Shell SBC100 User Manual Download Page 4

1. Check the battery chemistry and voltage before charging it with our 

    product. The battery information can be found in the vehicle's owner's

    manual.

2. Turn off the power loads such as headlamps, air-conditioning and 

    radio before charging the battery.

1. Connect the battery clamps or eyelet terminal connectors to the DC 

   connector of the battery charger.

2. Plug the charger into an outlet. The red power Indicator will turn on.

    At the same time 6V SLA and 12V SLA indicators will flash alternately.

3. To charge a 12V Li-ion battery, change the battery type by pressing 

    the “MODE” 

        

to toggle to 12V Li-ion battery. The green indicator 

    light for 12V Li-ion battery will turn on. Otherwise, go to step 4. 

4. Connect the black battery clamp or eyelet terminal connector to the 

    negative (NEG, N, -) battery terminal.

5. Connect the red battery clamp or eyelet terminal connector to the 

    positive (POS, P, +) battery terminal.

6. The charger will auto-detect the voltage of the SLA battery and the 

    green indicator light of the detected battery type will flash. 

    • If 12V Li-ion is selected, the corresponding indicator will flash.  

    • To change the charging voltage of the SLA battery, follow the 

        instruction of Mode change.

7. The charger will now go through the pre-programmed charging steps. 

    The corresponding battery type indicator will keep flashing.

    • Refer to the table below for the explanation of the indicator lights.

8. When charging is finished and the battery is confirmed to be in good  

    condition, the battery type indicator will turn to solid green. The 

    charger will go into the maintenance step and will trickle charge the 

    battery as needed. The charger can be disconnected from the battery 

    at any time. 

9. When disconnecting the battery charger, unplug the charger from the 

    outlet first. Remove the black clamp and then the red clamp or directly   

    remove the eyelet terminal connectors.

If the charger fails to detect a 12V SLA battery, press and hold “MODE” 

    

       for 3 seconds, the charging mode will be changed from 6V SLA to 

12V SLA. 

Before connecting to the battery

Charging setup

Mode change

Summary of Contents for SBC100

Page 1: ...SBC100 Battery Charger Maintainer User Guide ITM ART 1602693...

Page 2: ...information on safe operation and use To ensure long life and performance reliability please operate and maintain as per the instructions on this sheet For Your Safety Product Details Battery Charger...

Page 3: ...levels of safety protection Product Features Package Includes 1 x Battery Charger 1 x Fused Battery Clamps 1 x Eyelet Terminal Connectors 1 x User Guide 1 x Product Warranty Registration Note This pro...

Page 4: ...t the voltage of the SLA battery and the green indicator light of the detected battery type will flash If 12V Li ion is selected the corresponding indicator will flash To change the charging voltage o...

Page 5: ...urrent will be applied in order to prepare the battery for the next charging step LED Indicator Light Table LED Indicator Explanation Indicator Light Red light on Power indicator Plug in the charger a...

Page 6: ...Bulk Charging The battery is charged at a constant current of 1A This stage will charge the battery to approximately 85 of full charge Absorption The charger switches to constant voltage charging Cha...

Page 7: ...A indicators flash alternately ERR indicator flashes Battery clamps are loose or not connected to the battery Fuse on the eyelet terminal connectors may be blown Reconnect battery clamps to the batter...

Page 8: ...rating Temperature 10 C to 45 C Storage Temperature 20 C to 55 C Product Dimensions 3 56 x 2 47 x 1 98 inches 90 42 x 62 0 x 50 29 mm Product Weight 0 38 0 02 lb 175 10 g Accessories Battery Clamps 27...

Page 9: ...an extension cord with this product The product may become warm under extended high power operation Do not disassemble modify or repair this product Do not destroy product by crushing or cutting Do no...

Page 10: ...t the battery or other electrical part that may cause explosion Incompatible or damaged car batteries may explode when used with this product This device complies with part 15 of the FCC Rules Operati...

Page 11: ...the interference by one or more of the following measures reorient or relocate the receiving antenna increase the separation between the equipment and receiver connect the equipment into an outlet on...

Page 12: ...IBILITY OF SUCH DAMAG ES THE WARRANTIES SET FORTH HEREIN ARE IN LIEU OF ALL OTHER WARRANTIES EXPRESS IMPLIED STATUTORY OR OTHERWISE INCLUDING WITHOUT LIMITATION THE IMPLIED WARRANTIES OF MERCHANTABILI...

Page 13: ...tained c are were modified without the express written consent of Shell d have been disassembled altered or repaired by anyone other than Shell e had defects which were reported after the Warranty Per...

Page 14: ...SH SBC100 IM ENG D10057R2 SBC100 Battery Charger Maintainer Printed in China...

Reviews: