12. InSTAllInG THe coVeR on THe FRAme

Fig.12A

Fig.12B

Fig.12C

Fig.12D

1

. Lay the cover on the ground next to the 

frame with the inside of the cover (the side 

with the pipe pockets) facing down and the 

webbing on the front and rear of the corner 

of the building.  Position the cover so that it is 

centered on the frame, front to back. 

Fig. 12A

 

2

. Fold over the side closest to the frame so 

the pipe pocket is now accessible. Insert a 

cover pipe at the first middle rib from the front 

and the first middle rib from the rear so that it 

is inserted in the pipe pocket on both ends of 

the pipe but the center of the pipe is exposed.  

For long buildings it may be necessary to use 

additional pipes in the middle. 

Fig. 12B

 

3

. Tie the rope on each of the exposed pipes 

and throw the other end of the rope over the 

frame. 

Fig. 12C

 4

. Move to the other side of the frame and pull 

the cover over the frame with the rope.  This 

may require two or more people. 

FIg. 12D

END PANELS 

NOT SHOWN 

FOR CLARITY. 

noTe: cHeck THAT YoUR coVeR IS 

coRRecTlY PlAced on THe FRAme.  

The ShelterLogic

®

 logo should line up on the left front and 

right rear corners near the top rail. If the logo is not legible, 

the cover has not been put on the frame correctly.

Summary of Contents for 107153

Page 1: ...ze of your building Allow approximately 15 minutes for every foot in building length Please read instructions COMPLETELY before assembly This shelter MUST be securely anchored THIS IS A TEMPORARY STRU...

Page 2: ...terLogic LLC Shelters offer storage and protection from damage caused by sun light rain tree sap animal bird excrement and light snow Please anchor this ShelterLogic LLC structure properly See manual...

Page 3: ...135 14 11107 2 11136 15 11270 3 11013 16 11130 4 11016 17 11131 5 11019 18 800454 6 11068 19 11133 7 11095 20 11134 8 11101 21 00648 9 11102 22 11093 10 11103 23 04551 11 11104 24 800053 12 11105 25 8...

Page 4: ...f the shelter Fig 1 2 To be sure the staked area is square tie a rope diagonally from corner to corner 3 Measure from where the two ropes intersect each other to all 4 corners This measurement should...

Page 5: ...ctions that do not use a wind brace use a 4 1 8 bolt 800454 800372 00690 800454 6 Install Wind Braces Attach wind brace between the end rib and the first middle rib as shown in Fig 6 Use 11134 Bolt Bo...

Page 6: ...r and around the frame as indicated in Fig 10 Secure the cable with the clamp s provided Fig 10 End Rib Anchors Middle Rib Anchors 11105 8 Sliding cover rail assembly A Place a Cover Rail Pipe 11105 b...

Page 7: ...the cross rail and wind brace Replace the nut and tighten Repeat this on the other side D At the bottom where the webbing exits the pocket on each side of end panel pull webbing to remove the slack Be...

Page 8: ...le rib from the rear so that it is inserted in the pipe pocket on both ends of the pipe but the center of the pipe is exposed For long buildings it may be necessary to use additional pipes in the midd...

Page 9: ...tchet so that the webbing overlaps itself D Disassemble cover rails and slide through fabric pockets at each leg and reattach with clamps to each leg Repeat this on other side Push down on cover rails...

Reviews: