfunction of a bus user
all LEDs are flashing (master
display)
all LEDs are lit up (simultaneous
display)
no operation possible
check the fuse in the control box
please contact us on our service
address
braking force sensor left – line
break
orange LED flashes
right pointer – 1
check the cabling
braking force sensor right – line
break
orange LED flashes
right pointer – 2
check the cabling
slip sensor roll left – line break
orange LED flashes
right pointer – 3
check the cabling
slip sensor roll right – line break
orange LED flashes
right pointer – 4
check the cabling
sensor left –
line break
orange LED flashes
right pointer – 5
check the cabling
sensor right – line break
orange LED flashes
right pointer – 6
check the cabling
braking force sensor left or slip
sensor roll left –
increased defect
orange LED flashes
right pointer – 7
replace the sensor
braking force sensor right or slip
sensor roll right –
increased defect
orange LED flashes
right pointer – 8
replace the sensor
sensor left –
increased defect
orange LED flashes
right pointer – 9
replace the sensor
sensor right –
increased defect
orange LED flashes
right pointer – 10
replace the sensor
slip sensor engine left – line
break
orange LED flashes
right pointer – 11
check the cabling
slip sensor engine right – line
break
orange LED flashes
right pointer – 12
check the cabling
slip sensor engine left –
orange LED flashes
replace the sensor