Page 41
Doc. 13301-Tec-RevB (2022-05-25)
Technical Modes
Operating Instructions
Turn on the Transmitter
Turn on the transmitter by opening the tank valve� The
transmitter will automatically wake up when it detects
pressure�
Pressure data is transmitted approximately every 5
seconds�
Turn off the Transmitter
To turn off the transmitter, close the tank valve and
purge the second stage regulator to drain pressure
from the hoses� The transmitter will automatically
power down after 2 minutes of no applied pressure�
Enable AI on the Perdix 2
On the Perdix 2, navigate to the
System Setup
>
AI
Setup� Change the
AI Mode
setting to
On.
Pair the Transmitter
Each transmitter has a unique serial number etched
on its body� All communications are coded with this
number so that the source of each pressure reading
can be identified�
When
AI Mode
is set to
Off
, the AI sub-system is
completely powered down and does not consume
any power� When on, the AI system increases power
consumption by approximately 10%�
Note that AI is never on when the Perdix 2 is turned
off�
More information about can be found in the AI Setup
section on page 65�
Pair the transmitter by going to the
Tx Setup
menu
option, and selecting T1� Turn on T1, then enter the
6-digit transmitter serial number into the
T1 Serial #
setting� You only need to set this once, as it will be
permanently saved in the settings memory�
AI Mode
Units
Tx Setup
GTR Mode
On
Bar
T1
Off
Next
Edit
AI Setup
#
On
Next
Edit
Transmitters
Serial
T1
On
285817
T2
Off
000000
T3
Off
000000
T4
Off
000000
Setup
T1 Serial#
Rated
Reserve
Rename
Unpair
285817
207
Bar
048
Bar
T1
Next
Edit
Tank Setup