background image

25

Warranty 

Information 

CERTIFICATE OF LIMITED WARRANTY:

EXTENT OF COVERAGE: This warranty covers Shelter Furnaces SF4200, sold in the United States and Canada. This warranty is void if 

the Shelter Furnace is not installed, maintained, and operated in accordance with the instructions in the owner’s manual and local codes.  

Warranty is also null and void if the unit is used to burn materials for which the unit is not certified by the EPA. This warranty applies to 

the original purchaser/owner of the Shelter Furnace and is not transferable.  Replacement or repair parts are warrantied for the remaining 

period of the original warranty.

All warranty claims must include: 

• Date of purchase
• Model and serial number
• Proof of purchase – dated invoice, bill of sale, cancelled check or payment record
• Name and address of the dealer where the unit was purchased

Shelter Furnace warranties the cast iron grates and firebox to be free of defects in material and workmanship for five years to the original 

purchaser. Intentional misuse or abuse causing burn through of the cast iron components voids all warranties.  Over firing the furnace will 

cause the front face to crack and is not covered by the warranty.  Furthermore, some cosmetic deterioration can be expected as the 

result of normal operation, therefore the physical appearance is not guaranteed to remain unchanged.  The manufacturer warranties all 

electrical components for 1 year and the draft blower and distribution motor for 

1

 year.  Please be advised that the firebrick and door 

gaskets are excluded from this warranty.

In order to exercise the aforementioned warranty, a certified professional must determine the appliance/part to be defective.  He or she 

must submit a written statement to Shelter Furnace detailing an assessment of the problem.  This assessment MUST be accompanied by 

substantiating proof of purchase (dated invoice, bill of sale, cancelled check, or payment record), model and serial number.  Shelter 

Furnace will then authorize repair or replacement appropriate to the submitted claim.  Shelter Furnace will not honor expenses incurred 

from any action that was not expressly consented to in writing.  The owner is hereby notified that he or she will be obligated to assume 

liability for removal, reinstallation, shipping, and labor costs involved in servicing/repairing or replacing the part or unit.  The merchandise 

in question must be shipped via PREPAID FREIGHT to Shelter Furnace.  Shelter Furnace will return the repaired or replacement part to 

the purchaser on a FREIGHT COLLECT basis.

This warranty will be rendered null and void if this part/unit exhibits symptoms of obvious over-firing, deliberate abuse or negligence, 

improper installation, or is used for commercial purposes.

Finally, Shelter Furnace will not be responsible for any claim not stated in our warranty nor does any implied warranty extend beyond the 

limits stated above.

If you are unable to receive satisfactory service, please contact Shelter Furnace with all pertinent information including daytime phone 

number and a detailed description of the type of problem you are having.  Shelter Furnace technical service will contact you as soon as 

possible.  Call 1-800-875-4788 or mail information to: Shelter Furnace, 10950 Linpage Place, Saint Louis, MO  63132.  

Summary of Contents for SF4200

Page 1: ...DOOR FURNACE MODEL SF4200 Manufactured by Shelter Furnace 10950 Linpage Place Saint Louis MO 63132 1 800 875 4788 MADE IN USA October 2016 Tested to UL391 and CSA B366 1 2011 and B415 1 2010 Standards...

Page 2: ......

Page 3: ...tput Wood that is properly cut and stored to dry will produce more BTUs and higher heat output than wood that has a higher moisture content Wood with higher moisture content will create creosote in th...

Page 4: ...rnace has been tested for clearance of 12 inches from the home this would give maximum airflow and provide the highest efficiency Transportation Damage Every effort has been made to ensure that your S...

Page 5: ...ion 11 General Operation 12 FIRST FIRE 12 LOADING WOOD 12 Fuel Recommendations 13 Disposal of Ashes 13 Heat Dump and Fuse Link System 14 Draft Blower 14 CREOSOTE FORMATION 14 CREOSOTE PREVENTION 15 Po...

Page 6: ...of these features as standard equipment offering you the most efficient durable and affordable appliance possible Abnormally cold weather could reduce the burn time Your Shelter Furnace is designed to...

Page 7: ...ot interchange with other brands A tube of high temp silicone caulk is included with your furnace Before using the silicone to install the anchor plate to the top of your Shelter Furnace ensure the ch...

