background image

8

9

5. Install the tank back on the base of the 

unit. Make sure the tank is firmly seated.

Tank Cleaning

Remove the water tank from the unit by 
lifting it from main unit, then unscrew the 
tank cap; wipe the tank with a soft cloth 
then wash it with clean water.
Suggestion: Clean the water tank once 
every two to three weeks, depending on 
your water conditions.

Remove interior cover to access and 
clean Water Inlet and/or Ultrasonic 

Nebulizer.

1. Grasp tank and lift up from humidfier base.

2. Turn the tank upside down - remove the 

tank cap by turning it counterclockwise.

3. Fill the water tank with clean, cool 

 

tap water.

4. Replace the tank cap by turning 

clockwise until tight.

How to Fill

CAUTION:

 Before filling unit with water, turn power off and unplug unit from outlet.

Cleaning and Care

CAUTION:

 Before cleaning the unit, turn power off and unplug unit from outlet.

Summary of Contents for EV-HD10

Page 1: ...uct that requires modifications or adoption to enable it to operate in any other country than the country for which it was designed manufactured approved and or authorized or repair of products damaged by these modifications is not covered under this warranty THE WARRANTY PROVIDED HEREIN SHALL BE THE SOLE AND EXCLUSIVE WARRANTY THERE SHALL BE NO OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING ANY IM...

Page 2: ...g off parts or attachments Close supervision is necessary when this appliance is used by on or near children invalids or disabled persons Use this appliance only for its intended use as described in this manual Do not use attachments not recommended by The Sharper Image specifically any attachments not provided with the unit NEVER operate this appliance if it has a damaged cord or plug if it is no...

Page 3: ...ier in an environment where explosive gases are present Do not place the humidifier near heat sources such as a stove and do not expose the humidifier to the direct sunshine Always place the unit in the normal temperature environment to avoid excess damage Place the humidifier far away from furniture and home appliances Perform regular maintenance of the Ultrasonic Nebulizer Never put humidifier d...

Page 4: ...TENTION When the water in the water tank is almost empty the red indicator light will turn on and the power will shut off to indicate to the user to refill water Mist Adjustment Setting To increase the mist output turn the mist knob clockwise Night Light Press the night light button to turn on the night light The dial around the mist setting knob will light LOW WATER LEVEL EV HD10_Ultrasonic Cool ...

Page 5: ...ng on your water conditions Remove interior cover to access and clean Water Inlet and or Ultrasonic Nebulizer 1 Grasp tank and lift up from humidfier base 2 Turn the tank upside down remove the tank cap by turning it counterclockwise 3 Fill the water tank with clean cool tap water 4 Replace the tank cap by turning clockwise until tight How to Fill CAUTION Before filling unit with water turn power ...

Page 6: ...de the unit and damage will occur Ultrasonic Nebulizer Cleaning Put small amount of mild dish soap on the surface of the ultrasonic nebulizer then pour in some water and soak for 5 minutes then brush clean with soft bristle brush not included and rinse Surface Cleaning Clean the surface of the unit with a clean damp soft cloth Demineralization Cartridge The Sharper Image demineralization cartridge...

Reviews: