Shearwater Research Inc.
Revision 1.1.0
38
Shearwater Petrel
Pushing MENU will continue to increment the gas number�
Note: The “A” denotes the active gas� You cannot delete the
active gas� If you try, it will generate an error� You can edit it,
but cannot set both the O2 and HE to 00�
The computer will display all 5 gas entries available to allow you to
enter new gases�
Pressing MENU one more time when the fifth gas is displayed will
return you to the “Define Gas” menu item.
DEPTH TIME STOP TIME
DEPTH TIME STOP TIME
DEPTH TIME STOP TIME
Next Gas
Done
Change
HE%
Edit
Edit
Save
O
O
O
A3 OC On 14/55
5 OC On OO/OO
2 OC On 5O/OO
.85 .86 .84
.85 .86 .84
.85 .86 .84
Only turn-on gases you are carrying
Only turn on the gases you are actually carrying on the dive� With radio station gases,
the computer has a full picture of the OC and CC gases you are carrying and can make
informed predictions about decompression times� There is no need to turn gases off
and on when you switch from CC to OC, because the computer already knows what the
gas sets are� You should have the CC and OC gases you are actually carrying turned
on�
If you often use other gases, but not on this dive, you can enter the gas and turn it off�
You can turn gases on and off during a dive and you can also add or remove a gas dur-
ing the dive if needed�
Summary of Contents for Petrel EXT