Page 8: ...1 800 875 4788 THIS UNIT IS NOT TO BE CONNECTED TO A CHIMNEY FLUE THAT SERVES ANOTHER APPLIANCE INSTALLING THE ANCHOR PLATE Note Check with your dealer for the anchor plate that connects to Class A HT...

Page 9: ...up the chimney the length of the measurement increases Once this measurement reaches 10 feet this height on the chimney is your base height The chimney must be 2 feet taller than the base height If th...

Page 10: ...minimum Use Class A HT 2100 All Fuel 6 Inch Chimney for your Shelter Furnace Never use galvanized pipe in your flue connection Inspect the flue periodically for structural integrity Clean the flue reg...

Page 11: ...od or particleboard The prohibition against burning these materials does not prohibit the use of fire starters made from paper cardboard saw dust wax and similar substances for the purpose of starting...

Page 12: ...air duct vent as well as the vent for the cold air return The cold air return is an integral part of the system and must be used when installing the furnace Failure to use cold air return will pressur...

Page 13: ...ted insulated flexible hot air duct to connect the central duct system for the home When using flexible duct inside the home it must be pulled tight with no offsets or elbows to prevent turbulence and...

Page 14: ...rn Ideally locate each at opposite ends of the home If you don t the air will not flow evenly throughout the home This method will work well on homes built on concrete slabs and help create a good air...

Page 15: ...operating at full capacity The new steel and metal components of the furnace have a protective coating or paint on the surface which could produce an odor during the break in period Adequate ventilat...

Page 16: ...into a metal container with a tight fitting lid The closed container of ashes should be placed on a non combustible floor or on the ground well away from all combustible materials pending final dispo...

Page 17: ...motor turns on and supplies fresh air into the firebox producing a hotter fire which in turn provides more heat in the heat chamber The heat is then sent through the duct system throughout your home W...

Page 18: ...lammable liquids inappropriate materials Maintaining Your Furnace At the beginning of each heating season take time to thoroughly check your furnace and chimney system Make sure there are no leaks whe...

Page 19: ...e in any way CAUTION HOT SURFACES KEEP CHILDREN AWAY DO NOT TOUCH DURING OPERATION CAUTION INSPECT FLUE PIPES JOINTS AND SEALS REGULARLY TO ENSURE THAT SMOKE AND FLUE GASES ARE NOT DRAWING INTO AND AR...

Page 20: ...lower and motor pulleys may be changed but the electrical current flowing through the motor cannot exceed the nameplate rating On a direct drive system the motor should not be changed however the spee...

Page 21: ...1 4 PARTS LIST DESCRIPTION QTY ITEM BLOWER WHEEL 1 1 BLOWER HOUSING 1 2 MOTOR CAPACITOR 1 3 BLOWER MOTOR 1 4 2 1 3 4 1 2 2 3 2b 5 4b 5 4 SF4200 PARTS LIST ITEM QTY PART DESCRIPTION 1 1 FC000 ROLLER GR...

Page 22: ...B FAN LIMIT CONTROL WALL THERMOSTAT 120V AC 24V AC TRANSFORMER RELAY DRAFT BLOWER MOTOR BLOWER MOTOR BLACK 120V AC POWER SUPPLY WHITE BLACK GREEN BLACK WHITE YELLOW RED RED RED YELLOW BLACK ORANGE WIR...

Page 23: ...rnace not providing enough heat Furnace size is inadequate for your home 2 Open slide cover to an opening of approximately 3 8 inches Completely avoid using if at all possible If circumstances necessi...

Page 24: ...t accumulation surrounding air registers in the home Possible Causes Remedies Furnace is not connected to return air duct and is disbursing dirt throughout home Connect to return air duct system Insta...

Page 25: ...gases which causes them to condense as creosote on the inside of the flue Using uninsulated stove pipe for the chimney Problem Smoke from the fire chamber is puffing back through the forced draft mot...

Page 26: ...turing process Firing the furnace has raised the tempera ture of the fire box to a level that is sufficient to vaporize the residue The odor should disappear after a few hours of usage Possible Causes...

Page 27: ...nction containing gases within the fire chamber Possible Causes Remedies 17 Insufficient natural draft or an obstruction in the flue system See 8 9 and 16 Fire chamber filled to capacity with unburned...

Page 28: ...xcluded from this warranty In order to exercise the aforementioned warranty a certified professional must determine the appliance part to be defective He or she must submit a written statement to Shel...