SHELTER INDOOR FURNACE MANUAL

MODELS: SF2600, SF3100

EPA Certified to the Warm Air Furnace NSPS requirements, for sale May 2017 through May 2020.

SAVE THESE INSTRUCTIONS

Congratulations!  You have selected the finest quality wood burning indoor furnace, manufactured with pride in the USA.  

Please take a few moments to carefully read the owner’s manual.  By taking the time to familiarize yourself with your new 

Shelter Furnace, you will be able to look forward to years of trouble-free, dependable service.

Installation:

First: Check local codes.  The installation must comply with all local rules and requirements.

Furnace installation is to be performed by a qualified installer.  This furnace must not be installed in trailers, modular or mobile 

homes.  Always have a properly installed and functioning smoke detector in your home.  To prevent accidental injury, do not 

allow anyone who is unfamiliar with the furnace to operate it.  Spend time familiarizing yourself with your Shelter Furnace, 

especially the different settings and the effects they have on burn patterns.  It is impossible to predict how each setting 

will affect your furnace due to variations in conditions, fuels and temperatures.

Transportation Damage:

Every effort has been made to ensure that your Shelter Furnace will arrive in perfect condition.  Any visible damage should be 

noted on the freight bill at the time of delivery.  If upon unpacking your Shelter Furnace you find damage has occurred during 

transit, notify your supplier immediately.  Your supplier will advise you what actions must be taken to address the problem.

Disclaimer Notice:

The listed BTU rating for your new Shelter Furnace was obtained using laboratory calculations.  The actual BTU output you 

experience may vary somewhat depending on the type, condition and moisture content of the fuel used, damper 

adjustment, chimney type and other factors.  Therefore, the manufacturer disclaims any guarantee as to the BTU output 

or capacity.  Shelter Furnace disclaims any responsibility for the following: installation of a furnace that has been altered 

or modified in any way; installation of the furnace other than as instructed in this manual; installation and/or use of any 

component or part not approved by Shelter Furnace for use with this furnace.  Be sure to complete and return your warranty 

card within 30 days of purchase in order to activate warranty coverage on your furnace.

Manufacturer’s Notice:

Please be advised that we periodically make changes to improve our products, therefore the information in this manual may 

not be completely applicable to your Shelter Furnace.  Please refer to markings on the appliance for additional information.

THIS IS A WOOD BURNING FURNACE ONLY AND SHOULD NOT BE ALTERED 

IN ANY WAY.

Summary of Contents for SF2600

Page 1: ...FURNACE MODELS SF2600 SF3100 Manufactured by Shelter Furnace 10950 Linpage Place Saint Louis MO 63132 1 800 875 4788 MADE IN USA October 2016 Tested to UL391 and CSA B366 1 2011 and B415 1 2010 Stand...

Page 2: ......

Page 3: ...put Wood that is properly cut and stored to dry will produce more BTUs and higher heat output than wood that has a higher moisture content Wood with higher moisture content will create creosote in the...

Page 4: ...will arrive in perfect condition Any visible damage should be noted on the freight bill at the time of delivery If upon unpacking your Shelter Furnace you find damage has occurred during transit noti...

Page 5: ...RMATION 13 CREOSOTE PREVENTION 13 Chimney Fire Warning 14 Power Failure 14 Furnace Diagram with Parts List 15 Grate System Diagram SF2600 16 Grate System Diagram SF3100 16 Blower Motor Assembly Diagra...

Page 6: ...nce with a nationally recognized safety standard and within clearances specified on the nameplate When in a parallel installation the static pressure of the central furnace plenum may not exceed 0 15...

Page 7: ...up in the furnace causing the blower to short cycle and damage the blower motor and will not be covered under warranty This is not a down draft furance and not to be installed as one If you do not hav...

Page 8: ...o the circulation blower using 4 20 bolts and nuts Line up the blower with the pre drilled holes on the backside of the furnace firmly attach with the screws provided 2 Attach blower to the left and r...

Page 9: ...osure covering the rear distribution blower Make sure the filter box is tightly pressed to the back of the furnace Use 6 8 self tapping screws included to firmly attach the filter box to alignment hol...

Page 10: ...asured with the use of a draft gage or manometer If there is more than 08 water column inches of draft it can be adjusted with the installation of a flue damper The stovepipe required to connect the f...

Page 11: ...g a brick chimney you must line the entire chimney with stainless steel liner The liner must be the correct size for the furnace SF2600 and SF3100 6 liner The diameter of the chimney stack should be c...

Page 12: ...together The return air system should be a minimum of 10 larger than the heat outlet to readily transfer the cold air back to the furnace Avoid using 90 elbows in duct runs 45 elbows provide better ai...

Page 13: ...acked to provide a free flow of air between the logs thus allowing more rapid seasoning of the wood If wood is stored outdoors it should be completely covered year round to protect it from moisture an...

Page 14: ...stion of these substances may release harmful toxic gases Do Not Burn Garbage Lawn clippings or yard waste Materials containing rubber including tires Materials containing plastic Waste petroleum prod...

Page 15: ...nstance 2 to 4 hours you are over firing your furnace This type of occurrence is usually symptomatic of heat demands in excess of furnace capacity Contact an authorized professional to determine if yo...

Page 16: ...tarted with a capacitor that draws a maximum of 5 amps when set at high speed The 3 speed switch on your electrical control center allows you to manually adjust speeds to your desired setting If you a...

Page 17: ...w burn rate that must not be altered It is against federal regulations to alter this setting or otherwise operate this wood heater in a manner inconsistent with operating instructions in this manual A...

Page 18: ...MBLY INDOOR WAF IECA WAF IECA 8 1 BLOWER ASSEMBLY FC3SPMOTOR FC3SPMOTOR 8a 1 BLOWER MOTOR FCDD037P FCDD037P 8b 1 BLOWER HOUSING FCBH FCBH 9 2 FILTER BOX SIDE WAF FBS WAF FBS 10 1 FILTER BOX TOP WAF FB...

Page 19: ...EXTENSION BASE SHORT 4 1 FC000 ROLLER GRATE EXTENSION SHORT 5 1 FC000 ROLLER GRATE 6 6 FIRE BRICK SF3100 PARTS LIST ITEM QTY PART DESCRIPTION 1 1 FC000 ROLLER GRATE HANDLE 2 1 ROLLER GRATE BASE 2b 1 R...

Page 20: ...ram PARTS LIST DESCRIPTION QTY ITEM BLOWER WHEEL 1 1 BLOWER HOUSING 1 2 MOTOR CAPACITOR 1 3 BLOWER MOTOR 1 4 2 1 2 3 17 PARTS LIST DESCRIPTION QTY ITEM BLOWER WHEEL 1 1 BLOWER HOUSING 1 2 MOTOR CAPACI...

Page 21: ...T 120V AC 24V AC TRANSFORMER RELAY DRAFT MOTOR ON OFF SWITCH 3 SPEED SWITCH DRAFT BLOWER MOTOR 3 SPEED BLOWER MOTOR BLUE MED RED LOW BLACK HI 120V AC POWER SUPPLY WHITE BLACK GREEN BLACK WHITE YELLOW...

Page 22: ...ower vibrates during operation Screw on squirrel cage is not tight Check squirrel cage alignment and position so that it does not drag on the housing during rotation then tighten the screw sufficientl...

Page 23: ...eturn air duct system Install filter box on furnace Install filter in filter box Filter box not installed or no filter in filter box 5 Problem Smoke from the fire chamber is puffing back through the f...

Page 24: ...e Install flue gas thermometer and maintain stack temperatures between 300 and 400 F See 9 Insufficient chimney draft 8 Improper connection in stove pipe causing air leakage or a structural defect in...

Page 25: ...obstruction outside chimney such as a tree Flue is located too close to the peak of the roof or does not rise above it to provide the proper draft Backdraft damper is in the closed position 9 Problem...

Page 26: ...ns of insect infestation such as burrows or holes avoid using if possible Do not store wood indoors Possible Causes Remedies 13 Problem Circulation blower will not turn on Defective fan limit control...

Page 27: ...tive He or she must submit a written statement to Shelter Furnace detailing an assessment of the problem This assessment MUST be accompanied by substantiating proof of purchase dated invoice bill of s...

Page 28: ......